형광시약 Safranine-O를 이용한 유리 시안화 이온의 분광형광법 정량
Spectrofluorimetric determination of free cyanide ion with fluorescent safranine-O
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A spectrofluorimetric method has been developed for the determination of free CN− in real samples with fluorescent safranine-O. When safranine-O interacts electrostatistically with CN−, the fluorescent intensity of safranine-O is decreased. Several experimental conditions such as pH of the sample solution and the amount of safranine-O were optimized. Ag+ interfered higher than any other ions. Interference of Ag+ could be disregarded because Ag+ was scarcely contained or mostly complexed with CN− in selected real samples. With this proposed method, the linear range of CN− was from 5.0 to 110 ng/mL and the detection limit of CN−was 2.9 ng/mL. For validating this technique, real samples (Cu, Ag, Au electroplating wastewater, and untreated wastewater in university and in sewage treatment plant) were used. Recovery yields of 91.5%~106.0% were obtained. Based on experimental results, it is proposed that this technique can be applied to the practical determination of free CN−.
Abstract
A spectrofluorimetric method has been developed for the determination of free CN− in real samples with fluorescent safranine-O. When safranine-O interacts electrostatistically with CN−, the fluorescent intensity of safranine-O is decreased. Several experimental conditions such as pH of the sample solution and the amount of safranine-O were optimized. Ag+ interfered higher than any other ions. Interference of Ag+ could be disregarded because Ag+ was scarcely contained or mostly complexed with CN− in selected real samples. With this proposed method, the linear range of CN− was from 5.0 to 110 ng/mL and the detection limit of CN−was 2.9 ng/mL. For validating this technique, real samples (Cu, Ag, Au electroplating wastewater, and untreated wastewater in university and in sewage treatment plant) were used. Recovery yields of 91.5%~106.0% were obtained. Based on experimental results, it is proposed that this technique can be applied to the practical determination of free CN−.
참고문헌 (16)
- C. N Sawyer, "Chemistry for Environmental Engineering, 4th ed", pp.637~ (1996), McGraw-Hill
- D. Cacace, , Anal. Chim. Acta, 589, pp.137~141 (2007)
- S. Abbasi, , Spectrochim. Acta A, 77, pp.112~116 (2010)
- M. T. Fernndez-Argelles, , Anal. Chim. Acta, 491, pp.27~35 (2003)
- A. Safavi, , Anal. Chim. Acta, 503, pp.213~221 (2004)
- J. Lv, , Forensic Sci. Int, 148, pp.15~11 (2005)
- P. C. do Nascimento, , Talanta, 48, pp.341~346 (1999)
- K. Papeovand, , J. Chromatogr. A, 1120, pp.268~272 (2006)
- J. M. G. LaFuente, , Anal. Chim. Acta, 410, pp.135~142 (2000)
- B. Vallejo-Pecharromm, , Analyst, 127, pp.267~270 (2002)
- V. L. Gmez, , Analyst, 123, pp.2103~2107 (1998)
- D. L. Recalde-Ruiz, , Analyst, 125, pp.2100~2105 (2000)
- A. A. Ensafi, , Microchem. J, 72, pp.193~199 (2002)
- Z. Cao, , Talanta, 49, pp.377~383 (1999)
- G. D. Sharma, , Mater. Sci. Eng. B, 100, pp.13~17 (2003)
- M. L. Gmez, , Polymer, 44, pp.2875~2881 (2003)
