본문 바로가기
KERD
논문KCI 등재

A rapid and direct method for half value layer calculations for nuclear safety studies using MCNPX Monte Carlo code

0

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Half Value Layer calculations theoretically need prior specification of linear attenuation calculations, since the HVL value is derived by dividing ln(2) by the linear attenuation coefficient. The purpose of this study was to establish a direct computational model for determining HVL, a vital parameter in nuclear radiation safety studies and shielding material design. Accordingly, a typical gamma-ray transmission setup has been modeled using MCNPX (version 2.4.0) general-purpose Monte Carlo code. The MCNPX code's INPUT file was designed with two detection locations for primary and secondary gamma-rays, as well as attenuator material between those detectors. Next, Half Value Layer values of some well-known gamma-ray shielding materials such as lead and ordinary concrete have been calculated throughout a broad gamma-ray energy range. The outcomes were then compared to data from the National Institute of Standards and Technology. The Half Value Layer values obtained from MCNPX were reported to be highly compatible with the HVL values obtained from the NIST standard database. Our results indicate that the developed INPUT file may be utilized for direct computations of Half Value Layer values for nuclear safety assessments as well as medical radiation applications. In conclusion, advanced simulation methods such as the Monte Carlo code are very powerful and useful instruments that should be considered for daily radiation safety measures. The modeled MCNPX input file will be provided to the scientific community upon reasonable request.

Abstract

Half Value Layer calculations theoretically need prior specification of linear attenuation calculations, since the HVL value is derived by dividing ln(2) by the linear attenuation coefficient. The purpose of this study was to establish a direct computational model for determining HVL, a vital parameter in nuclear radiation safety studies and shielding material design. Accordingly, a typical gamma-ray transmission setup has been modeled using MCNPX (version 2.4.0) general-purpose Monte Carlo code. The MCNPX code's INPUT file was designed with two detection locations for primary and secondary gamma-rays, as well as attenuator material between those detectors. Next, Half Value Layer values of some well-known gamma-ray shielding materials such as lead and ordinary concrete have been calculated throughout a broad gamma-ray energy range. The outcomes were then compared to data from the National Institute of Standards and Technology. The Half Value Layer values obtained from MCNPX were reported to be highly compatible with the HVL values obtained from the NIST standard database. Our results indicate that the developed INPUT file may be utilized for direct computations of Half Value Layer values for nuclear safety assessments as well as medical radiation applications. In conclusion, advanced simulation methods such as the Monte Carlo code are very powerful and useful instruments that should be considered for daily radiation safety measures. The modeled MCNPX input file will be provided to the scientific community upon reasonable request.

참고문헌 (36)

