Study on Automatic External Defibrillators deployed at General Supermarkets
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: This study was to propose effective deployment of automatic external defibrillators (AEDs) installed at general supermarkets. Research design, data, and methodology : We conducted interview and data surveys on 72 large distributors in Seoul and Gyeonggi province in South Korea. The content of this survey was consisted of general status on the general supermarkets, AED deployment and management regarding public access defibrillation (PAD). G*Power (v 3.1.9.4; Universität Kiel, Kiel, Germany) was also used to analyze statistical power. Radius and actual distance, radius and retrieval time were compared by t-test at ⍺ =.05. respectively. Results : Difference between the radius (102.7 meters) and the actual distance (187.8 meters) was 85.1m, it had statistically significant difference (p<.001). The actual distance was longer compared to the radius distance. Difference between the radius (114.1 seconds) and the retrieval time (208.7 seconds) was 94.6s, it had statistically significant difference (p<.001). The retrieval time took longer compared to the radius time as well. Conclusions : The finding shows that only 45.9% of the general supermarkets are satisfied with the actual AED coverage within 3 minutes. This needs to enhance AED deployment to reduce defibrillation time and AED management to boost application in South Korea.
Abstract
Purpose: This study was to propose effective deployment of automatic external defibrillators (AEDs) installed at general supermarkets. Research design, data, and methodology : We conducted interview and data surveys on 72 large distributors in Seoul and Gyeonggi province in South Korea. The content of this survey was consisted of general status on the general supermarkets, AED deployment and management regarding public access defibrillation (PAD). G*Power (v 3.1.9.4; Universität Kiel, Kiel, Germany) was also used to analyze statistical power. Radius and actual distance, radius and retrieval time were compared by t-test at ⍺ =.05. respectively. Results : Difference between the radius (102.7 meters) and the actual distance (187.8 meters) was 85.1m, it had statistically significant difference (p<.001). The actual distance was longer compared to the radius distance. Difference between the radius (114.1 seconds) and the retrieval time (208.7 seconds) was 94.6s, it had statistically significant difference (p<.001). The retrieval time took longer compared to the radius time as well. Conclusions : The finding shows that only 45.9% of the general supermarkets are satisfied with the actual AED coverage within 3 minutes. This needs to enhance AED deployment to reduce defibrillation time and AED management to boost application in South Korea.
참고문헌 (41)
- Ahn, K. O., "Epidemiology and outcomes from non-traumatic out-of hospital cardiac arrest in Korea : A nationwide observational study", Resuscitation, 81(8), pp.974~981 (2010)
- Aufderheide, T., "Community lay rescuer automated external defibrillation programs : key state legislative components and implementation strategies : a summary of a decade of experience for healthcare providers, policymakers, legislators, employers, and community leaders from the American Heart Association Emergency Cardiovascular Care Committee, Council on Clinical Cardiology, and Office of State Advocacy", Circulation, 113, pp.1260~1270 (2006)
- Bardy, G. H., "Home use of automated external defibrillators for sudden cardiac arrest", N Engl J Med, 358, pp.1793~1804 (2008)
- Chan, P. S., "Hospital variation in time to defibrillation after in-hospital cardiac arrest", Arch Intern Med, 169(14), pp.1265~1273 (2009)
- Cohen, J., "Statistical power analysis for the behavioral sciences" (1988), Lawrence Erlbaum Associates
- Eckstein, M., "The Los Angeles public access defibrillator(PAD)program : Ten years after", Resuscitation, 83, pp.1411~1412 (2012)
- "E-Mart" (2019)[URL]
- Fleischhackl, R., "Results from Austria’s nationwide public access defibrillation(ANPAD)programme collected over 2years", Resuscitation, 77, pp.195~200 (2008)
