Bisphenols and phthalates are endocrine-disrupting chemicals that are commonly used in packaging and as plasticizers. However, they pose health risks through ingestion, inhalation, and dermal contact. Accurate analysis of these pollutants is challenging owing to their low concentration and their presence in complex oil matrices. Therefore, they require efficient extraction and detection methods. In this study, an analytical method for the simultaneous quantification of bisphenols and phthalates in corn oil is developed. The dynamic multiple reaction monitoring mode of liquid chromatography-tandem mass spectrometry is used according to the different polarities of bisphenols and phthalates. The method is validated by assessing system suitability, linearity, accuracy, precision, homogeneity, and stability. The determination coefficients are higher than 0.99, which is acceptable. The percentage recovery and coefficient of variation of the accuracy and precision confirm that this analytical method is capable of simultaneously quantifying bisphenols and phthalates in corn oil. The bisphenols and phthalates in the formulations and pretreatment samples are stable for 7 d at room temperature and 24 h in an auto-sampler. Therefore, this validated analytical method is effective for the simultaneous quantification of bisphenols and phthalates in oils.

Abstract

Bisphenols and phthalates are endocrine-disrupting chemicals that are commonly used in packaging and as plasticizers. However, they pose health risks through ingestion, inhalation, and dermal contact. Accurate analysis of these pollutants is challenging owing to their low concentration and their presence in complex oil matrices. Therefore, they require efficient extraction and detection methods. In this study, an analytical method for the simultaneous quantification of bisphenols and phthalates in corn oil is developed. The dynamic multiple reaction monitoring mode of liquid chromatography-tandem mass spectrometry is used according to the different polarities of bisphenols and phthalates. The method is validated by assessing system suitability, linearity, accuracy, precision, homogeneity, and stability. The determination coefficients are higher than 0.99, which is acceptable. The percentage recovery and coefficient of variation of the accuracy and precision confirm that this analytical method is capable of simultaneously quantifying bisphenols and phthalates in corn oil. The bisphenols and phthalates in the formulations and pretreatment samples are stable for 7 d at room temperature and 24 h in an auto-sampler. Therefore, this validated analytical method is effective for the simultaneous quantification of bisphenols and phthalates in oils.

참고문헌 (20)

  1. J. Pereira, , Food Control, 98, pp.54~60 (2019)[DOI]
  2. O. Ballesteros, , J. Chromatogr. A, 1121(2), pp.154~162 (2006)[DOI]
  3. H. T. Wan, , J. Hazard. Mater, 261, pp.763~769 (2013)[DOI]
  4. R. Babu-Rajendran, , J. Chromatogr. B, 1079, pp.15~24 (2018)[DOI]
  5. P. Viñas, , J. Chromatogr. A, 1376, pp.18~25 (2015)[DOI]
  6. E. Han, , Anal. Sci. Technol, 21(5), pp.375~382 (2008)
  7. S. López-Feria, , Anal. Bioanal. Chem, 395(3), pp.737~746 (2009)[DOI]
  8. M-H. Yoon, , Korean J. Sanitation, 20, pp.39~46 (2005)
  9. P. Gimeno, , J. Chromatogr. B, 949-950, pp.99~108 (2014)[DOI]
  10. H. Jung, , Environ. Toxicol. Pharmacol, 35(2), pp.278~283 (2013)[DOI]
  11. H-Y. Shen, , Talanta, 66(3), pp.734~739 (2005)[DOI]
  12. A. Vavrouš, , J. Chromatogr. A, 1456, pp.196~204 (2016)[DOI]
  13. M. Hyun, , Toxicology, 461, pp.152924~ (2021)[DOI]
  14. I. Lee, , J. Environ. Health Sci., 47(1), pp.1~19 (2021)[DOI]
  15. ICH Expert Working Group, "Validation of Analaytical Procedures: Text and Methodology Q2(R1), Version 4", ~ (2005)
  16. European Commission guidance document on analytical quality control and method validation procedures for pesticide residues and analysis in food and feed, "European Commission", ~, pp.SANTE (2017), 11813[DOI]
  17. B-C. Lee, , J. Ind. Eng. Chem, 99, pp.68~73 (2021)[DOI]
  18. N. Caballero-Casero, , Anal. Chim. Acta, 1144, pp.14~25 (2021)[DOI]
  19. N. Dreolin, , Food Chem, 274, pp.246~253 (2019)[DOI]
  20. L. K. Sosvorova, , Talanta, 174, pp.21~28 (2017)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (5건)