Research on a novel γ-ray spectrum analysis method for low- and intermediate-level radioactive solid waste in nuclear power plants

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Accurate nuclide identification in γ-spectrum analysis of low- and intermediate-level radioactive waste with high-purity germanium detectors necessitates initial forced fitting with a nuclide library, yet inaccuracies in library data may lead to misidentification and missing nuclides. To this end, background clipping strategies were hereby analyzed, and a novel deconvolution spectrum analysis method was proposed, which utilized continuous wavelet transform for peak searching and Gaussian first-order derivative quadratic convolution for calculating peak width. Furthermore, to effectively realize the nuclide identification and peak area calculation, a response filter function model was established through the peak shape calibration. By eliminating the need for nuclide library parameter settings prior to overlapping peak separation, the issue of inaccurate matching arising from reliance on the precision of the nuclide library was addressed. Moreover, spectrum analysis experiments were carried out on standard point sources and 200 L drums, and the results were compared and analyzed using GammaVision. Compared to the GammaVision results set by the accurate nuclide library, the area error of strong peaks decreased from 27.5 % to 4.82 %, while that of weak peaks witnessed a decline from 49.98 % to 27.5 %. Finally, the accuracy of the proposed method was verified using the Pakistan Nuclear Library

Abstract

Accurate nuclide identification in γ-spectrum analysis of low- and intermediate-level radioactive waste with high-purity germanium detectors necessitates initial forced fitting with a nuclide library, yet inaccuracies in library data may lead to misidentification and missing nuclides. To this end, background clipping strategies were hereby analyzed, and a novel deconvolution spectrum analysis method was proposed, which utilized continuous wavelet transform for peak searching and Gaussian first-order derivative quadratic convolution for calculating peak width. Furthermore, to effectively realize the nuclide identification and peak area calculation, a response filter function model was established through the peak shape calibration. By eliminating the need for nuclide library parameter settings prior to overlapping peak separation, the issue of inaccurate matching arising from reliance on the precision of the nuclide library was addressed. Moreover, spectrum analysis experiments were carried out on standard point sources and 200 L drums, and the results were compared and analyzed using GammaVision. Compared to the GammaVision results set by the accurate nuclide library, the area error of strong peaks decreased from 27.5 % to 4.82 %, while that of weak peaks witnessed a decline from 49.98 % to 27.5 %. Finally, the accuracy of the proposed method was verified using the Pakistan Nuclear Library

참고문헌 (45)

