The auditory brainstem response (ABR) is a noninvasive test that measures neural activity in response to auditory stimuli. Racial differences in head shape have provided strong evidence for specific normative data and accurate device calibration. International standards emphasize the need for standardized procedures and references. This study aimed to outline the standard procedure and related normative ABR values. Standard procedures were performed according to International Electrotechnical Commission (IEC) standards. Five studies from two countries were included to compare the normative values of the ABR. The dataset from the National Standard Reference Data Center (NSRDC) was used as reference. Normative values were described in terms of stimuli, latency, and amplitude. For click stimuli, the latency of the ABR showed different patterns across populations, such as those from Korea and the USA. Although the latencies reported by the NSRDC and for Koreans were relatively short, those reported for USA populations were longer. Using clicks, it was shown that the USA population had the largest ABR amplitude compared to those reported for the other two datasets. For Wave V latency using tone bursts, a similar pattern was identified with click stimuli. Frequency-specific trends were also observed. Although there is a lack of ABR datasets, the information and insights of the present study could be utilized as standard guidelines in research on ABR.

Abstract

The auditory brainstem response (ABR) is a noninvasive test that measures neural activity in response to auditory stimuli. Racial differences in head shape have provided strong evidence for specific normative data and accurate device calibration. International standards emphasize the need for standardized procedures and references. This study aimed to outline the standard procedure and related normative ABR values. Standard procedures were performed according to International Electrotechnical Commission (IEC) standards. Five studies from two countries were included to compare the normative values of the ABR. The dataset from the National Standard Reference Data Center (NSRDC) was used as reference. Normative values were described in terms of stimuli, latency, and amplitude. For click stimuli, the latency of the ABR showed different patterns across populations, such as those from Korea and the USA. Although the latencies reported by the NSRDC and for Koreans were relatively short, those reported for USA populations were longer. Using clicks, it was shown that the USA population had the largest ABR amplitude compared to those reported for the other two datasets. For Wave V latency using tone bursts, a similar pattern was identified with click stimuli. Frequency-specific trends were also observed. Although there is a lack of ABR datasets, the information and insights of the present study could be utilized as standard guidelines in research on ABR.

참고문헌 (29)

  1. Sininger YS, "Auditory brain stem response for objective measures of hearing", Ear Hear, 14, pp.23~30 (1993)
  2. Suthakar K, "A simple algorithm for objective threshold determination of auditory brainstem responses", Hear Res, 381, pp.107782~ (2019)
  3. Verhulst S, "Individual differences in auditory brainstem response wave characteristics : relations to different aspects of peripheral hearing loss", Trends Hear, 20, pp.2331216516672186~ (2016)
  4. Turner K, "Auditory brainstem response wave I amplitude has limited clinical utility in diagnosing tinnitus in humans", Brain Sci, 12, pp.142~ (2022)
  5. van der Drift JF, "The relation between the pure-tone audiogram and the click auditory brainstem response threshold in cochlear hearing loss", Audiology, 26, pp.1~10 (1987)
  6. Hyde ML, "Audiometric estimation error with the ABR in high risk infants", Acta Otolaryngol, 111, pp.212~219 (1991)
  7. Chien CH, "Prediction of the pure-tone average from the speech reception and auditory brainstem response thresholds in a geriatric population", ORL J Otorhinolaryngol Relat Spec, 70, pp.366~372 (2008)
  8. Ball R, "A comparison between Chinese and Caucasian head shapes", Appl Ergon, 41, pp.832~839 (2010)
  9. Ku CH, "Measurement of skull size on computed tomography images for developing a bone conduction headset suitable for the Korean Standard head size", J Audiol Otol, 24, pp.17~23 (2020)
  10. Rosa LA, "Auditory brainstem response : reference-values for age", CoDAS, 26, pp.117~121 (2014)
  11. Beattie RC, "Normative behavioral thresholds for short tone-bursts", J Am Acad Audiol, 12, pp.453~461 (2001)
  12. Suh MJ, "Improving accuracy and reliability of hearing tests : an exploration of international standards", J Audiol Otol, 27, pp.169~180 (2023)
  13. International Electrotechnical Commission, "IEC 60645-7:2009. Electroacoustics–Audiometric equipment - Part 7: instruments for the measurement of auditory brainstem responses", International Electrotechnical Commission, ~ (2009)
  14. International Electrotechnical Commission, "IEC 60645-3:2020. Electroacoustics—Audiometric equipment - Part 3: test signals of short duration", International Electrotechnical Commission, ~ (2020)
  15. Kileny P, "The frequency specificity of tone-pip evoked auditory brain stem responses", Ear Hear, 2, pp.270~275 (1981)
  16. Pinto FR, "A comparison between hearing and tone burst electrophysiological thresholds", Braz J Otorhinolaryngol, 73, pp.513~522 (2007)
  17. Wang X, "Normal reference values of low frequency specific air-conducted auditory brainstem responses among normal hearing children of different ages : a retrospective observational study", Int J Pediatr Otorhinolaryngol, 164, pp.111409~ (2023)
  18. "Pure tone threshold of Korean adults with normal hearing by gender and age" (2023)[URL]
  19. International Electrotechnical Commission, "IEC 60318-1:2009. Electroacoustics—Simulators of human head and ear - Part 1: ear simulator for the measurement of supra-aural and circumaural earphones", International Electrotechnical Commision, ~ (2009)
  20. International Electrotechnical Commission, "IEC 60318-4:2010. Electroacoustics—Simulators of human head and ear - Part 4: occludedear simulator for the measurement of earphones coupled to the ear by means of ear inserts", International Electrotechnical Commission, ~ (2010)
  21. International Electrotechnical Commission, "IEC 60318-6:2007. Electroacoustics—Simulators of human head and ear - Part 6: mechanical coupler for the measurement on bone vibrators", International Electrotechnical Commision, ~ (2007)
  22. Kim S, "Establishment of normative data for auditory brainstem responses in white noise condition", Korean J Otorhinolaryngol-Head Neck Surg, 63, pp.14~20 (2020)
  23. Chun H, "Correlation of acoustic features and electrophysiological outcomes of stimuli at the level of auditory brainstem", J Acoust Soc Korea, 35, pp.63~73 (2016)
  24. Burkard RF, "The human auditory brainstem response to high click rates : aging effects", Am J Audiol, 10, pp.53~61 (2001)
  25. Lichtfuss T, "The auditory brainstem response (ABR): a collection of normative data using the bio-logic AEP system", pp.2016
  26. Polonenko MJ, "The parallel auditory brainstem response", Trends Hear, 23, pp.2331216519871395~ (2019)
  27. Trune DR, "The relative importance of head size, gender and age on the auditory brainstem response", Hear Res, 32, pp.165~174 (1988)
  28. International Organization for Standardization, "ISO 7029:2017. Acoustics—Statistical distribution of hearing thresholds related to age and gender", International Organization for Standardization, ~ (2017)
  29. Jin IK, "Trends in distributions of hearing threshold levels by ages : a comparison of the ISO 7029 and newly available country-specific data", J Audiol Otol, 28, pp.1~9 (2024)

관련 논문AI추천

이 간행물의 다른 논문 (9건)