저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향

The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power con- sumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through exper- iments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that inter- mittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

Abstract

Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power con- sumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through exper- iments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that inter- mittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

참고문헌 (20)

  1. 박영상, "유헬스케어 패치형 무선 체온 모니터링 시스템 구현", 의공학회지, 41(1), pp.55~61 (2020), 대한의용생체공학회
  2. Islam SR, "The internet of things for health care: a comprehensive survey", IEEE access, 3, pp.678~708 (2015)
  3. Pang Z, "Technologies and Architectures of the Internet-of-Things (IoT) for Health and Well-being", Doctor, pp.2013
  4. Polonelli T, "A multi-protocol system for configurable data streaming on IoT healthcare devices", 2019 IEEE 8th International Workshop on Advances in Sensors and Interfaces (IWASI), pp.112~117 (2019)
  5. Lee HJ, "Ubiquitous healthcare service using Zigbee and mobile phone for elderly patients", International journal of medical informatics, 78(3), pp.193~198 (2009)
  6. Lee JS, "A comparative study of wireless protocols: Bluetooth, UWB, ZigBee, and Wi-Fi", IECON 2007-33rd Annual Conference of the IEEE Industrial Electronics Society, pp.46~51 (2007)
  7. Khriji S, "Women in Precision Agriculture", pp.107~129 (2021), Springer
  8. 백현재, "반지 형태의 웨어러블 헬스케어 디바이스 개발", 전기학회논문지, 67(7), pp.892~897 (2018), 대한전기학회
  9. Lin ZM, "Bluetooth Low Energy (BLE) based blood pressure monitoring system", 2014 International Conference on Intelligent Green Building and Smart Grid (IGBSG), pp.1~4 (2014)
  10. "GLS_SPEC_V10", Bluetooth SIG, 9~ (2012)
  11. "HRS_SPEC_V10", Bluetooth SIG, 9~ (2011)
  12. "HTS_SPEC_V10", Bluetooth SIG, 9~ (2011)
  13. "의료기기 품목 및 품목별 등급에 관한 규정", 식품의약품안전처고시 제2021-24호: 식품의약품안전처, ~ (2021)
  14. "의료기기 기준규격", 식품의약품안전처고시 제2021-3호: 식품의약품안전처, ~ (2021)
  15. "무선심전계시스템 동등제품공고", 식품의약품안전처, ~ (2017)
  16. Gomez C, "Overview and evaluation of bluetooth low energy: An emerging low-power wireless technology", Sensors, 12(9), pp.11734~11753 (2012)
  17. 무선 설비 적합성 평가 시험방법, , 방송통신표준심의회, ~ (2020)
  18. Kim G, "A Study of BLE Mesh Network Scheduling Algorithm Using A Smartplug", Turkish Journal of Computer and Mathematics Education (TURCOMAT), 12(6), pp.456~451 (2021)
  19. "유헬스케어 의료기기 시스템 허가심사 가이드라인", 식품의약품안전처, ~ (2016)
  20. "유헬스케어 의료기기 품목별 허가심사 가이드라인", 식품의약품안전처, ~ (2016)

관련 논문AI추천

이 간행물의 다른 논문 (5건)