Abstract

Analysis of Implant Prosthesis using 2-Dimensional Finite Element Method Ho-Beom Kwon, Chan-Je Park, Seok-Hyoung Lee Department of Prosthodontics and Department of Conservative Dentistry*, Samsung Medical Center, Sungkyunkwan University School of Medicine Accurate fit of the implant prosthesis is important in ensuring long term success of osseointegrated implant. Inaccurate fit of the implant prosthesis may give rise to complications and mechanical failure. To evaluate fite of the implant prosthesis, the development of the methods of analyzing the degree of misfit is important in clinical practice. To analyze the degree of the misfit of implant prosthesis, modal testing was used. A 2-dimensional finite element modal testing was accomplished. Four 2-dimensional finite element models with various levels of misfit of implant prostheses were constructed. Thickness gauges were simulated to make misfit in the implant prostheses. With eigenvalue analysis, the natural frequencies of the models were found in the frequency domain representation of vibration. According to the difference of degree of misfit, natural frequencies of the models were changed.

참고문헌 (25)

  1. "Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws:A study of treatment from the time of prosthesis placement to the first annual checkup", 6, pp.270~276 (1991)
  2. "Alternative prosthodontic superstructure designs", 28, pp.71~75 (1985)
  3. "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", 10, pp.387~416 (1981)
  4. "Osseointegrated dental implants", 30, pp.151~174 (1986)
  5. "Prosthodontic problems and limitations associated with osseointegration", 79, pp.74~78 (1998)
  6. "Biomechanical considerations in osseointegrated prostheses", 49, pp.843~848 (1983)
  7. "Implant prosthodontics", 15, pp.66~75 (2000)
  8. "Osseous adaptation to continuous loading of rigid endosseous implants", 86, pp.95~111 (1984)
  9. "The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit", 76, pp.500~509 (1996)
  10. "Prosthesis misfit and marginal bone loss in edentulous implant patients", 11, pp.620~625 (1996)
  11. "Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years", 9, pp.169~178 (1994)
  12. "Tightening characteristics for screwed joints in osseointegrated dental implants", 71, pp.592~599 (1994)
  13. "Accuracy of implant-supported prostheses in the edentulous jaw", 6, pp.172~180 (1995)
  14. "In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw", 11, pp.151~158 (1996)
  15. "Fit of implant frameworks fabricated by different techniques", 78, pp.596~604 (1997)
  16. "Pulsed oscillation technique for assessing the mechanical state of the dental implant-bone interface", 12, pp.555~560 (1991)
  17. "A dynamic modal testing technique for noninvasive assessment of bone-dental implant interfaces", 11, pp.728~734 (1996)
  18. "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", 7, pp.261~267 (1996)
  19. "Assessing the implant", bone interface by using natural frequency analysis, 2000, pp.90, 285~291
  20. "Theory of vibration with applications", pp.128~135 (1997), Prentice Hall
  21. "Guidelines for analysis and redesign of dental implants", 7, pp.355~368 (1998)
  22. "The Korean Society of Noise and Vibration Engineering. Handbook of noise and vibration.", pp.279~291 (1995)
  23. "Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element:a finite element stress analysis", 7, pp.450~458 (1992)
  24. "Modal analysis and testing", 1989, pp.430~446
  25. "Impulse response of a dental implant in bone by numerical analysis", 18, pp.715~719 (1997)

관련 논문AI추천