  1. Interim storage of radioactive waste packages, , International Atomic Energy Agency, 390~ (1998)
  2. H. Yang, "Transmission reconstruction algorithm by combining maximumlikelihood expectation maximization and a convolutional neural network for radioactive drum characterization", Appl. Radiat. Isot, 184, pp.110172~ (2022)[DOI]
  3. "Classification of radioactive waste, in: General Safety Guides, No. GSG-1" (2009)[URL]
  4. J. S. Hansen, "Application Guide to Tomographic Gamma Scanning of Uranium and Plutonium", 57~
  5. Test Method for Nondestructive Assay of Special Nuclear Material in Low-Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning, "C26 Committee", ASTM International, ~
  6. C26 Committee, "Nondestructive Assay of Radioactive Material by Tomographic Gamma Scanning", ~
  7. Terminology of C26.10 Nondestructive Assay Methods, "C26 Committee", ASTM International, ~
  8. Mona M. Gouda, "Calibration of well-type NaI(Tl)detector using a point sources measured out the detector well at different axial distances", J. Instrum, 10, pp.P03022~ (2015)
  9. Ahmed M. El-Khatib, "New analytical approach to calibrate the NaI (Tl) detectors using spherical radioactive sources", Radiat. Protect. Dosim, 156(1), pp.109~117 (2013)
  10. Mohamed Badawi, "Calibration of 4π NaI(Tl)detectors with coincidence summing correction using new numerical procedure and ANGLE4 software", AIP Adv, 7, pp.035005~ (2017)
  11. Ahmed M. El-Khatib, "Abbas,Welltype NaI(Tl) detector efficiency using analytical technique and ANGLE 4 software based on radioactive point sources located out the well cavity", Chin. J. Phys, 54(3), pp.338~346 (2016)
  12. J. L. Parker, "The Use of Calibration Standards and the Correction for Sample SelfAttenuation in Gamma-Ray Nondestructive Assay", 35~
  13. "EN ISO 19017, Guidance for gamma spectrometry measurement of radioactive waste (ISO 19017:2015)" (2017)[URL]
  14. H. Yang, "A novel method for gamma spectrum analysis of low-level and intermediate-level radioactive waste", Nucl. Sci. Tech, 34(6), pp.87~ (2023)[DOI]
  15. H. Yang, "Research on the CdZnTe γspectrum analysis based on an intelligent dynamic library", J. Radioanal. Nucl. Chem (2023)[DOI]
  16. S.J. Bell, "A comparison of emerging gamma detector technologies for airborne radiation monitoring", J. Phys.: Conf. Ser, 763, pp.012010~ (2016)[DOI]
  17. D. N. Grozdanov, "Semi-empirical gamma-ray response function of BGO, NaI (Tl) and LaBr 3 (Ce) scintillation detectors, Nucl. Instrum", Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 1014, pp.165741~ (2021)[DOI]
  18. Mona M. Gouda, "Mathematical method to calculate full-energy peak efficiency of detectors based on transfer technique", Indian J. Phys, 90, pp.201~210 (2016)
  19. Mohamed S. Badawi, "New numerical simulation approach to calibrate the NaI(Tl)detectors array using non-axial extended spherical sources", J. Instrum, 8, pp.11005~ (2013)
  20. Abouzeid Thabet, "Experimental verification of gammaefficiency calculations for scintillation detectors in ANGLE 4 software", Nucl. Technol. Radiat. Protect, 30, pp.35~46 (2015)
  21. M. S. Badawi, "Characterization of the efficiency of a cubic NaI detector with rectangular cavity for axially positioned sources", J. Instrum, 15(2), pp.P02013~ (2020)
  22. Mohamed Badawi, "A numerical simulation method for calculation of linear attenuation coefficients of unidentified sample materials in routine gamma ray spectrometry", Nucl. Technol. Radiat. Protect, 30, pp.249~259 (2015)
  23. G. F. Knoll, "Radiation Detection and Measurement" (2010), John Wiley
  24. "PART 61—LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE"[URL]
  25. M.A. Mariscotti, "A method for automatic identification of peaks in the presence of background and its application to spectrum analysis", Nucl. Instrum. Methods, 50(2), pp.309~320 (1967)[DOI]
  26. I.A. Slavi´c, "A simple method for full automatic gamma-ray spectra analysis", Nucl. Instrum. Methods, 84(2), pp.261~268 (1970)[DOI]
  27. A. Robertson, "An automatic peak-extraction technique", Nucl. Instrum. Methods, 100(2), pp.317~324 (1972)[DOI]
  28. I.A. Slavi´c, "Automatic analysis of gamma-ray spectra", Nucl. Instrum. Methods, 112(1–2), pp.253~260 (1973)[DOI]
  29. H.P. Blok, "A new peak search method for an automatic spectrum analysis program", Nucl. Instrum. Methods, 128(3), pp.545~556 (1975)[DOI]
  30. C.J. Sullivan, "Wavelet analysis of gamma-ray spectra", IEEE Symposium Conference Record Nuclear Science 2004, pp.281~286 (2004), IEEE
  31. S.M. Galib, "A comparative study of machine learning methods for automated identification of radioisotopes using NaI gammaray spectra", Nucl. Eng. Technol, 53(12), pp.4072~4079 (2021)[DOI]
  32. C. Teke, "Prediction of gamma ray spectrum for 22Na source by feed forward back propagation ANN model", Radiat. Phys. Chem, 202, pp.110558~ (2023)[DOI]
  33. Miroslav Morh´aˇc, "Efficient one- and two-dimensional gold deconvolution and its application to γ-ray spectra decomposition", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 401(2–3), pp.385~408 (1997)[DOI]
  34. IAEA, "IAEA Intercomparison of Software Packages", ~ (1998)
  35. "Genie 2000 operations manual"[URL]
  36. M. Kashiwagi, "ISO standardization of the scaling factor method for low- and intermediate level radioactive wastes generated at nuclear power plants", 11th International Conference on Environmental Remediation and Radioactive Waste Management, Parts A and B, pp.625~629 (2007), ASMEDC
  37. C.G. Ryan, "SNIP, a statisticssensitive background treatment for the quantitative analysis of PIXE spectra in geoscience applications", Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 34(3), pp.396~402 (1988)[DOI]
  38. M. Morh´aˇc, "Peak clipping algorithms for background estimation in spectroscopic data", Appl. Spectrosc, 62(1), pp.91~106 (2008)[DOI]
  39. P. Bury, "Wavelet analysis of X-ray spectroscopic data Part I. The method", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 383(2–3), pp.572~588 (1996)[DOI]
  40. C.J. Sullivan, "Wavelet analysis of sodium iodide spectra", IEEE Nuclear Science Symposium Conference Record, 2005, Wyndham El Conquistador Resort, pp.302~306 (2005), IEEE
  41. M. Liu, "An improved method based on a new wavelet transform for overlapped peak detection on spectrum obtained by portable Raman system", Chemometr. Intell. Lab. Syst, 182, pp.1~8 (2018)[DOI]
  42. "IEC 61453:2007 Nuclear instrumentation - scintillation gamma ray detector systems for the assay of radionuclides - calibration androutine testsIEC 61453:2007| IEC Webstore"[URL]
  43. M. Morh´aˇc, "Deconvolution methods and their applications in the analysis of -ray spectra", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 559(1), pp.119~123 (2006)[DOI]
  44. Miroslav Morh´aˇc, "High-resolution boosted deconvolution of spectroscopic data", J. Comput. Appl. Math, 235(6), pp.1629~1640 (2011)[DOI]
  45. H. Yang, "Research on the γspectrum-unfolding method of low- and intermediate-level radioactive waste based on LaBr3(Ce) detector", Radiat. Phys. Chem, pp.110841~ (2023)[DOI]

