논문KCI 등재
Performance Enhancement of Ultrasonic Sensitivity by Improving the Transmitter Circuit
0
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
We have developed the spirometer system; many patients having weak respiration have difficulties in using conventional spirometers in hospitals, because their weak breath can be affected by the errors of inertia and instrumental pressure. We have developed a new ultrasound spirometer using an ARM 920T processor. To detect weak respiratory signals, we add a comparator circuit, which can afford more information of respiration characteristics such as respiration volume, directions, and velocities. We have also developed GUI for graphical display of respiration characteristics. Through the pilot test, it has been verified that the developed spirometer is operating reliably.
참고문헌 (9)
- "A Method for Calculating Acoustic Fields in a Finite Cylindrical Channel with a Flow", 44(1) (1998)
- "Medical Instrumentation Application and Design" (1998)
- "Official Statement of the European Respiratory Society Standardization of Lung Function Tests European Community for Steel and Coal. European Respiratory Journal", 6, pp.16 5~40 (1993)
- "Lung volumes and forced ventilator flows. Report working party on Standardization of Lung Function tests", 6(16), pp.5~40 (1993)
- "The contribution of respiratory function tests in clinical diagnosis", pp.983~990 (1993)
- "Phase Method of Acoustic Anemometry", no. 7, pp.39~43 (1990)
- "Quantitative assessment of the value of spirometry Standardization of spirometry", pp.360 1107~363 1136 (1994)
- "Flux Measurement A to Z", pp.1997~
- "Sensitivity Enhancement of Spirometer Employing Ultrasonic Method", 26(6), pp.351~356 (2005)
관련 논문AI추천
Sensitivity Enhancement of Spirometer Employing Ultrasonic MethodSeung Heon Han, Young Kil Kim대한의용생체공학회 · 의공학회지2005 · 제26권 제6호A Programmable Pulser-Receiver Circuit for Single Transducer Medical Ultrasound System박현태, 엄지용반도체설계교육센터 · IDEC Journal of Integrated Circuits and Systems2021 · 제7권 제4호압전 횡효과를 이용한 무지향성 주파스가변 초음파트랜스듀서강갑중, 김무준, 김정순, 하강렬한국센서학회 · 센서학회지2004 · 제13권 제6호Improving sensitivity of SAW-based pressure sensor with metal ground shielding over cavity김근영, 양상식, 이기근, 황정수, Wen Wang한국마이크로전자및패키징학회 · 마이크로전자 및 패키징학회지2005 · 제12권 제3호A reconfigurable ultrasonic analog front-end IC for medical imaging applications차혁규, Fatia Uftiani Putri반도체설계교육센터 · IDEC Journal of Integrated Circuits and Systems2018 · 제4권 제2호An Efficient Focusing Method for High Resolution Ultrasound ImagingKang-Sik Kim대한의용생체공학회 · 의공학회지2006 · 제27권 제1호
이 간행물의 다른 논문 (6건)
A Study of Design of Hollow Fiber Membrane Modules for using in Artificial Lung by the PZT actuatorMin Ho Kim, Yong Chul Lee, Chul Un Hong, Seong Jong Kim, Gi Beum Kimpp. 143-153A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric ActivityIn-Seon Kim, Yong-Ki Park, 김기웅, Yong-Ho Lee, Jin-Mok Kim, Hyukchan Kwon, Kwon-Kyu Yupp. 154-163An Extensive Analysis of High-density Electroencephalogram during Semantic Decision of Visually Presented WordsJa Hyun Kim, 김경환pp. 170-179Design of Bristle Shapes using 3-dimensional Teeth Data for the Periodontally Involved PatientsJong-Hyun Bae, 서명원, 김현준pp. 180-188Zoom-in Micro-tomography와 3차원 Fuzzy Distance Transform을 이용한 쥐 대퇴부의 해면골 두께 측정이수열, 조민형, Jeong Jin Parkpp. 189-196