위전도 측정을 위한 전극간 부착거리에 관한 연구
Influences of Inter-electrode Distance on Electrogastrography Measurements
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Cutaneous electrogastrography is the measurement of electrical activity of the stomach on the abdominal surface. The validity of cutaneous electrogastrography is dependent upon the quality of the recording technique. The locations of electrodes are an important issue. We examined the influences of the inter-electrode distance of bipolar leads on electrogastrography measurements. The sensitivity distributions of EGG leads were calculated based on a 2D body fat model and evaluated according to the region of interest sensitivity ratio (ROISR). We simulated the ROISR of the inter-electrode distance in relation to various body fat thicknesses. The distance between the electrodes was proportional to the distance between the ROI and the surface of the abdomen. The results imply that inter-electrode distance can be applied in electrogastrography according to human body fat thickness.
Abstract
Cutaneous electrogastrography is the measurement of electrical activity of the stomach on the abdominal surface. The validity of cutaneous electrogastrography is dependent upon the quality of the recording technique. The locations of electrodes are an important issue. We examined the influences of the inter-electrode distance of bipolar leads on electrogastrography measurements. The sensitivity distributions of EGG leads were calculated based on a 2D body fat model and evaluated according to the region of interest sensitivity ratio (ROISR). We simulated the ROISR of the inter-electrode distance in relation to various body fat thicknesses. The distance between the electrodes was proportional to the distance between the ROI and the surface of the abdomen. The results imply that inter-electrode distance can be applied in electrogastrography according to human body fat thickness.
참고문헌 (20)
- W.C. Alvarez, "The electrogastrogram and what it shows", JAMA, 78, pp.1116~1118 (1922)
- F.Y. Chang, "Electrogastrography: Basic knowledge, recording, processing and its clinical applications", J. of Gastroenterology and Hepatology, 20, pp.502~516 (2005)
- Z.S.Wang, "Chaotic Behavior of Gastric Migrating Myoelectrical Complex", IEEE trans. on biomed. Eng, 51, pp.1401~1406 (2004)
- M. Bortolotti, "Electrogastrography: A seductive promise, only partially kept", Am. J. of Gastro, 93(10), pp.1791~1794 (1998)
- P. Camborova, "The Pacemaker Activity of Interstitial Cells of Cajal and Gastric Electrical Activity", Physiol. Res, 52, pp.275~284 (2003)
- J. Vaisanen, "New method for analyzing sensitivity distributions of electroencephalography measurements", Med. Bio. Comput, 46, pp.101~108 (2008)
- O. Vaisanen, "Effect of Source Depth on the Specificity of Bipolar EEG Measurements", Proc. 28th EMBS Conference, pp.1110~1113 (2006)
- S. Grimnes, "Bioimpedance and Bioelectricity Basics. in : Jamestown Road", pp.129~138 (2000), Academic Press
- I.Y. Kim, "Detection of Gastric Contraction in Electrogastrography : Spectrum Analysis and Vector Analysis", J. of KOSOMBE, 18(3), pp.273~283 (1997)
- R. McFee, "Electrocardiographic leads I: introduction", Circulation, 8(4), pp.554~568 (1953)
- M. Nomura, "Impairment of gastrointestinal motility by nitrate administration: evaluation based on electrogastrographic changes and autonomic nerve activity", Aliment Pharmacol Ther, 20, pp.118~124 (2004)
- H. P. Parkman, "Electro- gastrography: a document prepared by the gastric section of the american Motility Society Clinical GI Motility Testing Task Force", Neurogastroenterol Motil, 15, pp.89~102 (2003)
- Z. S. Wang, "Detection of gastric slow wave uncoupling from multi-channel electrogastr- ogram: validations and applications", Neurogastroenterol Motil, 15, pp.457~465 (2003)
- C. Peng, "Electrogastrogram extraction using independent component analysis with references", Neural comput. & Applic, 16, pp.581~587 (2007)
- H.H.L. Kwok, "Autoregressive Analysis Applied to Surface and Serosal Measurements of the Human Stomach", IEEE Trans. on Biomed. Eng, 26(7) (1979)
- Y. Matsuura, "Dynamics Analysis of Electrogastrography using Double-Wayland Algorithm", Proc. 29th Conference of IEEE EMBS, pp.1973~1976 (2007)
- M. Yoshida, "Basic Study for Measurement of Electrography", Proc. 22nd IEEE EMBS, pp.1962~1963 (2000)
- M. Inoue, "EGG measurement under various situations", Proc. 23rd IEEE EMBS, pp.3356~3358 (2001)
- S. K. Wong, "Trans- cutaneous electrogastrographic study of gastric myoelectric activity in transposed intrathoracic stomach after esophagectomy", Diseases of the Esophagus, 20, pp.69~74 (2007)
- C. H. Durney, "Basic Introduction to Bioelec- tromagnetics", pp.35~55 (2000), CRC Press