디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography

0

조회

0

다운로드

3

인용

0

참고문헌

초록

Abstract

For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of Min-RTM screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

참고문헌 (45)

  1. R.A. Street, "Amorphous silicon sensor arrays for radiation imaging", 192, pp.441~452 (1990)
  2. J.A. Rowlands, "Amorphous semiconductor usher in digital x-ray imaging", 50, pp.24~30 (1997)
  3. H.K. Kim, "Use of a flat-panel detector for microtomography A feasibilitystudy for small-animal imaging", 52(1), pp.193~198 (2005)
  4. H.K. Kim, "Sensor technology for digital radiography", 22(8), pp.7~16 (2005)
  5. M. Bigas, "Review of CMOS image sensors", 37, pp.433~451 (2006)
  6. D.A. Jaffray, "Cone-beam computed tomography with a flat-panel imager: Initial performance characterization", 27, pp.1311~1322 (2000)
  7. R. Ning, "Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation", 19, pp.949~963 (2000)
  8. S.C. Lee, "A flat-panel detector based micro-CT system: Performance evaluation for small-animal imaging", 48, pp.4173~4185 (2003)
  9. J.M. Boudry, "Radiation damage of amorphous silicon photodiode sensors", 41, pp.703~707 (1994)
  10. J.M. Boudry, "Radiation damage of amorphous silicon, thin-film, field-effect transistors", 23, pp.743~754 (1996)
  11. B.H. Hasegawa, "The Physics of Medical X-ray Imaging" (1991)
  12. I.A. Cunningham, "Applied linear-systems theory" (2000), USA: SPIE Press
  13. J.T. Dobbins III, "Image quality metrics for digital systems" (2000), USA: SPIE Press
  14. J.-M. Kim, "Investigation of scintillation screens for x-ray imaging", 321-323, pp.1056~1059 (2006)
  15. T. Graeve, "High-resolution CMOS imaging detector", 4320, pp.68~76 (2001)
  16. T.R. Oldham, "Total ionizing dose effects in MOS oxides and devices", 50, pp.483~499 (2003)
  17. H.J. Barnaby, "Total-ionizing-dose effects in modern CMOS technologies", 53, pp.3103~3121 (2006)
  18. W. Zhao, "Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors", 4682, pp.9~20 (2002)
  19. T. Stanescu, "Sensitivity reduction in biased amorphous selenium photoconductors", 35, pp.2716~2722 (2002)
  20. A.W. Rau, "The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers", 32, pp.3160~3177 (2005)
  21. M. Zahangir Kabir, "Sensitivity of stabilized a-Se based x-ray photoconductors", 6, pp.393~398 (2006)
  22. J.H. Siewerdsen, "A ghost story: Spatio- temporal response characteristics of an indirect-detection flat-field imager", 26, pp.1624~1641 (1999)
  23. H.K. Kim, "Analytic model for incomplete signal generation in semiconductor detectors", 88, pp.112~132 (2006)
  24. W.R. Dawes Jr, "Radiation effects hardening techniques" (1985)
  25. E. Samei, "Image quality in two phosphor-based flat panel digital radiographic detectors", 30, pp.1747~1757 (2003)
  26. E. Samei, "An experimental comparison of detector performance for direct and indirect digital radiography systems", 30, pp.608~622 (2003)
  27. E. Samei, "Intercomparison of methods for image quality characterization. I. Modulation transfer function", 33, pp.1454~1465 (2006)
  28. H. Fujita, "A simple method for determining the modulation transfer function in digital radiography", 11, pp.34~39 (1992)
  29. J.T. Dobbins III, "Effects of undersampling on the proper interpretation of modulation transfer function and noise equivalent quanta of digital imaging systems", 22, pp.171~181 (1995)
  30. J.T. Dobbins III, "DQE(f) of four generations of computed radiography acquisition devices", 22, pp.1581~1593 (1995)
  31. J.T. Dobbins III, "Intercomparison of methods for image quality characterization. II. Noise power spectrum", 33, pp.1466~1475 (2006)
  32. M.J. Flynn, "Experimental comparison of noise and resolution for 2k and 4kstorage phosphor radiography systems", 26, pp.1612~1623 (1999)
  33. M.K. Cho, "Charac- terization of CMOS pixel detectors for digital x-ray imaging", 321-323, pp.1052~1055 (2006)
  34. C.-S. Kim, "Computational toolset for x-ray spectral analysis", . 321-323, pp.1060~1065 (2006)
  35. H.K. Kim, "Generalized cascaded model to assess noise transfer in scintillator-based x-ray imaging detectors", 89, pp.233~504 (2006)
  36. J.H. Siewerdsen, "Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology", 24, pp.71~89 (1997)
  37. J.H. Siewerdsen, "Signal, noise power spectrum and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology", 25, pp.614~628 (1998)
  38. J. Yao, "Parallel cascades: New ways to describe noise transfer in medical imaging systems", 28, pp.2020~2038 (2001)
  39. "The effect of phosphor K x-rays on the MTF of rare-earth screens", 6, pp.500~503 (1979), B.A. Arnold and B.E. Bjarngard
  40. R.K. Swank, "Absorption and noise in x-ray phosphors", 44, pp.4199~4203 (1973)
  41. G. Cho, "Monte Carlo analyses of x-ray absorption, noise, and detective quantum efficiency considering therapeutic x-ray spectrum in portal imaging detector", 18, pp.1423~1427 (2001)
  42. K.-W. Jee, "System performance of a prototype flat-panel imager operated under mammographic conditions", 30, pp.1874~1890 (2003)
  43. H.K. Kim, "Monte Carlo studies of metal", phosphor screen in therapeutic x-ray imaging, 1999., pp.422, 713~717
  44. W. Zhao, "Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency", 24, pp.1819~1833 (1997)
  45. J. Bogaerts, "Total dose effects on CMOS active pixel sensors", 3965, pp.157~167 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (16건)