Seismic fragility analysis of shield building considering strength ratio of mainshock and aftershocks
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The shield building of the AP1000 nuclear power plant serves as a crucial protective barrier against radioactive substances. However, past research indicates that structures are susceptible to experiencing aftershocks, which may lead to unforeseeable damage and potential radioactive material leakage. To address this issue, a finite element model of the shield building was established with the damage indexes of the tensile and compressive damage selected for further model analysis. According to the fundamental theory of reliability, the traditional incremental dynamic analysis method was used to analyze the seismic fragility of the shield building by inputting mainshock and aftershock sequences with three strength ratios. The results indicate that the seismic fragility of shield building may be underestimated without considering the influence of aftershocks and the damage state presents an upward tendency as the strength ratio increases. However, the cumulative damage caused by aftershocks is unlikely to exceed the initial damage induced by the corresponding mainshock. Overall, the aggravation of the compressive damage is less pronounced than the increase of the tensile damage as the strength ratio increases.
Abstract
The shield building of the AP1000 nuclear power plant serves as a crucial protective barrier against radioactive substances. However, past research indicates that structures are susceptible to experiencing aftershocks, which may lead to unforeseeable damage and potential radioactive material leakage. To address this issue, a finite element model of the shield building was established with the damage indexes of the tensile and compressive damage selected for further model analysis. According to the fundamental theory of reliability, the traditional incremental dynamic analysis method was used to analyze the seismic fragility of the shield building by inputting mainshock and aftershock sequences with three strength ratios. The results indicate that the seismic fragility of shield building may be underestimated without considering the influence of aftershocks and the damage state presents an upward tendency as the strength ratio increases. However, the cumulative damage caused by aftershocks is unlikely to exceed the initial damage induced by the corresponding mainshock. Overall, the aggravation of the compressive damage is less pronounced than the increase of the tensile damage as the strength ratio increases.
참고문헌 (37)
- R. Pang, "Stochastic dynamic and reliability analysis of AP1000 nuclear power plants via DPIM subjected to mainshock-aftershock sequences", Reliab. Eng. Syst. Saf, 235 (2023)[DOI]
- F. Pugliese, "Effects of mainshock-aftershock sequences on fragility analysis of RC buildings with ageing", Eng. Struct, 232 (2021)[DOI]
- M. R. Salami, "Influence of advanced structural modelling and subduction mainshock-aftershock sequences on seismic fragility of RC structures", 11th National Conference on Earthquake Engineering 2018:Integrating Science, Engineering, and Policy, NCEE 2018, 2018, pp.24~ (2018)
- Codes for Aseismic Design of Nuclear Power Plants, "J. E. Association", ~, pp.JEAC4601-2008 (2009)
- C. Zhao, "Probabilistic seismic fragility assessment of isolated nuclear power plant structure using IDA and MSA methods", Structures, 34, pp.1300~1311 (2021)[DOI]
- C. Zhao, "Vulnerability assessment of AP1000NPP under mainshock-aftershock sequences", Engineering Structures, 208, pp.110348~ (2020)[DOI]
- J. Shen, "Nonlinear dynamic analysis of frame-core tube building under seismic sequential ground motions by a supercomputer", Soil Dynam. Earthq. Eng., 124, pp.86~97 (2019)[DOI]
- L. Di Sarno, "Fragility assessment of existing low-rise steel momentresisting frames with masonry infills under mainshock-aftershock earthquake sequences", Bull. Earthq. Eng., 19(6), pp.2483~2504 (2021)[DOI]
- C. Amadio, "The effects of repeated earthquake ground motions on the non-linear response of SDOF systems", Earthq. Eng. Struct. Dynam., 32(2), pp.291~308 (2003)[DOI]
