논문KCI 등재
만곡 근관에서 다양한 엔진 구동형 Nickel-Titanium 파일의 근관 성형능력에 대한 연구
A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal
0
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
초록
Abstract
-A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal
참고문헌 (32)
- "Filling root canals in three dimensions", pp.723~744
- "Another look at root canal instrumentation", pp.499~507
- "Root canal morphology of the human mandibular first molar", pp.778~784
- "A comparison of canal preparation in straight and curved root canals", pp.271~275
- "An initial investigation of the bending and torsional properties of Nitinol root canal files", pp.346~351
- "A comparison of canal preparation with nickel-titanium and stainless steel instruments", 21, pp.173~176 (1995)
- "Profile을 이용한 만곡근관 형성시 근관형태에 관한 연구", 24, pp.633~637 (1999)
- "수종의 Engine-driven Ni-Ti file과 stainless steel K-file을 이용한 근관 형성 후 근관의 조직형태학적 변화에 대한 연구", 27, pp.612~621 (2002)
- Thompson SA, "Shaping ability of ProFile .04 taper series 29 rotary nickel-titanium instruments in simulated canals", 30, pp.1~7 (1997)
- Schafer E, "Shaping ability of Hero 642 rotaty nickel titanium instruments and stainless steel hand K-Flexofiles in simulated cureved root canals", 92, pp.215~220 (2001)
- Schafer E, "Efficiency of rotary nickel- titanium FlexMaster instruemts compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals", 35, pp.505~513 (2002)
- Peter OA., "Current challenges and conceptsin the preparation of root canal systems: a review", 30, pp.559~571 (2004)
- Schafer E, "Efficiency of rotary nickel- titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals", 36, pp.199~207 (2003)
- Schafer E, "Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals", 37, pp.229~238 (2004)
- Ayar LR, "Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in variable tip sequence in simulated curved root canals", 37, pp.593~601 (2004)
- Paqu F, "Comparison of root canal preparation using RaCe and ProTaper rotary Ni-Ti instruments", 38, pp.8~16 (2005)
- Rangel S, "Shaping ability of RaCe rotary nickel-titanium instruments in simulated root canal", 31, pp.460~463 (2005)
- Yoshimine Y, "The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals", 31, pp.373~375 (2005)
- "Shaping ability of GTTM Rotary Files in simulated resin root canals", 35, pp.607~614 (2002)
- "The effect of different files on the preparation shape of severely curved canals", pp.1~7
- "The validity of simulated root canals for the investigation of the prepared root canal shape", pp.240~246
- "Microscopic evaluation of three endodontic files pre and postinstumentation", 24, pp.461~464 (1998)
- "Shaping ability of Quantec Series 2000 rotary nickel-titanium instruments in simulated root canals", 31, pp.259~267 (1998)
- "Shaping ability of . 04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canal", 32, pp.155~164 (1999)
- "Canal shapes produced sequentially during instrumentation with Quantec LX rotary nickel-titanium instruments: a study in simulated canals", 33, pp.346~354 (2000)
- "A Comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals", 95, pp.228~233 (2003)
- "Change of Working length in curved canals by various instrumentation techniques", 31(1), pp.31~35 (2006)
- "Factors influencing the fracture of nickel titanium rotary instruments", 36, pp.262~266 (2003)
- "Defect in nickel titanium endodontic rotary files after clinical usage", 26, pp.161~165 (2000)
- "Cyclic fatigue testing of nickel-titanium endodontic instruments", 23, pp.77~85 (1997)
- "Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments", 25, pp.434~440 (1999)
- "Cyclic fatigue of ProFile rotary instruments after prolonged clinical use", 34, pp.386~389 (2001)
관련 논문AI추천
다양한 엔진 구동형 파일의 근관 성형 능력 비교허복, 박완기, 이희주대한치과보존학회 · Restorative Dentistry and Endodontics2004 · 제29권 제1호다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효육 비교허복, 김정원, 김현철, 박정길대한치과보존학회 · Restorative Dentistry and Endodontics2007 · 제32권 제6호만곡모형근관에서 초심자가 근관형성시 Ni-Ti 전동파일의 효용성김진우, 박세희, 조경모대한치과보존학회 · Restorative Dentistry and Endodontics2003 · 제28권 제2호수종의 엔진 구동형 니켈-타이타늄 합금파일의 절삭각에 따른 근관성형 효과에 관한 전자현미경적 연구금기연, 박성호, 윤태철, 전인수대한치과보존학회 · Restorative Dentistry and Endodontics2002 · 제27권 제6호학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교허복, 강문성, 김현철, 박정길대한치과보존학회 · Restorative Dentistry and Endodontics2006 · 제31권 제1호근단부 성형 크기에 따른 다양한 전동 니켈티타늄 파일의 중심 변위율 및 만곡도 감소 비교허복, 곽상원, 김현철, 박정길대한치과의사협회 · 대한치과의사협회지2009 · 제47권 제7호
이 간행물의 다른 논문 (8건)
불산 처리 시간이 IPS Empress? 2 세라믹의 2축 굴곡강도에 미치는 영향에 대한 연구이준석, 조인호, 신수연, 김연휘pp. 269-282이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCl의 영향에 대한 연구유미경, 이준봉, 박종덕, 이광원, 권수미pp. 283-292혈소판 유래 섬유소(Platelet Rich Fibrin(PRF))를 이용한 골결손부의 치료 : 증례보고고세욱, 지영덕pp. 303-312CT상의 HU 수치에 따른 유한요소모델을 이용한 RME 사용에 따른 응력분포에 대한 연구차경석, 정동화, 윤병선pp. 313-326이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I김용덕, 이주연, 허진호, 정창모, 김시엽, 김병국pp. 327-336