본문 바로가기
KERD
논문KCI 등재

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient’s dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

Abstract

Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient’s dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

참고문헌 (28)

  1. Andrews LF., "The straight-wire appliance. Explained and compared", J Clin Orthod, 10, pp.174~195 (1976)
  2. Andrews LF, "The straight-wire appliance", Br J Orthod, 6, pp.125~143 (1979)
  3. Zachrisson BU, "Clinical comparison of direct versus indirect bonding with different bracket types and adhesives", Am J Orthod, 74, pp.62~78 (1978)
  4. Aguirre MJ, "Assessment of bracket placement and bond strength when comparing direct bonding to indirect bonding techniques", Am J Orthod, 82, pp.269~276 (1982)
  5. Koo BC, "Comparison of the accuracy of bracket placement between direct and indirect bonding techniques", Am J Orthod Dentofacial Orthop, 116, pp.346~351 (1999)
  6. Hodge TM, "A randomized clinical trial comparing the accuracy of direct versus indirect bracket placement", J Orthod, 31, pp.132~137 (2004)
  7. Thomas RG, "Indirect bonding : simplicity in action", J Clin Orthod, 13, pp.93~106 (1979)
  8. Kalange JT, "Indirect bonding : a comprehensive review of the advantages", World J Orthod, 5, pp.301~307 (2004)
  9. Wendl B, "Indirect bonding--a new transfer method", Eur J Orthod, 30, pp.100~107 (2008)
  10. Lee MS, "Indirect bonding of orthodontic brackets:an evaluation of transfer accuracy and reliability", Master's, pp.2014
  11. Castilla AE, "Measurement and comparison of bracket transfer accuracy of five indirect bonding techniques", Angle Orthod, 84, pp.607~614 (2014)
  12. Seo H., "Accuracy of indirect bracket bonding via virtual setup and 3D printing", Master's, pp.2016
  13. Niu Y, "Comparison of the transfer accuracy of two digital indirect bonding trays for labial bracket bonding", Angle Orthod, 91, pp.67~73 (2021)
  14. Gelin Emilie, "Innovative customized CAD", CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial, 2020, pp.50(6), 373~382[DOI]
  15. Koch PJ, "Measuring the accuracy of a computeraided design and computer-aided manufacturingbased indirect bonding tray", Am J Orthod Dentofacial Orthop, 158, pp.315~ (2020)
  16. Xue C, "Accurate bracket placement using a computer-aided design and computer-aided manufacturing-guided bonding device : an in vivo study", Am J Orthod Dentofacial Orthop, 157, pp.269~277 (2020)
  17. Kwon SI, "CENOS assignee. Bracket jig system for positioning an orthodontic bracket", Korea patent KR 10-2163625, ~ (2020)
  18. Fillion D, "Clinical advantages of the Orapix-straight wire lingual technique", Int Orthod, 8, pp.125~151 (2010)
  19. Fillion D, "Lingual straightwire treatment with the Orapix system", J Clin Orthod, 45, pp.488~497 (2011)
  20. Kim J, "Accuracy of bracket positions with a CAD", CAM indirect bonding system in posterior teeth with different cusp heights, 2018, pp.153, 298~307
  21. Little RM, "The irregularity index : a quantitative score of mandibular anterior alignment", Am J Orthod, 68, pp.554~563 (1975)
  22. Park KH, "Critical issues concerning biocreative strategy in contemporary temporary skeletal anchorage device orthodontics : a narrative review", Orthod Craniofac Res, 1, pp.39~47 (2021)
  23. Casko JS, "Objective grading system for dental casts and panoramic radiographs. American Board of Orthodontics", Am J Orthod Dentofacial Orthop, 114, pp.589~599 (1998)
  24. Wan Hassan WN, "Comparison of reconstructed rapid prototyping models produced by 3-dimensional printing and conventional stone models with different degrees of crowding", Am J Orthod Dentofacial Orthop, 151, pp.209~218 (2017)
  25. Hazeveld A, "Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques", Am J Orthod Dentofacial Orthop, 145, pp.108~115 (2014)
  26. Dietrich CA, "A validation study of reconstructed rapid prototyping models produced by two technologies", Angle Orthod, 87, pp.782~787 (2017)
  27. Gyllenhaal KA, "Accuracy of two indirect bonding transfer methods: a three-dimensional, in-vivo analysis", Master's, pp.2015
  28. Pottier T, "Accuracy evaluation of bracket repositioning by indirect bonding: hard acrylic CAD", CAM versus soft one-layer silicone trays, an in vitro study, 2020, pp.24, 3889~3897

이 간행물의 다른 논문 (7건)