- W. Wen, "Damage spectra of global crustal seismic sequences considering scaling issues of aftershock ground motions", Earthq. Eng. Struct. Dynam., 47(10), pp.2076~2093 (2018)[DOI]
- X. Yu, "Development of fragility surfaces for reinforced concrete buildings under mainshock-aftershock sequences", Earthq. Eng. Struct. Dynam., 50(15), pp.3981~4000 (2021)[DOI]
- X. Yu, "Incremental damage analysis of nonlinear single-degree-freedom systems subjected to mainshock-aftershock earthquake sequences", Eng. Mech., 36(3), pp.121~130 (2019)[DOI]
- E. Omranian, "Fragility curve development for the seismic vulnerability assessment of retrofitted RC bridges under mainshock-aftershock seismic sequences", Structures Congress, pp.308~316 (2018)
- J. Ghosh, "Parameterized seismic reliability assessment and life-cycle analysis of aging highway bridges", pp.2013
- Q. Li, "Performance evaluation and damage assessment of steel frame buildings under main shock-aftershock earthquake sequences", Earthq. Eng. Struct. Dynam., 36(3), pp.405~427 (2007)[DOI]
- C.A. Cornell, "Probabilistic basis for 2000SAC federal emergency management agency steel moment frame guidelines", Journal of Structural Engineering-ASCE, 128(4) (2000)[DOI]
- C. Zhao, "Seismic fragility assessment on the postmainshock damaged shield building considering aftershock duration and damage ratio", Bull. Earthq. Eng., 20, pp.6047~6074 (2022)[DOI]
- Standard User’s Manual Version 6.9., "ABAQUS", pp.2009, M. Smith
- J Lubliner, "A plastic-damage model for concrete", Int. J. Solid Struct, 25, pp.299~326 (1989)
- D. Wang, "Elastic-plastic behavior of AP1000nuclear island structure under mainshock-aftershock sequences", Ann. Nucl. Energy, 123, pp.1~17 (2018)[DOI]
- R. H. Li, "Improved estimation on seismic behavior of RC column members: a probabilistic method considering dynamic effect and structural parameter uncertainties", Struct. Saf, 101 (2023)[DOI]
- Q. Wang, "Sesimic responses of CPR1000 safety building on rigid foundation", Low Temp Archit Technol, 10, pp.108~111 (2014)
- J. Chen, "Seismic analysis and evaluation of the base isolation system in AP1000 NI under SSE loading", Nucl. Eng. Des, 278, pp.117~133 (2014)
- C. Zhao, "FSI effects and seismic performance evaluation of water storage tank of AP1000 subjected to earthquake loading", Nucl. Eng. Des, 280, pp.372~388 (2014)[DOI]
- Li. Yuanjun, "Codes on the Safety of Nuclear Power Plants in Relation to Seismic Design", Applied Mechanics and Materials, 256-259, pp.2085~2090 (2013)[DOI]
- "ASCE4-98, Seismic analysis of safety-related nuclear structures and commentary", American Society of Civil, Engineers publication, ~ (2000)
- J. Ruiz-García, "Evaluation of drift demands in existing steel frames under as-recorded far-field and near-fault mainshock–aftershock seismic sequences", Eng. Struct., 33(2), pp.621~634 (2011)[DOI]
- K. Goda, "Nonlinear response potential of mainshock-aftershock sequences from Japanese earthquakes", Bull. Seismol. Soc. Am., 102(5), pp.2139~2156 (2012)[DOI]
- M. Alembagheri, "Damage assessment of a concrete arch dam through nonlinear incremental dynamic analysis", Soil Dynam. Earthq. Eng., 44, pp.127~137 (2013)
- Y. Huang, "Scaling earthquake ground motions for performance-based assessment of buildings", J. Struct. Eng., 137(3), pp.311~321 (2011)[DOI]
- X. Liu, "Seismic fragility analysis of the transfer and purging chamber in a nuclear power plant based on incremental dynamic analysis", Journal of Radiation Research and Applied Sciences, 15(3), pp.133~141 (2022)[DOI]
- F. Sidoroff, "Description of Anisotropic Damage Application to Elasticity", Physical Non-linearities in Structural Analysis: Symposium Senlis, pp.27~30 (1981), Springer
- W. Chen, "Seismic fragility analysis of nuclear power plants based on the substructure method", Nucl. Eng. Des., 382, pp.111389~ (2021)[DOI]
- European Seismological: European Macroseismic Scale 1998 (EMS-98), "G. Grünthal", European Seismological, ~ (1998)
- X. Gu, "Basic Principles of Concrete Structures" (2016), Springer
- C. Z. A. C, "Vulnerability assessment of AP1000 NPP under mainshock-aftershock sequences", Eng. Struct, 208 (2020)[DOI]
- Z. Guo, "Principle and Analysis of Reinforced Concrete" (2003), Tsinghua University Publication