초록

Abstract

The purpose of this study was to assess the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to a friction-fit joint (Astra; Model 1) or slip- fit joint (Frialit-2; Model 2) in the internal connection system under vertical and inclined loading using finite element analysis. In conclusion, in the internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to the abutment connection form had difference among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the abutment post. The magnitude of the stress distributed in the supporting bone, the implant fixture, the abutment and the abutment screw was higher in the friction-fit joint than in the slip-fit joint. But it is considered that the further study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

참고문헌 (33)

  1. "Requirements for a reliable implant prosthetic treament concept tooth for tooth restoration", pp.1~18
  2. "Tissue-integrated prostheses complication", pp.477~484
  3. "Osseointegrated implants for single tooth replacement A 1-year report from a multicenter prospective study", pp.29~36
  4. "A multicenter retrospective analysis of ITI implant system used for single-tooth replacements Preliminary results at six or more months of loading", pp.237~242
  5. "Mechanics of the implant-abutment connection An 8-degree taper compared to a butt joint connection", pp.519~526
  6. "Finite element analysis of implant prostheis according to platform width of fixture", pp.674~688
  7. "Two-dimentional FEM analysis of hydroxyapatite implants diameter effects on stress distribution", pp.6~11
  8. "An experimental study on the tissue compatibility of the titanium blade-vent implant coated with HAP-alumina in the semi- functional state", pp.387~401
  9. "A study on the fit of the implant-abutment-screw interface", pp.503~518
  10. "A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges", pp.243~252
  11. "Load transfer from endosteal implants to supporting bone", pp.343~348
  12. "Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element", pp.450~458
  13. "Distribution of load in an oral orosthesis system an in vitro study", pp.552~560
  14. "Forces and moments on Branemark implants", pp.241~247
  15. "Load factor control for implants in the posterior partially edentulous segment", e(uard f), pp.360~370
  16. "A biomechanical rationale for the use of short implants", pp.126~131
  17. "Force distribution in splinted anterior teeth", pp.484~494 (1957)
  18. "Force distribution in splinted posterior teeth", pp.1268~1276 (1957)
  19. "The biomechanics of force distribution in implant- supported prostheses"
  20. "Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant"
  21. "A 3-year follow-up study of early single implant restorations ad modem Brå", pp.340~349, nemark
  22. "Failures and complications in 127 consecutive placed fixed partial prostheses supported by Branemark implants", pp.40~44
  23. "Comparison of strength and failure mode of seven implant systems An in vitro test", pp.582~591
  24. "Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants", pp.436~440
  25. "Evaluation of the mechanical characteristics of the implant abutment complex of a reduced diameter morse taper implant", pp.444~455
  26. "Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism", pp.3 239~245
  27. "An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design", pp.290~298
  28. "Assessment of cold welding properties of internal conical interface two commercially available implant system", pp.159~166
  29. "In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems", pp.567~571
  30. "The new concept of ITI hollow-cylinder and hollow-screw implants", pp.161~172 (1988)
  31. "The new restorative concept of the ITI dental implant system", pp.409~431
  32. "Comparative study of antirotational single tooth abutments", pp.36~43
  33. "Single-tooth replacement with frialit-2 system A retrospective clinical analysis of 146 implants", pp.78~85 (2002)

이 간행물의 다른 논문 (8건)