  1. D. Adliene, "Occupational radiation exposure of health professionals and cancer risk assessment for Lithuanian nuclear medicine workers", Environ. Res, 183, pp.109144~ (2020)[DOI]
  2. K. F. Salama, "Assessment of occupational radiation exposure among medical staffin health-care facilities in the Eastern Province, Kingdom of Saudi Arabia", Indian J. Occup. Environ. Med, 20, pp.21~ (2016)[DOI]
  3. C. Heilmaier, "Improving Radiation Awareness and Feeling of Personal Security of Non-Radiological Medical Staffby Implementing a Traffic Light System in Computed Tomography", RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 188(03), pp.280~287 (2016), Georg Thieme Verlag KG[DOI]
  4. P. M. Maina, "Investigation of radiation protection and safety measures in Rwandan public hospitals : readiness for the implementation of the new regulations", J. Med. Imag. Radiat. Sci, 51, pp.629~638 (2020)[DOI]
  5. 신재민, "A Survey of the Radiation Exposure Protection of Health Care Providers during Endoscopic Retrograde Cholangiopancreatography in Korea", Gut and Liver, 7(1), pp.100~105 (2013), 거트앤리버 소화기연관학회협의회
  6. W. R. Hendee, "ALARA and an integrated approach to radiation protection", Semin. Nucl. Med, 16, pp.142~150 (1986)[DOI]
  7. Maurice Junda, "Local diagnostic reference levels for routine chest X-ray examinations at a public sector hospital in central South Africa", Health SA Gesondheid, 26 (2021), AOSIS[DOI]
  8. D. Z. Solomon, "Justification and optimization principles of ALARA in pediatric CT at a teaching hospital in Ethiopia", Ethiop. J. Health Sci, 30, pp.761~766 (2020)[DOI]
  9. J. V. Vitola, "Opportunities for improvement on current nuclear cardiology practices and radiation exposure in Latin America : findings from the 65-country IAEA Nuclear Cardiology Protocols cross-sectional Study(INCAPS)", J. Nucl. Cardiol, 24, pp.851~859 (2017)[DOI]
  10. A. Mukherji, "Time, distance, shielding and ALARA;Drawing similarities between measures for radiation protection and Coronavirus disease pandemic response", Indian J. Cancer, 57, pp.221~223 (2020)[DOI]
  11. 김재헌, "Three principles for radiation safety: time, distance, and shielding", The Korean Journal of Pain, 31(3), pp.145~146 (2018), 대한통증학회
  12. H. Schlattl, "Shielding properties of lead-free protective clothing and their impact on radiation doses", Med. Phys, 34, pp.4270~4280 (2007)[DOI]
  13. G. Lakshminarayana, "Binary B2O3eBi2O3 glasses : scrutinization of directly and indirectly ionizing radiations shielding abilities", J. Mater. Res. Technol, 9, pp.14549~14567 (2020)[DOI]
  14. G. Lakshminarayana, "In-depth survey of nuclear radiation attenuation efficacies for high density bismuth lead borate glass system", Results Phys, 23, pp.104030~ (2021)[DOI]
  15. H. O. Tekin, "A systematical characterization of teo2ev2o5 glass system using boron(Iii)oxide and neodymium(iii)oxide substitution : resistance behaviors against ionizing radiation", Appl. Sci, 11, pp.3035~ (2021)[DOI]
  16. Ghada ALMisned, "Trivalent Ions and Their Impacts on Effective Conductivity at 300 K and Radio-Protective Behaviors of Bismo-Borate Glasses: A Comparative Investigation for Al, Y, Nd, Sm, Eu", Materials, 14(19), pp.5894~ (2021), MDPI AG[DOI]
  17. K. Matsubara, "Method for determining the half-value layer in computed tomography scans using a realtime dosimeter : application to dual-source dual-energy acquisition", Phys. Med, 44, pp.227~231 (2017)[DOI]
  18. T. Gotanda, "Half-value layer measurement : simple process method using radiochromic film", Australas. Phys. Eng. Sci. Med, 32, pp.150~158 (2009)[DOI]
  19. R. Ishii, "Precision of half-value layer measurement on mammography", Nippon. Hoshasen Gijutsu Gakkai Zasshi, 67, pp.1533~1539 (2011)[DOI]
  20. ", Zhonghua Kou Qiang Yi Xue Za Zhi 46" (2011)[URL]
  21. Ghada ALMisned, "Gamma-Ray Protection Properties of Bismuth-Silicate Glasses against Some Diagnostic Nuclear Medicine Radioisotopes: A Comprehensive Study", Materials, 14(21), pp.6668~ (2021), MDPI AG[DOI]
  22. Hesham MH. Zakaly, "Role of novel ternary nanocomposites polypropylene in nuclear radiation attenuation properties: In-depth simulation study", Radiation Physics and Chemistry, 188, pp.109667~ (2021), Elsevier BV[DOI]
  23. Erkan Ilik, "A closer-look on Copper(II) oxide reinforced Calcium-Borate glasses: Fabrication and multiple experimental assessment on optical, structural, physical, and experimental neutron", gamma shielding properties, 2022, pp.48(5), 6780~6791[DOI]
  24. A. Fukuda, "Measurement of the half-value layer for CT systems in a single-rotation technique : reduction of stray radiation with lead apertures", Phys. Med, 76, pp.221~226 (2020)[DOI]
  25. G. ALMisned, "Enhancement of gamma-ray shielding properties in cobalt-doped heavy metal borate glasses : the role of lanthanum oxide reinforcement", Materials(Basel), 14, pp.7703~ (2021)[DOI]
  26. H. O. Tekin, "Multiple assessments on the gamma-ray protection properties of niobium-doped borotellurite glasses : a wide range investigation using Monte Carlo simulations", Sci. Technol. Nucl. Install, 2022, pp.1~17 (2022)[DOI]
  27. Hesham M.H. Zakaly, "Nuclear shielding performances of borate", sodium, Journal of Materials Research and Technology, pp.2022, 18[DOI]
  28. Hesham M.H. Zakaly, "Alteration of optical, structural, mechanical durability and nuclear radiation attenuation properties of barium borosilicate glasses through BaO reinforcement: Experimental and numerical analyses", Ceramics International, 47(4), pp.5587~5596 (2021), Elsevier BV[DOI]
  29. Rashad M., "Physical and nuclear shielding properties of newly synthesized magnesium oxide and zinc oxide nanoparticles", Nuclear Engineering and Technology, 52(9), pp.2078~2084 (2020), 한국원자력학회[DOI]
  30. H. O. Tekin, "Transmission factor(TF)behavior of Bi2O3-eTeO2eNa2OeTiO2eZnO glass system : a Monte Carlo simulation study", Sustainability, 14, pp.2893~ (2022)[DOI]
  31. H.O. Tekin, "Heavy metal oxide (HMO) glasses as an effective member of glass shield family: A comprehensive characterization on gamma ray shielding properties of various structures", Journal of Materials Research and Technology, 18, pp.231~244 (2022), Elsevier BV[DOI]
  32. Hesham M.H. Zakaly, "An experimental evaluation of CdO", PbO-B2O3 glasses containing neodymium oxide: Structure, electrical conductivity, and gamma-ray resistance, 2022, pp.151, 111828~[DOI]
  33. "XCOM: Photon Cross Section Database (version 1.5)" (2010)[URL]
  34. "NIST Standard Reference Database 8 (XGAM), XCOM Phot. Cross Sect. Database" (2018)[URL]
  35. H.A. Saudi, "Exploration of material characteristics of tantalum borosilicate glasses by experimental, simulation, and theoretical methods", Journal of Physics and Chemistry of Solids, 159, pp.110282~ (2021), Elsevier BV[DOI]

