나노웹 섬유형 전극 인터페이스와 KHU Mark2 EIT 시스템을 이용한 생체신호 동기 도전율 영상법

Gated Conductivity Imaging using KHU Mark2 EIT System with Nano-web Fabric Electrode Interface

3

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Electrical impedance tomography(EIT) can produce functional images with conductivity distributions associated with physiological events such as cardiac and respiratory cycles. EIT has been proposed as a clinical imaging tool for the detection of stroke and breast cancer, pulmonary function monitoring, cardiac imaging and other clinical applications. However EIT still suffers from technical challenges such as the electrode interface, hardware limitations,lack of animal or human trials, and interpretation of conductivity variations in reconstructed images. We improved the KHU Mark2 EIT system by introducing an EIT electrode interface consisting of nano-web fabric electrodes and by adding a synchronized biosignal measurement system for gated conductivity imaging. ECG and respiration signals are collected to analyze the relationship between the changes in conductivity images and cardiac activity or respiration. The biosignal measurement system provides a trigger to the EIT system to commence imaging and the EIT system produces an output trigger. This EIT acquisition time trigger signal will also allow us to operate the EIT system synchronously with other clinical devices. This type of biosignal gated conductivity imaging enables capture of fast cardiac events and may also improve images and the signal-to-noise ratio (SNR) by using signal averaging methods at the same point in cardiac or respiration cycles. As an example we monitored the beat by beat cardiac-related change of conductivity in the EIT images obtained at a common state over multiple respiration cycles. We showed that the gated conductivity imaging method reveals cardiac perfusion changes in the heart region of the EIT images on a canine animal model. These changes appear to have the expected timing relationship to the ECG and ventilator settings that were used to control respiration. As EIT is radiation free and displays high timing resolution its ability to reveal perfusion changes may be of use in intensive care units for continuous monitoring of cardiopulmonary function.

Abstract

Electrical impedance tomography(EIT) can produce functional images with conductivity distributions associated with physiological events such as cardiac and respiratory cycles. EIT has been proposed as a clinical imaging tool for the detection of stroke and breast cancer, pulmonary function monitoring, cardiac imaging and other clinical applications. However EIT still suffers from technical challenges such as the electrode interface, hardware limitations,lack of animal or human trials, and interpretation of conductivity variations in reconstructed images. We improved the KHU Mark2 EIT system by introducing an EIT electrode interface consisting of nano-web fabric electrodes and by adding a synchronized biosignal measurement system for gated conductivity imaging. ECG and respiration signals are collected to analyze the relationship between the changes in conductivity images and cardiac activity or respiration. The biosignal measurement system provides a trigger to the EIT system to commence imaging and the EIT system produces an output trigger. This EIT acquisition time trigger signal will also allow us to operate the EIT system synchronously with other clinical devices. This type of biosignal gated conductivity imaging enables capture of fast cardiac events and may also improve images and the signal-to-noise ratio (SNR) by using signal averaging methods at the same point in cardiac or respiration cycles. As an example we monitored the beat by beat cardiac-related change of conductivity in the EIT images obtained at a common state over multiple respiration cycles. We showed that the gated conductivity imaging method reveals cardiac perfusion changes in the heart region of the EIT images on a canine animal model. These changes appear to have the expected timing relationship to the ECG and ventilator settings that were used to control respiration. As EIT is radiation free and displays high timing resolution its ability to reveal perfusion changes may be of use in intensive care units for continuous monitoring of cardiopulmonary function.

참고문헌 (23)

  1. L. A. Geddes, "The specific resistance of biological material: a compendium of data for the biomedical engineer and physiologist", Medical Engineering & Physics, 5(3), pp.271~293 (1967)
  2. S. Gabriel, "The dielectric properties of biological tissues: II. measurements in the frequency range 10 Hz to 20 GHz", Phys. Med. Biol, 41(11), pp.2251~2269 (1996)
  3. C. Gabriel, "The dielectric properties of biological tissues: I. literature survey", Phys. Med. Biol, 41(11), pp.2231~2249 (1996)
  4. S. Grimnes, "Bioimpedance and Bioelectricity Basics, 2nd Ed" (2008), Academic Press
  5. D. S. Holder, "Electrical Impedance Tomography: Methods, History and Applications" (2005), Univ. Press
  6. J. G. Webster, "Electrical Impedance Tomography" (1990), Univ. Press
  7. I. Frerichs, "Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities", Physiol. Meas, 21(2), pp.1~21 (2000)
  8. Y. Zou, "A review of electrical impedance techniques for breast cancer detection", Medical Engineering & Physics, 25(2), pp.79~90 (2003)
  9. J. Sola, "Non-invasive monitoring of central blood pressure by electricalimpedance tomography: first experimental evidence", Med. Eng. Comput, 49(4), pp.409~415 (2011)
  10. A. McEwan, "A review of errors in multi-frequency EIT instrumentation", Physiol. Meas, 28(7), pp.197~215 (2007)
  11. B. H. Brown, "Electrical impedance tomography (EIT): a review", J of Med. Eng. & Tech, 27(3), pp.97~108 (2003)
  12. J. M. Deibele, "Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography", Physiol. Meas, 29(6), pp.1~14 (2008)
  13. G. Hahn, "Different approaches for quantifying ventilation distribution and lung tissue properties by functional EIT", Physiol. Meas, 31(8), pp.73~84 (2010)
  14. P. Yan, "Estimation of Locating the Multi-Conductivity Distribution in Electrical Impedance Tomography Using ICA", in Proc. Diagnostics and Treatment II, 5630, pp.523~530 (2005)
  15. J. H. Li, "Fast EIT data acquisition system with active electrodes and its application to cardiac imaging", Physiol. Meas, 17(4), pp.25~32 (1996)
  16. R. J. Sadleir, "Inflatable belt for the application of electrode arrays", Rev. Sci. Instrum, 71(2), pp.530~535 (2000)
  17. Tong In Oh, "Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture", 의공학회지, 26(4), pp.215~221 (2005), 대한의용생체공학회
  18. 오동인, "다주파수 임피던스 단층촬영 시스템", 의공학회지, 28(1), pp.66~74 (2007), 대한의용생체공학회
  19. T. I. Oh, "A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2", Physiol. Meas, 32(7), pp.835~849 (2011)
  20. R. D. Cook, "ACT3: a high-speed, high-precision electrical impedance tomography", IEEE Trans. Biomed. Eng, 41(8), pp.713~722 (1994)
  21. A. V. Noordegraaaf, "Determination of stroke volume by means of electrical impedance tomography", Physiol. Meas, 21(2), pp.285~293 (2000)
  22. P. J. Xu, "Textile-structured electrodes for electrocardiogram", Textile Progress, 40(4), pp.183~213 (2008)
  23. S. Franco, "Design with Operational Amplifiers and Analog Integrated Circuits 3rd. ed" (2002), McGraw-Hill Press

관련 논문AI추천

이 간행물의 다른 논문 (6건)