Feasibility of Speech Testing Using Wireless Connection in Single-Sided Cochlear Implant Users
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background and Objectives: The speech tests used to evaluate language performance in patients with bilateral deafness (BiD) and cochlear implant (CI) are problematic if applied to patients with single-sided deafness (SSD) because normal ear hearing should be excluded. Thus, we investigated the feasibility of using wireless connection to evaluate speech intelligibility of the CI ear in patients with SSD.Subjects and Methods: Patients with BiD and SSD were administered the word recognition scores (WRS) and speech intelligibility tests using an iPadbased wireless connection and conventional methods. To exclude normal side hearing in patients with SSD, masking noise and “plugged and muffed” method were used in the WRS and speech intelligibility tests, respectively.Results: In patients with BiD, the WRS and speech intelligibility tests results using wireless connection and conventional methods were similar. In patients with SSD, the WRS using masking noise in the normal hearing ear was similar to that of using wireless connection. However, 3 of 11 patients with SSD showed under-masked results if using the “plugged and muffed” method.Conclusions: Speech intelligibility testing using wireless connection is a convenient and reliable method for evaluating CI performance in patients with SSD. The “plugged and muffed” method is not recommended for evaluating CI performance in patients with SSD.
Abstract
Background and Objectives: The speech tests used to evaluate language performance in patients with bilateral deafness (BiD) and cochlear implant (CI) are problematic if applied to patients with single-sided deafness (SSD) because normal ear hearing should be excluded. Thus, we investigated the feasibility of using wireless connection to evaluate speech intelligibility of the CI ear in patients with SSD.Subjects and Methods: Patients with BiD and SSD were administered the word recognition scores (WRS) and speech intelligibility tests using an iPadbased wireless connection and conventional methods. To exclude normal side hearing in patients with SSD, masking noise and “plugged and muffed” method were used in the WRS and speech intelligibility tests, respectively.Results: In patients with BiD, the WRS and speech intelligibility tests results using wireless connection and conventional methods were similar. In patients with SSD, the WRS using masking noise in the normal hearing ear was similar to that of using wireless connection. However, 3 of 11 patients with SSD showed under-masked results if using the “plugged and muffed” method.Conclusions: Speech intelligibility testing using wireless connection is a convenient and reliable method for evaluating CI performance in patients with SSD. The “plugged and muffed” method is not recommended for evaluating CI performance in patients with SSD.
참고문헌 (15)
- Baguley DM, "The evidence base for the application of contralateral bone anchored hearing aids in acquired unilateral sensorineural hearing loss in adults", Clin Otolaryngol, 31, pp.6~14 (2006)
- Arndt S, "Comparison of pseudobinaural hearing to real binaural hearing rehabilitation after cochlear implantation in patients with unilateral deafness and tinnitus", Otol Neurotol, 32, pp.39~47 (2011)
- Arndt S, "Cochlear implant treatment of patients with single-sided deafness or asymmetric hearing loss", HNO, 65(Suppl 2), pp.98~108 (2017)
- Friedmann DR, "Single-sided deafness cochlear implantation : candidacy, evaluation, and outcomes in children and adults", Otol Neurotol, 37, pp.e154~e160 (2016)
- Schleich P, "Head shadow, squelch, and summation effects in bilateral users of the MED-EL COMBI 40", 40+ cochlear implant, 2004, pp.25, 197~204
- Zeitler DM, "Cochlear implantation for single-sided deafness in children and adolescents", Int J Pediatr Otorhinolaryngol, 118, pp.128~133 (2019)
- Deep NL, "Cochlear implantation in children with single-sided deafness", Laryngoscope, 131, pp.E271~E277 (2021)
- Buss E, "Effects of cochlear implantation on binaural hearing in adults with unilateral hearing loss", Trends Hear, 22, pp.2331216518771173~ (2018)
- Galvin JJ 3rd, "Benefits of cochlear implantation for single-sided deafness : data from the House Clinic-University of Southern California-University of California, Los Angeles Clinical Trial", Ear Hear, 40, pp.766~781 (2019)
- 변성완, "한국어의 음절빈도와 단음절 어음표의 음절분포", 대한이비인후-두경부외과학회지, 46(9), pp.737~741 (2003), 대한이비인후과학회
- Abel SM, "Sound attenuation from earmuffs and earplugs in combination : maximum benefits vs. missed information", Aviat Space Environ Med, 77, pp.899~904 (2006)
- Finke M, "Speech intelligibility and subjective benefit in single-sided deaf adults after cochlear implantation", Hear Res, 348, pp.112~119 (2017)
- Chan JC, "Evaluation of binaural functions in bilateral cochlear implant users", Int J Audiol, 47, pp.296~310 (2008)
- Gallun FJ, "Development and validation of portable automated rapid testing(PART)measures for auditory research", Proc Meet Acoust, 33, pp.050002~ (2018)
- Nishio SY, "Development and validation of an iPad-based Japanese language monosyllable speech perception test(iCI2004 monosyllable)", Acta Otolaryngol, 141, pp.267~272 (2021)