관련 논문AI추천

A Comprehensive study on the γ-ray shielding performance of Al–Cu–PbO alloy: Experimental and simulation studiesHamood Mahmood Ahmed, Mahmoud K.A., Majeed Enas Ismail, Najam Laith Ahmed한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제1호MCNP 시뮬레이션을 통한 450 kVp 엑스레이 튜브의 콘크리트 차폐벽 두께 계산 및 반가층 방법을 이용한 계산과의 결과 비교김찬규, 이상헌, 이은중, 조규성, 허삼석(사)한국방사선산업학회 · 방사선산업학회지2016 · 제10권 제1호Extensive analysis of several Indian and Yemeni soils' gamma-ray shielding characteristics: An experimental and simulation approachAlameen A.S., Gaikwad D.K., Mahmoud K.A., Obaid Shamsan S., Sayyed M.I.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제9호Understanding radiation shielding performance through a comparative study of half value layer in novel and preexisting silicate glassesAlbarzan B., Almuqrin Aljawhara H., Alrowaily Albandari.W., Sayyed M.I.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제3호A comprehensive evaluation of Mg-Ni based alloys radiation shielding features for nuclear protection applicationsKaky Kawa M., Mahmoud K.A., Mohammed Faras Q., Sayyed M.I.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제5호Geant4 comprehensive evaluation of polystyrene-tungsten (VI) oxide composites for gamma and neutron radiation shielding enhancementAkhdar Hanan, Aminu Bashir Garba, Kipkosgei C Amos, Liu Yong-Kuo한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호

이 간행물의 다른 논문 (20건)