The radiological safety of workers in a newly developed microwave-based spent resin treatment facility was assessed based on work location and operational scenarios. The results show that the remoteoperation room worker was exposed to maximum annual dose of 3.19Eþ00 mSv, which is 15.9% of the dose limit, thereby confirming radiological safety. Inside the pathway, annual doses in the range of 7.87E-02e2.07E-01 mSv were measured initially at the mock-up tank and later at the point between the spent resin separation and treatment parts. The dose of emergency maintenance workers was below the dose limit (4.08E-03e4.99Eþ00 mSv); however, before treatment (separation and microwave), the dose of maintenance and repair workers exceeded the dose limit. The doses of the effluent removal workers at the zeolite and activated carbon storage tank and spent resin storage tank were the lowest at 2.79E-01 e2.87E-01 mSv and 9.27E-01 mSv in “1 h” and “4e5 h of operation”, respectively. The immediately lower and upper layers of the facility room exhibited the highest annual doses of 1.84Eþ00 and 3.22Eþ00 mSv, respectively. Through this study, a scenario that can minimize the dose considering the movement of spent resin through the facility can be developed

Abstract

The radiological safety of workers in a newly developed microwave-based spent resin treatment facility was assessed based on work location and operational scenarios. The results show that the remoteoperation room worker was exposed to maximum annual dose of 3.19Eþ00 mSv, which is 15.9% of the dose limit, thereby confirming radiological safety. Inside the pathway, annual doses in the range of 7.87E-02e2.07E-01 mSv were measured initially at the mock-up tank and later at the point between the spent resin separation and treatment parts. The dose of emergency maintenance workers was below the dose limit (4.08E-03e4.99Eþ00 mSv); however, before treatment (separation and microwave), the dose of maintenance and repair workers exceeded the dose limit. The doses of the effluent removal workers at the zeolite and activated carbon storage tank and spent resin storage tank were the lowest at 2.79E-01 e2.87E-01 mSv and 9.27E-01 mSv in “1 h” and “4e5 h of operation”, respectively. The immediately lower and upper layers of the facility room exhibited the highest annual doses of 1.84Eþ00 and 3.22Eþ00 mSv, respectively. Through this study, a scenario that can minimize the dose considering the movement of spent resin through the facility can be developed

참고문헌 (18)

  1. W. Feng, "Decomposition of spent radioactive ionexchange resin using photo-Fenton process", J. Chem. Technol. Biotechnol, 95, pp.2522~2529 (2020)
  2. N. H. Hamodi, "Immobilization of spent ion exchange resin arising from nuclear power plants : an introduction", J. Pak. Mater. Soc, 3, pp.7~18 (2009)
  3. A. Hussain, "Treatment and conditioning of spent ion exchange resin from nuclear power plant", Adv. Theor. Math. Phys, 15, pp.79~89 (2013)
  4. Management of spent ionexchange resins from nuclear power plants, "International Atomic Energy Agency", ~, pp.TECDOC 2380 (1981)
  5. K. Kim, "Treatment of ion exchange resins used in nuclear power plants by super-and sub-critical water oxidationeA road to commercial plant from bench-scale facility", Chem. Eng. J, 189, pp.213~221 (2012)
  6. Y. P. Korchagin, "Improvement of technology for treatment of spent radioactive ion-exchange resins at nuclear power stations", Therm. Eng, 57, pp.593~597 (2010)
  7. T.B. Tahir, "Radioactive waste management: policy & strategy of Pakistan", Conference of World Nuclear Association (2007)
  8. L. Wang, "Experimental investigation on gasification of cationic ion exchange resin used in nuclear power plants by supercritical water", J. Hazard Mater, 126437 (2021)
  9. On the Swelling of Ion Exchange Resins Used in Swedish Nuclear Power Plants, "A.C. Nilsson", Swedish Nuclear Power Inspectorate, ~, pp.No. SKI–84089 (1988)
  10. M. S. Palamarchuk, "Decontamination of spent ion-exchange resins contaminated with cesium radionuclides", Dokl. Chem, 465, pp.308~312 (2015)
  11. Z. Wan, "Treatment of spent radioactive anionic exchange resins using Fenton-like oxidation process", Chem. Eng. J, 284, pp.733~740 (2016)
  12. M. A. Hafeez, "Fenton-like treatment for reduction of simulated carbon-14 spent resin", J. Environ. Chem. Eng, 9, pp.104740~ (2021)
  13. Development of Adsorbent for C-14 Gas Trapping and Characteristics Evaluation, "G. I. Park", ~ (2006)
  14. J. Wang, "Treatment and disposal of spent radioactive ion-exchange resins produced in the nuclear industry", Prog. Nucl. Energy, 78, pp.47~55 (2015)
  15. J. Li, "Advances in cement solidification technology for waste radioactive ion exchange resins : a review", J. Hazard Mater, 135, pp.443~448 (2006)
  16. I. Plecas, "Influence of natural sorbents on the immobilization of spent ion exchange resins in cement", J. Radioanal. Nucl. Chem, 269, pp.181~185 (2006)
  17. 변재훈, "Dose evaluation of workers according to operating time and outfl ow rate in a spent resin treatment facility", Nuclear Engineering and Technology, 53(11), pp.3824~3836 (2021), 한국원자력학회[DOI]
  18. Development of the VISIPLAN ALARA Planning Tool, "F. Vermeersch", ~, pp.No. IAEA-TECDOC–1031 (1998)

관련 논문AI추천