In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5measurement instruments can be obtained through the inter-comparison results based on filterbased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Abstract

In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5measurement instruments can be obtained through the inter-comparison results based on filterbased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

참고문헌 (11)

  1. 김상렬, "부산시의 PM-2.5 특성과 지역 기준 달성도 평가", 1999년 대기환경학회 추계 학술대회 논문집, pp.28~29 (1999)
  2. 김광래, "서울지역의 TSP, PM10, PM2.5의 농도 변화에 관한 연구", 2003년 대기환경학회 추계 학술대회 논문집, pp.343~344 (2003)
  3. 정창훈, "비교 측정을 통한 PM-10 질량농도의 오차 분석", 한국대기환경학회지, 23(6), pp.689~698 (2007), 한국대기환경학회
  4. 한진석, "우리나라 지역별 PM-2.5 에어로졸 특성", 2004년 대기환경학회 추계 학술대회 논문집, pp.331~332 (2004)
  5. Chang, C. T., "Differences in PM-10 concentrations measured by beta gauge monitor and high-vol sampler", Atmos. Env., 35, pp.5741~5748 (2001)
  6. Chang, C. T., "A model for the relative humidity effect on the readings of the PM-10 beta-gauge monitor", Journal of Aerosol Science, 34(12), pp.1685~1697 (2003)
  7. Motallebi, N., "Particulate Matter in California: Part 1-Intercomparison of Several PM2.5, PM10-2.5, and PM10 Monitoring Networks", J. Air & Waste Manage. Assoc., 53(12), pp.1509~1516 (2003)
  8. Comparison of the ARB continuous PM-2.5 monitoring network to the PM-2.5 federal reference method network, California Air Resources Boards Report, "Quok, M.", 1~21 (2006)
  9. Schwab, J. J., "New York State Urban and Rural Measurements of Continuous PM2.5 Mass by FDMS, TEOM, and BAM", J. Air & Waste Manage. Assoc., 56(4), pp.372~383 (2006)
  10. Tsai, C. J., "Comparison of two ambient beta gauge PM-10 samplers", J. Air & Waste Manage. Assoc., 46(2), pp.142~147 (1996)
  11. Wu, J, "Exposure assessment of particulate matter air pollution before, during, and after the 2003 Southern California wildfires", Atmospheric Environment, 40(18), pp.3333~3348 (2006)