논문KCI 등재
기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템
Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve
2
조회
0
다운로드
1
인용
0
참고문헌
참고문헌 (24)
- "“인공장기”," (1994), 서울대학교 출판부
- "Edmunds L. Henry Jr. “Thromboembolic complications of current cardiac valvular prosthesis”", 34, pp.96~106 (1982)
- "“Thrombosis of prosthetic heart valves: diagnosis and management”,", 87(4), pp.20~32 (1998)
- "“Guidelines for Reporting Morbidity and Mortality after Cardiac Valvular Operations”", 112(3), pp.708~711 (1996)
- "“Obstruction of mechanical heart valve prosthesis", 17, pp.6462~ (1991)
- "Prosthetic valve thrombosis", 4, pp.141~153 (1995)
- "“Obstruction of mechanical valve prostheses clinical diagnosis and surgical or nonsurgical treatment”", 26, pp.400~6 (1996)
- "“Thrombolytic therapy of left-sided prosthetic valve thrombosis”", 108, pp.1683~1689 (1995)
- "Evaluation of FFT-based and modern parametric methods for the spectral analysis of bioprosthetic valve sounds", 33(6), pp.572~578 (1986)
- "Detection of Aortic Porcine Valve Dysfunction by Maximum Entropy Spectral Analysis", 68, pp.42~49 (1983)
- "“Classification of prosthetic heart valve sounds: A parametric approach”,", 97, pp.3675~3687 (1995)
- "Spectral Composition of Heart Sounds Before and After Mechanical Heart Valve Implantation Using a Modified Forward-Backward Prony's Method", 43(7), pp.734~742 (1996)
- "Performance Evaluation of Implantable Artificial Organs by Sound Spectrum Analysis", 40, pp.762~766 (1994)
- "“Noninvasive Diagnosis of Mechanical Failure of the Implanted Total Artificial Heart Using Neural Network Analysis of Acoustic Signals”", 41, pp.271~276 (1995)
- "“Diagnosis of prosthetic heart valve thrombosis” The respective values of transthoracic and transesophageal Doppler echocardiography. Eur Heart J. Vol. 14", pp.447~455 (1993)
- "“In-Vitro Thrombosis Detection of Mechanical valve Using Artificial Neural Network”", 18(4), pp.429~438 (1997)
- "Real-time sound spectroanalysis for diagnosis of malfunctioning prosthetic valves", 79, pp.671~679 (1980)
- "Linear and Nonlinear ARMA Model Parameter Estimation Using an Artificial Neural Network", 44(3), pp.168~174 (1997)
- "“Comparison of Pattern Recognition Method for Computer Assisted Classification of Spectra of Heart Sounds in Patient with a Porcine Bioprosthetic Valve Implanted in the Mitral 1. 1. 1. Position”", 37(12), pp.1121~1129 (1990)
- "“In Vivo Testing of a Completely Implantable Total Artificial heart System”", 39, pp.177~184 (1993)
- "“소아환자에서 St. Jude Medical 인공판막의 혈전현상”", 24, pp.88~92 (1991)
- "“Non-invasive Acoustical Evaluation of the Utah Electrohydraulic Total Artificial Heart”", 23, pp.7~ (1994)
- "“Universal approximation bounds for superpositions of a sigmoidal function” IEEE Trans. on Information Theory", 39, pp.930~945 (1993)
- "“Universal approximation bounds for superpositions of a sigmoidal function” IEEE Trans. on Information Theory", 39, pp.930~945 (1993)
관련 논문AI추천
Study on the Diagnosis of Abnormal Prosthetic Valve이혁수한국융합신호처리학회 · 융합신호처리학회 논문지2013 · 제14권 제1호공압식 심실보조장치의 in-vivo 평가 및 내구성 개선강봉진, 김삼현, 박성식, 서필원, 이광호, 이상훈대한의용생체공학회 · 의공학회지2004 · 제25권 제1호Ergodic Hidden Markov Model을 이용한 연속심음분류에 관한 연구김희근, 정용주대한의료정보학회 · Healthcare Informatics Research2007 · 제13권 제1호신호 특성을 고려한 가변 상태 개수 HMM을 이용한 심음분류 방법에 대한 고찰정용주대한의료정보학회 · Healthcare Informatics Research2008 · 제14권 제2호심음구분을 위한 어트랙터 구성방법이 프랙탈 차원에 미치는 영향김태식, 김혜영, 이영신대한의료정보학회 · Healthcare Informatics Research2004 · 제10권 제2호기계식 인공 판막 주위의 유연성 구조가 표면 괴식에 미치는 영향선경, 이환성, 황성원대한의용생체공학회 · 의공학회지2002 · 제23권 제4호
이 간행물의 다른 논문 (12건)
3차원 MR 영상으로부터의 한국인 뇌조직확률지도 개발김인영, 김현필, 구방본, 윤의철, 이종민, 김정현, 김선일, 권준수, 이동수pp. 1-1센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상양윤석pp. 2-2유방암 검출을 위한 생체 어드미턴스 스캐너의 개발이재상, 오동인, 이정환, 우응제, 권오인, 서진근pp. 3-3전기성문전도(EGG) 시스템의 개발 및 평가이승훈, 정동근, 전계록, 김기련, 최병철, 김광년, 왕수건, 허승덕pp. 4-4속도 계측형 호흡기류센서 설계를 위한 비균등 샘플링 기법차은종, 김경아, 이태수pp. 5-5