Treatment of Melasma and Post-Inflammatory Hyperpigmentation by a Picosecond 755-nm Alexandrite Laser in Asian Patients
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The picosecond lasers have shown to effectively treat tattoo pigments that are intractable to previous multiple Q-switched (QS) laser treatments. Therefore we hypothesized that a picosecond laser would show better efficacy with minimal adverse events in the treatment of melasma and post-inflammatory hyperpigmentation (PIH) that are difficult to treat with conventional QS lasers. Two patients with melasma and one patient with PIH were treated with a Picosecond 755-nm Alexandrite Laser (Cyanosure, USA). All patients were Korean with skin type IV and no longer responding to QS laser treatments. Laser treatment was well tolerated in all the patients. Adverse events such as PIH were not reported during 8 weeks of follow up period. After the multiple treatment sessions, one patient reported fair improvement and two patients reported good improvement. Consistent with the clinical results, ex vivo skin model irradiated with a Picosecond 755-nm Alexandrite Laser also showed decreased epidermal keratinocyte necrosis compared with the 532-nm QS Neodymium-Doped Yttrium Aluminium Garnet Laser (Lutronic, Korea) yet decreased melanin content. In conclusion, the Picosecond 755-nm Alexandrite Laser may be useful for effective treatment of intractable melasma and PIH with fewer adverse events in dark Asian skin.
Abstract
The picosecond lasers have shown to effectively treat tattoo pigments that are intractable to previous multiple Q-switched (QS) laser treatments. Therefore we hypothesized that a picosecond laser would show better efficacy with minimal adverse events in the treatment of melasma and post-inflammatory hyperpigmentation (PIH) that are difficult to treat with conventional QS lasers. Two patients with melasma and one patient with PIH were treated with a Picosecond 755-nm Alexandrite Laser (Cyanosure, USA). All patients were Korean with skin type IV and no longer responding to QS laser treatments. Laser treatment was well tolerated in all the patients. Adverse events such as PIH were not reported during 8 weeks of follow up period. After the multiple treatment sessions, one patient reported fair improvement and two patients reported good improvement. Consistent with the clinical results, ex vivo skin model irradiated with a Picosecond 755-nm Alexandrite Laser also showed decreased epidermal keratinocyte necrosis compared with the 532-nm QS Neodymium-Doped Yttrium Aluminium Garnet Laser (Lutronic, Korea) yet decreased melanin content. In conclusion, the Picosecond 755-nm Alexandrite Laser may be useful for effective treatment of intractable melasma and PIH with fewer adverse events in dark Asian skin.
참고문헌 (5)
- Kim BW, "Clinical efficacy of the dual-pulsed Q-switched neodymium:yttrium-aluminum-garnet laser: comparison with conservative mode", J Cosmet Laser Ther, 15, pp.340~341 (2013)
- Ross V, "Comparison of responses of tattoos to picosecond and nanosecond Q-switched neodymium: YAG lasers", Arch Dermatol, 134, pp.167~171 (1998)
- Saedi N, "Treatment of tattoos with a picosecond alexandrite laser: a prospective trial", Arch Dermatol, 148, pp.1360~1363 (2012)
- Chesnut C, "Treatment of nevus of ota with a picosecond 755-nm alexandrite laser", Dermatol Surg, 41, pp.508~510 (2015)
- Kim JE, "Histopathological study of the treatment of melasma lesions using a low-fluence Q-switched 1064-nm neodymium:yttrium-aluminium-garnet laser", Clin Exp Dermatol, 38, pp.167~171 (2013)