관련 논문AI추천

Radionuclide identification method for NaI low-count gamma-ray spectra using artificial neural networkHaijun Fan, Hui Zhao, Jinglun Li, Kun Zhang, Shanqiang Wang, Sheng Qi, Xianyun Ai, Ye Chen한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제1호Identification of low-count, low-resolution gamma spectral radionuclide using 2DCNN-BiLSTM neural networkShang Ya-Nan, Shi Rui, Tuo Xian-Guo, Wang Zhou, Yang Guang, Zeng Shu-Xin, Zeng Xiong, Zhang Heng한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제12호Application of wavelet transform in anti-Compton phoswich detector for gamma spectrumBai Xiaohou, E Dejun, Huang Liming, Liu Changqi, Li Weimin, Ma Zhanwen, Peng Jinqiu, Tao Kai한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제10호A method to obtain radioactivity of non-𝛾 nuclides by 60Co based on Monte Carlo simulationsHu Bitao, Liu Zuoye, Shi Yingbo, Sun Shaohua, Su Rongbo, Xiang Yulin한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제10호Explainable radionuclide identification algorithm based on the convolutional neural network and class activation mappingFan Qimeng, Jiang Nan, Lu Yunfeng, Wang Yu, Yao Qingxu, Yu Wangtao, Zhang He, Zhang Quanhu한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제12호Radioisotope identification using sparse representation with dictionary learning approach for an environmental radiation monitoring system김기윤, 김원구, 김준혁, 김진환, 이대희, 조규성, 황지성한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제3호

이 간행물의 다른 논문 (49건)