Background: The demographics of the stroke population consist mainly of elderly patients. Transcranial Doppler is aneffective method for intracranial flow detection, but can be limited due to the poor temporal window (PTW), which isfrequent in the elderly. Therefore, we investigated whether the low frequency 1.6-MHz probe can be useful to improveflow detection for PTW. Methods: All 201 participants had a history of transient ischemic attack or minor ischemic stroke. Firstly, we analyzed thesuccess rate of recording intracranial blood flow via temporal window by using 2.0-MHz (high frequency, HF) and1.6-MHz (low frequency, LF) probes for a maximum of 10 minutes. Secondly, mean flow velocity (MFV) and pulsatileindex (PI) of insonated spectrum of 25 patients with good temporal window were compared between the two probes. Results: Seventy-eight patients were female and the mean age was 64.1±12.4 years. Among 402 windows, 125 (31.1%)were undetected when using the 2.0-MHz probe. Fifty-five patients were detected for the spectrum by the 1.6-MHzprobe. However, 70 (17.4%) still remained as PTW. Between the two probes, there were no significant differences ofvariables from the middle cerebral arteries: MFVs (HF 61.0±14.1 vs. LF 61.3±14.8 cm/sec, p=0.403 in the right; HF59.6±13.4 vs. LF 59.3±13.3 cm/sec, p=0.232 in the left) and PIs (HF 0.82±0.17 vs. LF 0.82±0.18, p=0.929 in the right; HF0.82±0.20 vs. LF 0.83±0.17, p=0.605 in the left). Conclusions: Conventional 2.0-MHz probe had relatively high proportion of PTW but 1.6- MHz probe was feasible toimprove flow detection for PTW.
Abstract
Background: The demographics of the stroke population consist mainly of elderly patients. Transcranial Doppler is aneffective method for intracranial flow detection, but can be limited due to the poor temporal window (PTW), which isfrequent in the elderly. Therefore, we investigated whether the low frequency 1.6-MHz probe can be useful to improveflow detection for PTW. Methods: All 201 participants had a history of transient ischemic attack or minor ischemic stroke. Firstly, we analyzed thesuccess rate of recording intracranial blood flow via temporal window by using 2.0-MHz (high frequency, HF) and1.6-MHz (low frequency, LF) probes for a maximum of 10 minutes. Secondly, mean flow velocity (MFV) and pulsatileindex (PI) of insonated spectrum of 25 patients with good temporal window were compared between the two probes. Results: Seventy-eight patients were female and the mean age was 64.1±12.4 years. Among 402 windows, 125 (31.1%)were undetected when using the 2.0-MHz probe. Fifty-five patients were detected for the spectrum by the 1.6-MHzprobe. However, 70 (17.4%) still remained as PTW. Between the two probes, there were no significant differences ofvariables from the middle cerebral arteries: MFVs (HF 61.0±14.1 vs. LF 61.3±14.8 cm/sec, p=0.403 in the right; HF59.6±13.4 vs. LF 59.3±13.3 cm/sec, p=0.232 in the left) and PIs (HF 0.82±0.17 vs. LF 0.82±0.18, p=0.929 in the right; HF0.82±0.20 vs. LF 0.83±0.17, p=0.605 in the left). Conclusions: Conventional 2.0-MHz probe had relatively high proportion of PTW but 1.6- MHz probe was feasible toimprove flow detection for PTW.
참고문헌 (17)
- Aaslid R, "Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries", J Neurosurg, 57, pp.769~774 (1982)
- Culjat MO, "A review of tissue substitutes for ultrasound imaging", Ultrasound Med Biol, 36, pp.861~873 (2010)
- Georgiadis D, "Diagnostic yield of a 1-MHz transducer in evaluation of the basal cerebral arteries", J Neuroimaging, 9, pp.15~18 (1999)
- Halsey JH, "Effect of emitted power on waveform intensity in transcranial Doppler", Stroke, 21, pp.1573~1578 (1990)
- Itoh T, "Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography", Stroke, 24, pp.1192~1195 (1993)
- Klotzsch C, "A new 1-MHz probe for transcranial Doppler sonography in patients with inadequate temporal bone windows", Ultrasound Med Biol, 24, pp.101~103 (1998)
- Kwon JH, "The thickness and texture of temporal bone in brain CT predict acoustic window failure of transcranial Doppler", J Neuroimaging, 16, pp.347~352 (2006)
- Alexandrov AV, "Ultrasound enhancement of fibrinolysis", Stroke, 40(3 Suppl), pp.S107~S110 (2009)
- 양현덕, "M-mode TCD를 이용한 한 중대뇌동맥의 양측 측두창을 통한 동시 탐지", 대한신경과학회지, 23(2), pp.172~175 (2005), 대한신경과학회
- Cullinane M, "Evaluation of a 1 MHz transducer for transcranial Doppler ultrasound including embolic signal detection", Ultrasound Med Biol, 27, pp.795~800 (2001)
- Alexandrov AV, "Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke", N Engl J Med, 351, pp.2170~2178 (2004)
- Daffertshofer M, "Transcranial low-frequency ultrasound-mediated thrombolysis in brain ischemia: increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator: results of a phase II clinical trial", Stroke, 36, pp.1441~1446 (2005)
- Rubiera M, "Do bubble characteristics affect recanalization in stroke patients treated with microbubble-enhanced sonothrombolysis?", Ultrasound Med Biol, 34, pp.1573~1577 (2008)
- Alexander Ng, "Resolution in ultrasound imaging", Contin Educ Anaesth Crit Care Pain, 11, pp.186~192 (2011)
- Lee SI, "Physics and Artifacts", Neurosonology, 3(1 suppl), pp.1~16 (2011)
- Schregel W, "Value of transcranial Doppler sonography", Infusionsther Transfusionsmed, 20, pp.267~271 (1993)
- Alexandrov AV, "Insonation method and diagnostic flow signatures for transcranial power motion (M-mode)Doppler", J Neuroimaging, 12, pp.236~244 (2002)