Quantitative molecular genetic tests are increasingly used for the detection and quantification of target molecules or genetic alterations. When introducing a new assay into clinical laboratories, it is necessary to verify the manufacturers’ claimed performance characteristics within individual laboratories. Appropriate assay verification procedures are essential to ensure the quality of test results in clinical laboratories. This study aimed to provide recommendations for the verification of quantitative molecular genetic testing focused on the hemato-oncology field in clinical genetic laboratories. Based on a literature review, we provide recommendations for the performance verification of quantitative molecular hemato-oncology tests. The performance characteristic elements that comprise the verification procedures are presented and exemplified. These recommendations can assist individual clinical laboratories in verifying quantitative molecular diagnostic assays

Abstract

Quantitative molecular genetic tests are increasingly used for the detection and quantification of target molecules or genetic alterations. When introducing a new assay into clinical laboratories, it is necessary to verify the manufacturers’ claimed performance characteristics within individual laboratories. Appropriate assay verification procedures are essential to ensure the quality of test results in clinical laboratories. This study aimed to provide recommendations for the verification of quantitative molecular genetic testing focused on the hemato-oncology field in clinical genetic laboratories. Based on a literature review, we provide recommendations for the performance verification of quantitative molecular hemato-oncology tests. The performance characteristic elements that comprise the verification procedures are presented and exemplified. These recommendations can assist individual clinical laboratories in verifying quantitative molecular diagnostic assays

참고문헌 (23)

  1. Heuser M, "2021 Update on MRD in acute myeloid leukemia : a consensus document from the European LeukemiaNet MRD Working Party", Blood, 138, pp.2753~2767 (2021)
  2. Mazaika E, "Digital droplet PCR : CNV analysis and other applications", Curr Protoc Hum Genet, 82, pp.7.24.1~7.24.13 (2014)
  3. Halling KC, "Test veriflcation and validation for molecular diagnostic assays", Arch Pathol Lab Med, 136, pp.11~13 (2012)
  4. Evaluation of detection capability for clinical laboratory measurement procedures; Approved guideline—Second edition, "Clinical and Laboratory Standards Institute", Clinical and Laboratory Standards Institute, ~, pp.CLSI document EP17-A2 (2012)
  5. "Molecular Diagnostic Assay Validation : Update to the 2009 AMP Molecular Diagnostic Assay Validation White Paper" (2014)[URL]
  6. Molecular methods for clinical genetics and oncology testing; Approved guideline—Third edition, "Clinical and Laboratory Standards Institute", Clinical and Laboratory Standards Institute, ~, pp.CLSI document MM01-A3 (2012)
  7. Quality management for molecular genetic testing; Approved guideline, "Clinical and Laboratory Standards Institute", Clinical and Laboratory Standards Institute, ~, pp.CLSI document MM20-A (2012)
  8. Evaluation of linearity of quantitative measurement procedures, "Clinical and Laboratory Standards Institute", Clinical and Laboratory Standards Institute, ~, pp.CLSI guideline EP06-Ed2 (2020)
  9. User veriflcation of precision and estimation of bias; Approved guideline—Third edition, "Clinical and Laboratory Standards Institute", Clinical and Laboratory Standards Institute, ~, pp.CLSI document EP15-A3 (2014)
  10. Deflning, establishing, and verifying reference intervals in the clinical laboratory; Approved guideline—3rd edition, "Clinical and Laboratory Standards Institute", Clinical and Laboratory Standards Institute, ~, pp.CLSI guideline EP28-A3c (2010)
  11. "Standard: Establishment and veriflcation of performance speciflcations. 42 CFR § 493.1253, Oct. 1, 2015"[URL]
  12. College of American Pathologists, "Molecular pathology checklist" (2021), College of American Pathologists
  13. Mattocks CJ, "A standardized framework for the validation and veriflcation of clinical molecular genetic tests", Eur J Hum Genet, 18, pp.1276~1288 (2010)
  14. Jennings L, "Recommended principles and practices for validating clinical molecular pathology tests", Arch Pathol Lab Med, 133, pp.743~755 (2009)
  15. Hee-Jung Chung, "Performance Evaluation of the QXDx BCR-ABL %IS Droplet Digital PCR Assay", Annals of Laboratory Medicine, 40(1), pp.72~75 (2020), 대한진단검사의학회[DOI]
  16. Broeders S, "Guidelines for validation of qualitative real-time PCR methods", Trends Food Sci Technol, 37, pp.115~126 (2014)
  17. Jennings LJ, "Design and analytic validation of BCR-ABL1 quantitative reverse transcription polymerase chain reaction assay for monitoring minimal residual disease", Arch Pathol Lab Med, 136, pp.33~40 (2012)
  18. Armbruster DA, "Limit of blank, limit of detection and limit of quantitation", Clin Biochem Rev, 29(Suppl 1), pp.S49~S52 (2008)
  19. Shrivastava A, "Methods for the determination of limit of detection and limit of quantitation of the analytical methods", Chron Young Sci, 2, pp.21~25 (2011)
  20. "Rare Mutation Detection Best Practices Guidelines"[URL]
  21. Yuan D, "Droplet digital PCR for quantiflcation of PML-RARα in acute promyelocytic leukemia : a comprehensive comparison with real-time PCR", Anal Bioanal Chem, 411, pp.895~903 (2019)
  22. Wolstencroft EC, "Development of a quantitative real-time polymerase chain reaction assay for the detection of the JAK2 V617F mutation", J Mol Diagn, 9, pp.42~46 (2007)
  23. Schnittger S, "Development and validation of a real-time quantiflcation assay to detect and monitor BRAFV600E mutations in hairy cell leukemia", Blood, 119, pp.3151~3154 (2012)

관련 논문AI추천

Performance Evaluation of the QXDx BCR-ABL %IS Droplet Digital PCR Assay허미나, Hanah Kim, Hee-Jung Chung, Hee-Won Moon, Hwan-Sub Lim, Keumrock Hwang, Sumi Yoon, Yeo-Min Yun대한진단검사의학회 · Annals of Laboratory Medicine2020 · 제40권 제1호Korean Society for Genetic Diagnostics Guidelines for Validation of Next-Generation Sequencing-Based Somatic Variant Detection in Hematologic Malignancies김선희, 김종원, 김혜진, 김희진, 윤재원, 이승태대한진단검사의학회 · Annals of Laboratory Medicine2019 · 제39권 제6호Essential Elements for Establishing Clinical Next-generation Sequencing Testing민원기, 박경진, 이우창, 전사일대한진단검사의학회 · Laboratory Medicine Online2019 · 제9권 제2호Development and Characterization of Reference Materials for Genetic Testing: Focus on Public Partnerships한진영, Justin M. Zook, Lisa V. Kalman, Marc L. Salit, Mickey Williams, Vivekananda Datta대한진단검사의학회 · Annals of Laboratory Medicine2016 · 제36권 제6호BCR::ABL1 정량 검사의 국내 현황 조사(2022)김미영, 김인숙, 김현영, 신새암, 이자영대한진단검사의학회 · Laboratory Medicine Online2023 · 제13권 제4호Good Laboratory Standards for Clinical Next-Generation Sequencing Cancer Panel Tests최진, 고영혜, 김나영, 김지훈, 박웅양, 성창옥, 심효섭, 원재경, 장세진, 천성민, 최윤라대한병리학회 · Journal of Pathology and Translational Medicine2017 · 제51권 제3호

이 간행물의 다른 논문 (11건)