컴프턴 카메라를 위한 재배열 기반 확정론적 영상재구성법
Rebinning-Based Deterministic Image Reconstruction Methods for Compton Camera
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
While Compton imaging is recognized as a valuable 3-D technique in nuclear medicine, reconstructing an image from Compton scattered data has been of a difficult problem due to its computational complexity. The most complex and time-consuming computation in Compton camera reconstruction is to perform the conical projection and backprojection operations. To alleviate the computational burden imposed by these operations, we investigate a rebinning method which can convert conical projections into parallel projections. The use of parallel projections allows to directly apply the existing deterministic reconstruction methods, which have been useful for conventional emission tomography, to Compton camera reconstruction. To convert conical projections into parallel projections, a cone surface is sampled with a number of lines. Each line is projected onto an imaginary plane that is mostly perpendicular to the line. The projection data rebinned in each imaginary plane can then be treated as the standard parallel projection data. To validate the rebinning method, we tested with the representative deterministic algorithms,such as the filtered backprojection method and the algebraic reconstruction technique. Our experimental results indicate that the rebinning method can be useful when the direct application of existing deterministic methods is needed for Compton camera reconstruction
Abstract
While Compton imaging is recognized as a valuable 3-D technique in nuclear medicine, reconstructing an image from Compton scattered data has been of a difficult problem due to its computational complexity. The most complex and time-consuming computation in Compton camera reconstruction is to perform the conical projection and backprojection operations. To alleviate the computational burden imposed by these operations, we investigate a rebinning method which can convert conical projections into parallel projections. The use of parallel projections allows to directly apply the existing deterministic reconstruction methods, which have been useful for conventional emission tomography, to Compton camera reconstruction. To convert conical projections into parallel projections, a cone surface is sampled with a number of lines. Each line is projected onto an imaginary plane that is mostly perpendicular to the line. The projection data rebinned in each imaginary plane can then be treated as the standard parallel projection data. To validate the rebinning method, we tested with the representative deterministic algorithms,such as the filtered backprojection method and the algebraic reconstruction technique. Our experimental results indicate that the rebinning method can be useful when the direct application of existing deterministic methods is needed for Compton camera reconstruction
참고문헌 (17)
- M.Singh, "An electronically collimated gamma camera for single photon emission computed tomography: Part1 and 2", Med. Phys, 10(4), pp.421~427 (1983)
- A. Andreyev, "Reconstructed image spatial resolution of multiple coincidences compton imager", IEEE Trans. Nucl. Sci, 57, pp.151~159 (2010)
- T. Hebert, "Three-dimensional maximum- likelihood reconstructin for a electronically collimated single-photon-emission imaging system", J. Opt. Soc. Am, 7, pp.1305~1313 (1990)
- A. C. Sauve, "3D image reconstruction for Compton SPECT camera model", IEEE Trans. Nucl. Sci, 46, pp.2075~2084 (1999)
- S. M. Kim, "Fully three-dimensional image reconstruction for compton imaging using ordered subsets of conical projection data", IEEE NSS&MIC Conference Record, pp.3070~3073 (2007)
- S. -J. Lee, "Three-dimensional edge-preserving regularization for Compton camera reconstruction", IEEE NSS&MIC Conference Record, pp.4223~4228 (2008)
- 이미노, "행작용 최대우도 알고리즘을 사용한 컴프턴 산란 데이터로부터의 3차원 영상재구성", 의공학회지, 30(1), pp.56~65 (2009), 대한의용생체공학회
- A. Andreyev, "Stochastic image reconstruction method for Compton camera", IEEE NSS&MIC Conference Record, pp.2985~2988 (2009)
- R. Basko, "Application of spherical harmonics to image reconstruction for the Compton camera", Phys. Med. Biol, 43, pp.887~894 (1998)
- L.C.Parra, "Reconstruction of cone-beam projections from Compton scattered data", IEEE Trans. Nucl. Sci, 47, pp.1543~1550 (2000)
- T. Tomitani, "Image reconstruction from limited angle Compton camera data", Phys, Med. Biol, 47, pp.1009~1026 (2002)
- M. Hirasawa, "An analytical image reconstruction algorithm to compensate for scattering angle broadening in Compton cameras", Phys. Med. biol, 48, pp.1009~1026 (2003)
- B.Smith, "Reconstruction methods and completeness conditions for two Compton data models", J. Opt. Soc. Am. A, 22(3), pp.445~459 (2005)
- D. Xu, "Filtered back-projection in 4π Compton imaging with a single 3D position sensitive CdZnTe detector", IEEE Trans. Nucl. Sci, 53(5), pp.2787~2793 (2006)
- J. Li, "A rebinning technique for 3D reconstruction of Compton camera data", IEEE NSS&MIC Conference Record, pp.1877~1881 (2001)
- G. T. Herman, "Algebraic reconstruction techniques can be made computationally efficient", IEEE Trans. Med. Imaging, 12, pp.600~609 (1993)
- S. M. Kim, "Two approaches to implementing projector-backprojector pairs for 3D reconstruction from Compton scattered data", NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 571, pp.255~258 (2007), ELSEVIER SCIENCE BV
