뇌자도에서 전체 평균과 이를 이용한 해부학적 위치 추정
Grand Average in MEG and Crude Estimation of Anatomical Site
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this work, a method is presented to find an anatomical site of a current source crudely in a standard brain using grand average of MEG data. Minimum norm estimation algorithm and truncated singular value decomposition were applied to calculate the distributed sources that can reproduce the measured signals. Grand average over all subjects was obtained from the transformed signals, which would be detected in a standard sensor plane by the obtained distributed current sources. In the simulation study, it was shown that the localized dipole using the grand average is consistent with the mean location of localized dipoles of all subjects within several mm even with large inter-individual differences of sensor positions. This result suggests that the mean location of low level signal source can be estimated as a dipole source in grand average and it was confirmed in the localization of the current source of N100m. when the localized dipole is registered on a standard brain. This result also suggests that the activity region obtained from grand average can be crudely estimated on a standard brain using the source location of the N100m as a reference point.
Abstract
In this work, a method is presented to find an anatomical site of a current source crudely in a standard brain using grand average of MEG data. Minimum norm estimation algorithm and truncated singular value decomposition were applied to calculate the distributed sources that can reproduce the measured signals. Grand average over all subjects was obtained from the transformed signals, which would be detected in a standard sensor plane by the obtained distributed current sources. In the simulation study, it was shown that the localized dipole using the grand average is consistent with the mean location of localized dipoles of all subjects within several mm even with large inter-individual differences of sensor positions. This result suggests that the mean location of low level signal source can be estimated as a dipole source in grand average and it was confirmed in the localization of the current source of N100m. when the localized dipole is registered on a standard brain. This result also suggests that the activity region obtained from grand average can be crudely estimated on a standard brain using the source location of the N100m as a reference point.
참고문헌 (11)
- "instrumentation and applications to the noninvasive studies of the working human brain", 65, pp.413~497 (1993)
- "Left Temporal and Temporoparietal Brain Activity Depends on Depth of Word Encoding Magnetoencephalographic study in healthy young subjects", 13, pp.402~409 (2001)
- "Transformation of multichannel magnetocardiographic signals to standard grid form", 42, pp.72~78 (1995)
- "Transformation of whole-head MEG recordings between different sensor positions", 47, pp.59~62 (2002)
- "Construction of a 40 channel SQUID system and Its application to neuromagnetic measurements Progress in Superconductivity", 2, pp.20~26 (2000)
- "심자도를 이용한 심근 전류분포 복원과 임상적 응용", 24(5), pp.459~464 (2003)
- "Localization accuracy of single current dipoles from tangential components of auditory evoked fields", 47, pp.4145~4154 (2002)
- "Interpreting magnetic fields of the brain", minimum 32(rm estimates), pp.35~42 (1994)
- "norm estimation in a boundary element torso model", 32, pp.43~48 (1994)
- "Enhancement of mr imagies using registration for signal averaging", 22, pp.455~462 (2000)
- "Enhancement of mr imagies using registration for signal averaging", 22, pp.455~462 (2000)