본문 바로가기
KERD
논문KCI 등재

Quantitative Analysis of Tooth Mineral Content by High Resolution Microcomputed Tomography

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Teeth and bones are highly mineralized tissues containing inorganic minerals such as calcium phosphate, and a growing number of evidences show that their mineral content is associated with many diseases. Although the quantification of mineral contents by micro-computed tomography(micro- CT) has been used in diagnosis and evaluation for treating bone diseases, its application for teeth diseases has not been well established. In this study, we attempted to estimate a usefulness of a high-resolution micro-CT in analysis of human teeth. The teeth were scanned by using the Skyscan 1172 micro-CT. In order to measure tooth mineral content, beam hardening effect of the machine was corrected with a radiopaque iodinecontaining substance, iodoacetamide. Under the maximum resolution of 6.6 μm, X-ray densities in teeth and hydroxyapatite standards were obtained with Hounsfield unit (HU), and they were then converted to an absolute mineral concentration by a CT Analyzer software. In enamel layer of cusp area, the mean mineral concentration was about 2.14 mg/mm3 and there was a constant mineral concentration gradient from the enamel surface to the dentinoenamel junction. In the dentin of middle 1/3 of tooth, the mean mineral concentration was approximately 1.27 mg/mm3 and there was a constant mineral concentration gradient from the outer of root to the pulp side, ranging from 1.3 to 1.06 mg/mm3. In decay region of dentin, the mineral content was gradually decreased from the intact inner side to the decayed surface. These results suggest that high-resolution micro-CT can be as a useful tool for non-invasive measurement of mineral concentration in teeth.

Abstract

Teeth and bones are highly mineralized tissues containing inorganic minerals such as calcium phosphate, and a growing number of evidences show that their mineral content is associated with many diseases. Although the quantification of mineral contents by micro-computed tomography(micro- CT) has been used in diagnosis and evaluation for treating bone diseases, its application for teeth diseases has not been well established. In this study, we attempted to estimate a usefulness of a high-resolution micro-CT in analysis of human teeth. The teeth were scanned by using the Skyscan 1172 micro-CT. In order to measure tooth mineral content, beam hardening effect of the machine was corrected with a radiopaque iodinecontaining substance, iodoacetamide. Under the maximum resolution of 6.6 μm, X-ray densities in teeth and hydroxyapatite standards were obtained with Hounsfield unit (HU), and they were then converted to an absolute mineral concentration by a CT Analyzer software. In enamel layer of cusp area, the mean mineral concentration was about 2.14 mg/mm3 and there was a constant mineral concentration gradient from the enamel surface to the dentinoenamel junction. In the dentin of middle 1/3 of tooth, the mean mineral concentration was approximately 1.27 mg/mm3 and there was a constant mineral concentration gradient from the outer of root to the pulp side, ranging from 1.3 to 1.06 mg/mm3. In decay region of dentin, the mineral content was gradually decreased from the intact inner side to the decayed surface. These results suggest that high-resolution micro-CT can be as a useful tool for non-invasive measurement of mineral concentration in teeth.

참고문헌 (23)

  1. Postnov AA, "Quantitative analysis of bone mineral content by x-ray microtomography", Physiol Meas, 24, pp.165~178 (2003)[DOI]
  2. Graeme M Campbell, "Quantitative analysis of bone and soft tissue by micro-computed tomography: applications to ex vivo and in vivo studies", BoneKEy Reports, 3, pp.564~ (2014), Portico[DOI]
  3. Deidre L. Batchelar, "Material-specific analysis using coherent-scatter imaging", Medical Physics, 29(8), pp.1651~1660 (2002), Wiley[DOI]
  4. Aerssens J, "Variations in trabecular bone composition with anatomical site and age : potential implications for bone quality assessment", J Endocrinol, 155, pp.411~421 (1997)
  5. Schneider U, "The calibration of CT Hounsfield units for radiotherapy treatment planning", Phys Med Biol, 41, pp.111~124 (1996)[DOI]
  6. Yasuko Numata, "Micro-CT Analysis of Rabbit Cancellous Bone Around Implants", Journal of Hard Tissue Biology, 16(2), pp.91~93 (2007), Society for Hard Tissue Regenerative Biology[DOI]
  7. I. Gedalia, "Mineral Composition of Sound Dentin of Noncarious and Carious Teeth", Journal of Dental Research, 49(2), pp.456~456 (2016), SAGE Publications[DOI]
  8. Elliott JC, "Application of scanning microradiography and x-ray microtomography to studies of bones and teeth", J Xray Sci Technol, pp.102~117 (1994)[DOI]
  9. Boyde A, "Quantitive mineralization density mapping of space flight rat femoral bone at submicron resolution: BSE calibrated by CT", Bone tooth Soc Meeting, 11, pp.217~ (1990)
  10. Vera Coklica, "Density fractions in human enamel", Archives of Oral Biology, 11(12), pp.1261~1268 (1966), Elsevier BV[DOI]
  11. Bembey AK, "Elastic Modulus and Mineral Density of Dentin and Enamel in Natural Caries Lesions", Mater Res Soc, 874, pp.15~ (2011)[DOI]
  12. Davis GR, "X-ray microtomography of bones and teeth", Physiol Meas, 17, pp.121~146 (1996)[DOI]
  13. Tatiana Nogueira Rocha CLEMENTINO-LUEDEMANN, "Mineral Concentration of Natural Human Teeth by a Commercial Micro-CT", Dental Materials Journal, 25(1), pp.113~119 (2006), Japanese Society for Dental Materials and Devices[DOI]
  14. Neslihan Efeoglu, "Microcomputerised tomography evaluation of 10% carbamide peroxide applied to enamel", Journal of Dentistry, 33(7), pp.561~567 (2005), Elsevier BV[DOI]
  15. W. Jacquet, "2D image registration using focused mutual information for application in dentistry", Computers in Biology and Medicine, 39(6), pp.545~553 (2009), Elsevier BV[DOI]
  16. Kostas Verdelis, "Accelerated enamel mineralization in Dspp mutant mice", Matrix Biology, 52-54, pp.246~259 (2016), Elsevier BV[DOI]
  17. Watanabe Y, "Derivation of linear attenuation coefficients from CT numbers for low-energy photons", Phys Med Biol, 44, pp.2201~2211 (1999)[DOI]
  18. Roberson TM, "Student’s art and science of operative dentistry" (2001), Mosby
  19. Julia F. Barrett, "Artifacts in CT: Recognition and Avoidance", RadioGraphics, 24(6), pp.1679~1691 (2004), Radiological Society of North America (RSNA)[DOI]
  20. A GALPERIN, "Radiopaque iodinated polymeric nanoparticles for X-ray imaging applications", Biomaterials, 28(30), pp.4461~4468 (2007), Elsevier BV[DOI]
  21. I.A. Mjör, "The density and branching of dentinal tubules in human teeth", Archives of Oral Biology, 41(5), pp.401~412 (1996), Elsevier BV[DOI]
  22. F Mannocci, "Density of dentinal tubules affects the tensile strength of root dentin", Dental Materials, 20(3), pp.293~296 (2004), Elsevier BV[DOI]
  23. J. Palamara, "The Ultrastructure of Spindles and Tufts in Human Dental Enamel", Advances in Dental Research, 3(2), pp.249~257 (2016), SAGE Publications[DOI]

이 간행물의 다른 논문 (8건)