- EMS quality management analysis report in 2018, "Gyeonggi Disaster and Safety Headquarters", ~ (2018)
- Hallstrom, A. P., "Public-access defibrillation and survival after out-of-hospital cardiac arrest", N Engl J Med, 351, pp.637~646 (2004)
- Hansen, C. M., "Differences between out-of-hospital cardiac arrest in high and low-incidence areas and implications for public access defibrillation", Resuscitation, Poster Presentations, 84S, pp.S66~ (2013)
- "Homeplus" (2019)[URL]
- 김종락, "종합슈퍼마켓(GSM)에서 서비스품질, 보증 및 서비스가치의 영향요인에 관한 연구", 유통과학연구, 13(1), pp.93~103 (2015), 한국유통과학회[DOI]
- 김태성, "종합슈퍼마켓의 소비자들의 구매경향별 POP광고반응에 관한 연구", 유통과학연구, 8(1), pp.35~42 (2010), 한국유통과학회[DOI]
- 2006-2016 Sudden cardiac death survey results, "Korea Centers for Disease Control and Prevention", ~ (2017)
- Korea Ministry of Government Legislation, "The Emergency Medical Service Act (Act No. 14218)", ~ (2016)
- Korea Ministry of Government Legislation, "Distribution Industry Development Act (Act No. 14480)", ~ (2016)
- 권오철, "소매업태 용어 통일화에 대한 소고", 유통과학연구, 5(2), pp.5~16 (2007), 한국유통과학회[DOI]
- Lin, H. Y., "Survival outcome analysis of public automated external defibrillators in Taiwan", Circulation, Poster Abstract Presentations, 138, pp.A182~ (2018)
- "Lotte Mart" (2019)[URL]
- Matzke, J., "Functional assessment of community-based automated external defibrillators", Circulation, Poster Abstract Presentations, 134, pp.A14999~ (2018)
- "Ministry of the Interior and Safety" (2019)[URL]
- Moon, S., "Analysis of out-of-hospital cardiac arrest location and public access defibrillator placement in Metropolitan Phoenix, Arizona", Resuscitation, 89, pp.43~49 (2015)
- "2017 Statistics Annual Report" (2018)[URL]
- Nielsen, A. M., "Use and benefits of public access defibrillation in a nation-wide network", Resuscitation, 84, pp.430~434 (2013)
- Parry, M., "The association between diabetes status and survival following an out of-hospital cardiac arrest : A retrospective cohort study", Resuscitation, 113, pp.21~26 (2017)
- Rea, T. D., "A population-based investigation of public access defibrillation : Role of emergency medical services care", Resuscitation, 81, pp.163~167 (2010)
- Sasson, C., "Predictors of survival from out-of-hospital cardiac arrest: a systematic review and meta-analysis", Circ Cardiovasc Qual Outcomes, 3(1), pp.63~81 (2010)
- Schober, P., "Public Access Defibrillation : Time to Access the Public", Annals of Emergency Medicine, 58(3), pp.240~247 (2011)
- Shin, S. Y., "Survival rate of out-of hospital CA patients", Fire Science and Engineering, 4, pp.307~308 (2014)
- Smith, C. M., "New signs to encourage the use of Automated External Defibrillators by the lay public", Resuscitation, 114, pp.100~105 (2017)
- Sondergaard, K. B., "Out-of-hospital cardiac arrest : Probability of bystander defibrillation relative to distance to nearest automated external defibrillator", Resuscitation, 124, pp.138~144 (2018)
- "Statistics Korea" (2017)[URL]
- Uhm, T. H., "Survival to admission after out of-hospital cardiac arrest in Seoul, South Korea", Open Access Emergency Medicine, 6, pp.63~67 (2014)
- Uhm, T. H., "Factors Affecting Delivery Time of Public Access Defibrillator in Apartment Houses", Indian Journal of Public Health Research & Development, 9(9), pp.126~132 (2018)
- Uhm, T. H., "Effect of attitude education to perform cardiopulmonary resuscitation", Journal of Engineering and Applied Sciences, 12, pp.7677~7681 (2017)
- Viereck, S., "Effect of bystander CPR initiation prior to the emergency call on ROSC and 30 day survival—An evaluation of 548 emergency calls", Resuscitation, 111, pp.55~61 (2017)
- Weisfeldt, M. L., "Public access defibrillation. A statement for healthcare professionals from the American Heart Association Task Force on automatic external defibrillation", Circulation, 92, pp.2762~2763 (1995)
- Weisfeldt, M. L., "Survival after application of automatic external defibrillators before arrival of the emergency medical system : Evaluation in the resuscitation outcomes consortium population of 21million", J Am Coll Cardiol, 55(16), pp.1713~1720 (2010)
- White, M. J., "Availability of automated external defibrillators in public high schools", The Journal of Pediatrics, 172, pp.142~146 (2016)
- "Wikipedia" (2018)[URL]