M-mode TCD를 이용한 한 중대뇌동맥의 양측 측두창을 통한 동시 탐지
Simultaneous Insonation of One MCA through Bilateral Temporal Bone Windows Using M-mode TCD
2
조회
0
다운로드
1
인용
0
참고문헌
초록
Abstract
Background: Transcranial Doppler ultrasonography (TCD) is limited by insufficient ultrasound penetration through the temporal bone. Recent studies have revealed poor temporal bone windows in 5~30% of patients. In about 38% of the patients with poor temporal bone windows, a temporal window was unilaterally absent. The aim of the present study was to compare the mean flow velocities (MFV) of the middle cerebral arteries (MCA) obtained through the ipsilateral temporal bone window with those obtained through the contralateral one using M-mode TCD. Methods: Eighteen patients (mean age, 28 y; age range, 21~40 y) who had adequate bilateral temporal bone windows were enrolled and 36 MCAs were investigated. The investigators tried to detect the MCA through the ipsilateral and contralateral temporal windows with two 2-MHz probes simultaneously (ipsilateral insonation and contralateral one, respectively). Results: The MCA MFV measured by ipsilateral insonation was 72.58±9.78 cm/sec and that demonstrated by contralateral insonation was 70.94±9.79 cm/sec. Even though the differences between MFVs by either side insonation was 2.25~3.94% (0~13.11%) and had significant difference statistically, those were within side-to-side limit of 30% generally considered as abnormal. The mean bitemporal diameter (BTD) was 130.72±3.75 cm (126~142 cm). We obtained similar waveforms in the reverse direction to those of ipsilateral insonation at 95.33±5.19 mm of depths (72.97±4.23% of BTD) during contralateral insonation. Conclusions: The demonstration of the MCA through the contralateral insonation provides an opportunity to obtain significant mean flow velocities in patients with absent or insufficient temporal bone window unilaterally.
참고문헌 (16)
- "Effect of emitted power on waveform intensity in transcranial Doppler", 21, pp.1573~1578 (1990)
- "Transcranial Doppler ultrasound for the assessment of intracranial arterial flow velocity--Part 1.Examination technique and normal values", 27, pp.439~448 (1987)
- "Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography", 24, pp.1192~1195 (1993)
- "Transcranial Doppler ultrasound", 56, pp.378~388 (2000)
- "Potential and limitations of transcranial color-coded sonography in stroke patients", 26, pp.2061~2066 (1995)
- "A new 1-MHz probe for transcranial Doppler sonography in patients with inadequate temporal bone windows", 24, pp.101~103 (1998)
- "Success Rate of Transcranial Doppler Study", 1, pp.189~191 (1999)
- "3-dimensional echo- enhanced transcranial Doppler ultrasound diagnosis", 38, pp.394~398 (1998)
- "Diagnostic benefit of echocontrast enhancement for the insufficient transtemporal bone window", 9, pp.102~107 (1999)
- "Insufficient and absent acoustic temporal bone window:potential and limitations of transcranial contrast-enhanced color-coded sonography and contrast-enhanced power-based sonography", 23, pp.857~862 (1997)
- "Echo contrast-enhanced three-dimensional power Doppler of intracranial arteries", 24, pp.953~962 (1998)
- "The technique and normal values of transcranial Doppler ultrasonography J Korean Society for Clinical Neurophysiology 1999", pp.39~46
- "Color Doppler imaging of basal cerebral arteries:normal reference values and clinical applications", 46, pp.877~884 (1995)
- "Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults", 23, pp.1280~1286 (1992)
- "Comparative study of transcranial color duplex sonography and transcranial Doppler sonography in adults", 78, pp.776~784 (1993)
- "Angle correction in transcranial Doppler sonography", 4, pp.29~33 (1994)
