무릎 연골 두께 아틀라스를 통한 손상 평가 기법
Knee Cartilage Defect Assessment using Cartilage Thickness Atlas
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Osteoarthritis is the most common chronic joint disease in the world. With its progression, cartilage thickness tends to diminish, which causes severe pain to human being. One way to examine the stage of osteoarthritis is to measure the cartilage thickness. When it comes to inter-subject study, however, it is not easy task to compare cartilage thickness since every human being has different cartilage structure. In this paper, we propose a method to assess cartilage defect using MRI inter-subject thickness comparison. First, we used manual segmentation method to build accurate atlas images and each segmented image was labeled as articular surface and bone-cartilage interface in order to measure the thickness. Secondly, each point in the bone-cartilage interface was assigned the measured thickness so that the thickness does not change after registration. We used affine transformation and SyGN to get deformation fields which were then applied to thickness images to have cartilage thickness atlas. In this way, it is possible to investigate pixel-by-pixel thickness comparison. Lastly, the atlas images were made according to their osteoarthritis grade which indicates the degree of its progression. The result atlas images were compared using the analysis of variance in order to verify the validity of our method. The result shows that a significant difference is existed among them with p < 0.001.
Abstract
Osteoarthritis is the most common chronic joint disease in the world. With its progression, cartilage thickness tends to diminish, which causes severe pain to human being. One way to examine the stage of osteoarthritis is to measure the cartilage thickness. When it comes to inter-subject study, however, it is not easy task to compare cartilage thickness since every human being has different cartilage structure. In this paper, we propose a method to assess cartilage defect using MRI inter-subject thickness comparison. First, we used manual segmentation method to build accurate atlas images and each segmented image was labeled as articular surface and bone-cartilage interface in order to measure the thickness. Secondly, each point in the bone-cartilage interface was assigned the measured thickness so that the thickness does not change after registration. We used affine transformation and SyGN to get deformation fields which were then applied to thickness images to have cartilage thickness atlas. In this way, it is possible to investigate pixel-by-pixel thickness comparison. Lastly, the atlas images were made according to their osteoarthritis grade which indicates the degree of its progression. The result atlas images were compared using the analysis of variance in order to verify the validity of our method. The result shows that a significant difference is existed among them with p < 0.001.
참고문헌 (13)
- D. T. Felson, "The incidence and natural history of knee osteo-arthritis in the elderly", Arthritis &Rheum, 38, pp.1500~1505 (1995)
- F. Eckstein, "Quantitative MRI of cartilage and bone: degenerative changes in osteoarthritis", NMR in Biomedicine, 19, pp.822~854 (2006)
- J. H. Kellgren, "Radiological Assessment of Osteo-Arthrosis", Annals of the rheumatic diseases, 16, pp.494~502 (1957)
- Sonka, Milan, "Handbook of medical imaging", SPIE- The international society for optical engineering, 452~455 (2004)
- J. Goldenstein, "Prospective image registration for automated scan prescription of follow-up knee images in quantitative studies", Magnetic Resonance Imaging, 29, pp.693~700 (2011)
- J. C-Gamio, "Inter-subject comparison of MRI knee cartilage thickness", Medical Image Analysis, 12, pp.120~135 (2008)
- J. C-Gamio, "Atlas-based knee cartilage assessment", Magnetic Resonance in Medicine, 66, pp.574~583 (2011)
- B. B. Avants, "Symmetric diffeomorphic image registration with crosscorrelation:Evaluating automated labeling of eldery and neurodegenerative brain", Medical Image Analysis, 12, pp.26~41 (2008)
- T. G. Williams, "Measurement and visualization of focal cartilage thickness change by MRI in a study of knee osteoarthritis using a novel image analysis tool", The British Journal of Radiology, 83, pp.940~948 (2010)
- S. Balamoody, "Comparison of 3T MR scanners in regional cartilage-thickness analysis in osteoarthritis:a cross-sectional multicenter, multivendor study", Arthritis Research and Therapy, 12 (2010)
- A. Klein, "Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration", NeuroImage, 46, pp.786~802 (2009)
- B. B. Avants, "The optimal template effect in hippocampus studies of diseased populations", NeuroImage, 49, pp.2457~2466 (2010)
- B. B. Avants, "A reproducible evaluation of ANTs similarity metric performance in brain image registration", NeuroImage, 54, pp.2033~2044 (2011)