A Newly Designed 3-Dimensional Printer-Based Gastric Hemostasis Simulator with Two Modules for Endoscopic Trainees (with Video)
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background/Aims: We used 3-dimensional (3D) printing technology to create a new hemostasis simulator for the stomach and investigated its efficacy and realism in endoscopic hemostasis training. Methods: A new stomach hemostasis simulator, with two hemostasis modules for hemoclipping and injection, was constructed using a 3D printer. Twenty-one endoscopists, including 11 first-year fellows (beginner group) and 10 faculty members (expert group), tested the performance of the simulator. We recorded and reviewed five training sessions and evaluated the simulator with questionnaires using a 7-point Likert scale. Results: The mean evaluation score of the expert group was 6.3±0.5 for the hemoclipping module and 6.0±0.6 for the injection module. The expert group strongly agreed that endoscopic handling in the simulator was realistic and reasonable for hemostasis training. The mean procedure time for hemoclipping was 72.7±7.1 seconds for the beginner group and 19.7±1.2 seconds for the expert group. The mean procedure time for injection was 92.1±9.8 seconds for the beginner group and 36.3±2 seconds for the expert group. The procedure time of beginner group became shorter with repetition and was significantly lower by the fifth trial. Conclusions: A new 3D-printed hemostasis simulator is capable of hemostasis training and can very effectively train beginners before they perform the procedure in patients with gastrointestinal bleeding.
Abstract
Background/Aims: We used 3-dimensional (3D) printing technology to create a new hemostasis simulator for the stomach and investigated its efficacy and realism in endoscopic hemostasis training. Methods: A new stomach hemostasis simulator, with two hemostasis modules for hemoclipping and injection, was constructed using a 3D printer. Twenty-one endoscopists, including 11 first-year fellows (beginner group) and 10 faculty members (expert group), tested the performance of the simulator. We recorded and reviewed five training sessions and evaluated the simulator with questionnaires using a 7-point Likert scale. Results: The mean evaluation score of the expert group was 6.3±0.5 for the hemoclipping module and 6.0±0.6 for the injection module. The expert group strongly agreed that endoscopic handling in the simulator was realistic and reasonable for hemostasis training. The mean procedure time for hemoclipping was 72.7±7.1 seconds for the beginner group and 19.7±1.2 seconds for the expert group. The mean procedure time for injection was 92.1±9.8 seconds for the beginner group and 36.3±2 seconds for the expert group. The procedure time of beginner group became shorter with repetition and was significantly lower by the fifth trial. Conclusions: A new 3D-printed hemostasis simulator is capable of hemostasis training and can very effectively train beginners before they perform the procedure in patients with gastrointestinal bleeding.
참고문헌 (19)
- Quan S, "Upper-gastrointestinal bleeding secondary to peptic ulcer disease : incidence and outcomes", World J Gastroenterol, 20, pp.17568~17577 (2014)
- Lu Y, "Adherence to guidelines: a national audit of the management of acute upper gastrointestinal bleeding. The REASON registry", Can J Gastroenterol Hepatol, 28, pp.495~501 (2014)
- Marmo R, "Dual therapy versus monotherapy in the endoscopic treatment of high-risk bleeding ulcers : a meta-analysis of controlled trials", Am J Gastroenterol, 102, pp.279~289 (2007)
- Yuan Y, "Endoscopic clipping for acute nonvariceal upper-GI bleeding : a meta-analysis and critical appraisal of randomized controlled trials", Gastrointest Endosc, 68, pp.339~351 (2008)
- Sedlack RE, "Computer simulator training enhances the competency of gastroenterology fellows at colonoscopy : results of a pilot study", Am J Gastroenterol, 99, pp.33~37 (2004)
- "Product brochure" (2016)[URL]
- "Product brochure" (2017)[URL]
- Pinkas H, "Prolonged evaluation of epinephrine and normal saline solution injections in an acute ulcer model with a single bleeding artery", Gastrointest Endosc, 42, pp.51~55 (1995)
- Michaletz PA, "Microwave energy compared with heater probe and BICAP in canine models of peptic ulcer hemorrhage", Gastroenterology, 97, pp.676~684 (1989)
- Chou YC, "A prospective, randomized trial of endoscopic hemoclip placement and distilled water injection for treatment of high-risk bleeding ulcers", Gastrointest Endosc, 57, pp.324~328 (2003)
- Matthes K, "Simulator training in endoscopic hemostasis", Tech Gastrointest Endosc, 13, pp.174~182 (2011)
- Hu B, "Eagle Claw II : a novel endosuture device that uses a curved needle for major arterial bleeding : a bench study", Gastrointest Endosc, 62, pp.266~270 (2005)
- Neumann M, "Part 1. The Erlanger endo-trainer", Endoscopy, 33, pp.887~890 (2001)
- Hochberger J, "Training simulators and education in gastrointestinal endoscopy : current status and perspectives in 2001", Endoscopy, 33, pp.541~549 (2001)
- Triantafyllou K, "Virtual reality simulators for gastrointestinal endoscopy training", World J Gastrointest Endosc, 6, pp.6~12 (2014)
- AbouHashem Y, "The application of 3D printing in anatomy education", Med Educ Online, 20, pp.29847~ (2015)
- Tack P, "3D-printing techniques in a medical setting : a systematic literature review", Biomed Eng Online, 15, pp.115~ (2016)
- Sunpyo Lee, "Efficacy of a Three-Dimensional-Printed Training Simulator for Endoscopic Biopsy in the Stomach", Gut and Liver, 12(2), pp.149~157 (2018), 거트앤리버 소화기연관학회협의회
- Ji Yong Ahn, "The Efficacy of a Newly Designed, Easy-to-Manufacture Training Simulator for Endoscopic Biopsy of the Stomach", Gut and Liver, 10(5), pp.764~772 (2016), 거트앤리버 소화기연관학회협의회
