저주파/고주파와 냉자극을 이용한 의료용 조합 자극기의 설계 및 구현
Design and Implementation of Medical Compound Stimulator Using Low/High Frequency and Cooling Stimulation
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of 0 ~ 20℃ and the verified low and high frequencies of 250 Hz, 500 Hz, 1 KHz and 1 MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients’ treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.
Abstract
In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of 0 ~ 20℃ and the verified low and high frequencies of 250 Hz, 500 Hz, 1 KHz and 1 MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients’ treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.
참고문헌 (7)
- Mitragotri S, "Healing sound: the use of ultrasound in drug delivery and other therapeutic applications", pp.255~260 (2005), Nat Rev Drug Discov
- Lavon I, "Ultrasound and transdermal drug delivery", pp.670~676 (2004), Drug Discov Today
- A. Aloisi, "Cryoelectrophoresis: Painless administration of drugs through a suitable association of thermal and electrical techniques", AIP Conference Processing, 513, pp.19~22 (2000)
- Carruthers A, "Radiofrequency resurfacing: Technique and clinical review", pp.311~319 (2001), Facial Plast Surg Clin N Am
- R. Venkatasubramanian, "Thin-film thermoelectric devices with high room-temperature figures of merit", pp.413~597 (2001), Nature.
- 강병하, "열전모듈을 이용한 에어컨의 방열부 냉각특성에 대한 연구", 설비공학 논문집, 14(3), pp.4~482 (2002), 대한설비공학회
- Yang, Y. S, "R & D trend on the thermoelectric energy conversion technology", Korea J. of Air-Conditioning and Refrigeration Engineering, 23(5), pp.362~402 (1994)