New bimaxillary orthognathic surgery planning and model surgery based on the concept of six degrees of freedom
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The aim of this paper was to propose a new method of bimaxillary orthognathic surgery planning and model surgery based on the concept of 6 degrees of freedom (DOF). A 22-year-old man with Class III malocclusion was referred to our clinic with complaints of facial deformity and chewing difficulty. To correct a prognathic mandible, facial asymmetry, flat occlusal plane angle, labioversion of the maxillary central incisors, and concavity of the facial profile, bimaxillary orthognathic surgery was planned. After preoperative orthodontic treatment,surgical planning based on the concept of 6 DOF was performed on a surgical treatment objective drawing, and a Jeon’s model surgery chart (JMSC) was prepared. Model surgery was performed with Jeon’s orthognathic surgery simulator (JOSS) using the JMSC, and an interim wafer was fabricated. Le Fort I osteotomy, bilateral sagittal split ramus osteotomy, and malar augmentation were performed. The patient received lateral cephalometric and posteroanterior cephalometric analysis in postretention for 1 year. The follow-up results were determined to be satisfactory, and skeletal relapse did not occur after 1.5years of surgery. When maxillary and mandibular models are considered as rigid bodies, and their state of motion is described in a quantitative manner based on 6 DOF, sharing of exact information on locational movement in 3-dimensional space is possible. The use of JMSC and JOSS will actualize accurate communication and performance of model surgery among clinicians based on objective measurements.
Abstract
The aim of this paper was to propose a new method of bimaxillary orthognathic surgery planning and model surgery based on the concept of 6 degrees of freedom (DOF). A 22-year-old man with Class III malocclusion was referred to our clinic with complaints of facial deformity and chewing difficulty. To correct a prognathic mandible, facial asymmetry, flat occlusal plane angle, labioversion of the maxillary central incisors, and concavity of the facial profile, bimaxillary orthognathic surgery was planned. After preoperative orthodontic treatment,surgical planning based on the concept of 6 DOF was performed on a surgical treatment objective drawing, and a Jeon’s model surgery chart (JMSC) was prepared. Model surgery was performed with Jeon’s orthognathic surgery simulator (JOSS) using the JMSC, and an interim wafer was fabricated. Le Fort I osteotomy, bilateral sagittal split ramus osteotomy, and malar augmentation were performed. The patient received lateral cephalometric and posteroanterior cephalometric analysis in postretention for 1 year. The follow-up results were determined to be satisfactory, and skeletal relapse did not occur after 1.5years of surgery. When maxillary and mandibular models are considered as rigid bodies, and their state of motion is described in a quantitative manner based on 6 DOF, sharing of exact information on locational movement in 3-dimensional space is possible. The use of JMSC and JOSS will actualize accurate communication and performance of model surgery among clinicians based on objective measurements.
참고문헌 (17)
- Bell WH, "Correction of the short-face syndromevertical maxillary deficiency: a preliminary report", J Oral Surg, 35, pp.110~120 (1977)
- Bell WH, "Surgical correction of the long face syndrome", Am J Orthod, 71, pp.40~67 (1977)
- Epker BN, "Surgical-orthodontic correction of open-bite deformity", Am J Orthod, 71, pp.278~299 (1977)
- Hohl TA, "Use of an adjustable (anatomic) articulator for case prediction in segmental surgery, In Surgical correction of dentofacial deformities", pp.169~177 (1980), W.B. Saunders
- Hill SC, "Cephalometric planning and model surgery, In Surgical correction of dentofacial deformities-New concepts", pp.217~226 (1985), W.B. Saunders
- Ellis E, "Accuracy of model surgery: evaluation of an old technique and introduction of a new one", J Oral Maxillofac Surg, 48, pp.1161~1167 (1990)
- 전재호, "6축 모형수술 시뮬레이터의 정확도에 관한 연구", 대한구강악안면외과학회지, 36(1), pp.23~27 (2010), 대한구강악안면외과학회
- Hibbeler RC, "Engineering mechanics: statics & dynamics", pp.5~ (2010), Prentice-Hall
- Hull DG, "Fundamentals of airplane flight mecha nics", pp.15~ (2007), Springer
- Schwestka-Polly R, "Application of the model-positioning appliance for three-dimensional positioning of the maxilla in cast surgery", Int J Adult Orthodon Orthognath Surg, 8, pp.25~31 (1993)
- Wong BW, "Innovations in orthognathic splint construc tion", J Clin Orthod, 19, pp.750~756 (1985)
- Bell WH, "Analytic model surgery In Modern practice in orthognathic and reconstructive surgery", pp.154~205 (1992), Saunders
- Swennen GR, "Threedimensional treatment planning of orthognathic surgery in the era of virtual imaging", J Oral Maxillofac Surg, 67, pp.2080~2092 (2009)
- Swennen G, "3D virtual reality planning of orthognathic surgery", J Oral Maxillofac Surg, 67, pp.1~ (2009)
- Kaipatur N, "Accuracy of computer programs in predicting orthognathic surgery hard tissue response", J Oral Maxillofac Surg, 67, pp.1628~1639 (2009)
- Xia JJ, "New clinical protocol to evaluate craniomaxillofacial deformity and plan surgical correction", J Oral Maxillofac Surg, 67, pp.2093~2106 (2009)
- Kaipatur NR, "Accuracy of computer programs in predicting orthognathic surgery soft tissue response", J Oral Maxillofac Surg, 67, pp.751~759 (2009)
