본문 바로가기
KERD
논문KCI 등재

광용적맥파 신호를 활용한 비침습적 혈압 측정 기술의 현황

A Brief Review of Non-Invasive Blood Pressure Estimation Techniques Using Photoplethysmographic Signals

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

In this study, we conducted a brief review of 254 studies on blood pressure estimation using photopleth- ysmography (PPG). The analysis revealed a growing trend in research on blood pressure prediction using PPG. Ini- tially, simple methods like regression analysis were commonly used, but recent studies predominantly employ deep learning techniques. Additionally, many studies use other signals in conjunction with PPG for blood pressure esti- mation. There were numerous cases where PPG signals were measured using wearable devices or custom hardware, and a significant number of studies utilized publicly available datasets. The features used in blood pressure prediction were classified into six categories for analysis, and it was found that the combination of two feature categories was the most common approach. Overall, Temporal features were the most frequently used. Based on these findings, it is suggested that future research on blood pressure estimation using PPG should carefully consider factors such as signal characteristics, preprocessing, and feature extraction when developing models.

Abstract

In this study, we conducted a brief review of 254 studies on blood pressure estimation using photopleth- ysmography (PPG). The analysis revealed a growing trend in research on blood pressure prediction using PPG. Ini- tially, simple methods like regression analysis were commonly used, but recent studies predominantly employ deep learning techniques. Additionally, many studies use other signals in conjunction with PPG for blood pressure esti- mation. There were numerous cases where PPG signals were measured using wearable devices or custom hardware, and a significant number of studies utilized publicly available datasets. The features used in blood pressure prediction were classified into six categories for analysis, and it was found that the combination of two feature categories was the most common approach. Overall, Temporal features were the most frequently used. Based on these findings, it is suggested that future research on blood pressure estimation using PPG should carefully consider factors such as signal characteristics, preprocessing, and feature extraction when developing models.

참고문헌 (33)

  1. Cho JG, "Status and Prospect of Healthcare Sensing Technology for Wearable Devices", The Korean Institute of Electrical Engineers, 11, pp.23~27 (2016)
  2. Kil HK, "Invasive and Non-invasive Blood Pressure Measurement during Anesthesia", Korean Journal of Anesthesiology, 20(1), pp.9~13 (1987)
  3. Choi BC, "Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor", Journal of Sensor Science and Technology, 13(5), pp.383~391 (2004)
  4. Kim KB, "Photoplethysmography in Wearable Devices : A Comprehensive Review of Technological Advances, Current Challenges, and Future Directions", Electronics, 12(13), pp.2923~ (2023)
  5. Suboh MZ, "Analysis on Four Derivative Waveforms of Photoplethysmogram(PPG)for Fiducial Point Detection", Frontiers in Public Health, 10, pp.920946~ (2022)
  6. Abdullah S, "A Novel Fiducial Point Extraction Algorithm to Detect C and D Points from the Acceleration Photoplethysmogram(CnD)", Electronics, 12(5), pp.1174~ (2023)
  7. Slapnicar G, "Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network", Sensors(Basel), 19(15), pp.3420~ (2019)
  8. Djawad Y, "Essential Feature Extraction of Photopleysmography Signal of Men and Women in Their 20s", Engineering Journal, 21(4), pp.259~272 (2017)
  9. Giovangrandi L, "Ballistocardiograpy - A Method Worth Revisiting", 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp.4279~4282 (2011)
  10. Zhu B, "Review of Phonocardiogram Signal Analysis : Insights from the PhysioNet", CinC Challenge 2016 Database, 2024, pp.13(16), 3222~
  11. Chowdhury MH, "Estimating Blood Pressure from the Photoplethysmogram Signal and Demographic Features Using Machine Learning Techniques", Sensors, 20(11), pp.3127~ (2020)
  12. Yang S, "Blood pressure Estimation With Complexity Features From Electrocardiogram and Photoplethysmogram Signals", Optical and Quantum Electronics, 52, pp.1~16 (2020)
  13. Liu ZD, "Cuffless Blood Pressure Measurement Using Smartwatches : A Large-Scale Validation Study", IEEE Journal of Biomedical and Health Informatics, 27(9), pp.4216~4227 (2023)
  14. Yang SM, "Estimation and Validation of Arterial Blood Pressure Using Photoplethysmogram Morphology Features in Conjunction With Pulse Arrival Time in Large Open Databases", IEEE Journal of Biomedical and Health Informatics, 25(4), pp.1018~1030 (2021)
  15. IEEE Standard Association, "IEEE standard for wearable, cuffless blood pressure measuring devices–Amendment 1(Amendment to IEEE Std 1708–2014)", IEEE Std. 1708a-2019, 1~35 (2019)
  16. Tsai PY, "Coherence between decomposed components of wrist and finger PPG signals by imputing missing features and resolving ambiguous features", Sensors, 21(13), pp.4315~ (2021)
  17. Cui M, "ACNN-BiLSTM : A Deep Learning Approach for Continuous Noninvasive Blood Pressure Measurement Using Multi-Wavelength PPG Fusion", Bioengineering, 11(4), pp.306~ (2024)

관련 논문AI추천

이 간행물의 다른 논문 (13건)