With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management pro- cess basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

Abstract

With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management pro- cess basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

참고문헌 (14)

  1. "COUNCIL DIRECTIVE 93", 42, pp.1993, 1~43
  2. "MFDS. Medical device manufacturing", import and quality Management standards, 2005
  3. "REGULATION (EU) 2017", 745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL, 2017, pp.1~175
  4. MedTech Europe Survey Report Analysing the availability of Medical Devices in 2022 in connection to the Medical Device Regulation (MDR) implementation, , ~ (2022)
  5. MFDS, "A year of 2021 Medical Device production and import", export performance statistical data, 2022, pp.6~7
  6. A year of 2020 Medical Device Industry Analysis Report, "KHIDI", 59~62 (2021)
  7. MFDS Risk management plan & report guidance, , ~ (2008)
  8. MOLEG, "Medical Device Act Enforcement Rules", ~ (2022)
  9. "MDCG 2021-24, Guidance on classification of medical devices", 5~ (2021)
  10. "ISO 14971:2019 Medical devices, Application of risk management to medical devices", 1~46 (2019)
  11. "ISO", TR 24971:2020 Medical devices, Guidance on the application of ISO 14971, 2019, pp.22~49
  12. Karolina N, "Methylparaben-induced regulation of estrogenic signaling in human neutrophils", Mole. Cell. End, 538, pp.111470~ (2021)
  13. MDCG 2022-21, Guidance on periodic safety update report (PSUR) according to regulation (EU) 2017, "745 (MDR)", 2022, pp.21~

이 간행물의 다른 논문 (11건)