A 100 kW thermal power pool-type light water reactor and Pu(Be) as a fast neutron source were used to determine the appropriate carrier for irradiating boron-containing samples with neutron beams. The tested materials (carriers) were subjected to neutron beams in the reactor's tangential channel. The geometrical arrangement of experimental facilities relative to the neutron beam trajectory, as well as the effect of sample thickness on the count rate, were investigated. The majority of the detectable charged particles emitted by the neutron beam's interaction with tested materials and the detector's detecting layer are protons (recoiled hydrogen) and particles generated in nuclear reactions (protons and alpha particles), respectively. Stopping and Range of Ions in Matter (SRIM) software was used to do theoretical calculations for the range of expected released particles in various materials, including human tissue. The results of measurement and calculation are in good agreement. According to experiments and theoretical calculations, the number of protons emitted by tissue-like materials may commit a dose comparable to that of boron capture reactions. Furthermore, the range of protons is significantly larger than that of alpha particles, which most probably changes dose distribution in healthy cells surrounding the tumor, which is undesirable in the BNCT approach

Abstract

A 100 kW thermal power pool-type light water reactor and Pu(Be) as a fast neutron source were used to determine the appropriate carrier for irradiating boron-containing samples with neutron beams. The tested materials (carriers) were subjected to neutron beams in the reactor's tangential channel. The geometrical arrangement of experimental facilities relative to the neutron beam trajectory, as well as the effect of sample thickness on the count rate, were investigated. The majority of the detectable charged particles emitted by the neutron beam's interaction with tested materials and the detector's detecting layer are protons (recoiled hydrogen) and particles generated in nuclear reactions (protons and alpha particles), respectively. Stopping and Range of Ions in Matter (SRIM) software was used to do theoretical calculations for the range of expected released particles in various materials, including human tissue. The results of measurement and calculation are in good agreement. According to experiments and theoretical calculations, the number of protons emitted by tissue-like materials may commit a dose comparable to that of boron capture reactions. Furthermore, the range of protons is significantly larger than that of alpha particles, which most probably changes dose distribution in healthy cells surrounding the tumor, which is undesirable in the BNCT approach

참고문헌 (49)

  1. M. Balcerzyk, "Quantification of boron compound concentration for BNCT using positron emission Tomography", Cells, 9, pp.1~11 (2020)[DOI]
  2. Minoru Suzuki, "Boron neutron capture therapy (BNCT): a unique role in radiotherapy with a view to entering the accelerator-based BNCT era", International Journal of Clinical Oncology, 25(1), pp.43~50 (2019), Springer Science and Business Media LLC[DOI]
  3. J. A. Coderre, "The radiation biology of boron neutron capture therapy", Radiat. Res, 151, pp.1~18 (1999)
  4. G. M. Morris, "Response of the central nervous system to boron neutron capture irradiation : evaluation using rat spinal cord model", Radiother. Oncol, 32, pp.249~255 (1994)
  5. G. Ichikawa, "Development of thermal neutron moderator for testing boron agents for boron neutron capture therapy (BNCT)", J. Instrum, 14, pp.1~11 (2019)
  6. Koji Ono, "Prospects for the new era of boron neutron capture therapy and subjects for the future", Therapeutic Radiology and Oncology, 2, pp.40~40 (2018), AME Publishing Company[DOI]
  7. Leena Kankaanranta, "Boron neutron capture therapy (BNCT) followed by intensity modulated chemoradiotherapy as primary treatment of large head and neck cancer with intracranial involvement", Radiotherapy and Oncology, 99(1), pp.98~99 (2011), Elsevier BV[DOI]
  8. T. Aihara, "BNCT for advanced or recurrent head and neck cancer", Appl. Radiat. Isot, 88, pp.12~15 (2014)
  9. T. Aihara, "Fatal carotid blowout syndrome after BNCT for head and neck cancers", Appl. Radiat. Isot, 88, pp.202~206 (2015)
  10. L. W. Wang, "Fractionated BNCT for locally recurrent head and neck cancer : experience from a phase I", II clinical trial at tsing hua open-pool reactor, 2014, pp.88, 64~68
  11. Ling‐Wei Wang, "Clinical trials for treating recurrent head and neck cancer with boron neutron capture therapy using the Tsing‐Hua Open Pool Reactor", Cancer Communications, 38(1), pp.1~7 (2018), Wiley[DOI]
  12. Rolf F Barth, "Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer", Radiation Oncology, 7(1), pp.146~167 (2012), Springer Science and Business Media LLC[DOI]
  13. Huifang He, "The basis and advances in clinical application of boron neutron capture therapy", Radiation Oncology, 16(1), pp.1~8 (2021), Springer Science and Business Media LLC[DOI]
  14. G. L. Locher, "Biological effects and therapeutic possibilities of neutrons", Journal Roentgenol Radium Therapy, 36, pp.1~13 (1936)
  15. Marina Carpano, "Experimental studies for the personalized application of boron neutron capture therapy to the treatment of cutaneous melanoma", Therapeutic Radiology and Oncology, 5, pp.1~11 (2021), AME Publishing Company[DOI]
  16. G. M. Morris, "Response of rat skin to boron neutron capture therapy with p-boronophenylalanine or borocaptate sodium", Radiother. Oncol, 32, pp.144~153 (1994)
  17. Rolf F. Barth, "Boron delivery agents for neutron capture therapy of cancer", Cancer Communications, 38(1), pp.1~15 (2018), Wiley[DOI]
  18. Rolf F. Barth, "Boron Neutron Capture Therapy of Cancer: Current Status and Future Prospects", Clinical Cancer Research, 11(11), pp.3987~4002 (2005), American Association for Cancer Research (AACR)[DOI]
  19. Feng-Yi Yang, "Micro-SPECT", CT–Based Pharmacokinetic Analysis of <sup>99m<, Journal of Nuclear Medicine, pp.2011, 52(3)[DOI]
  20. K. Hanaoka, "FBPA PET in boron neutron capture therapy for cancer: prediction of 10B concentration in the tumor and normal tissue in a rat xenograft model", EJNMMI Res, 4, pp.70~79 (2014)
  21. Y. Imahori, "Advances in brief positron emission Tomography based boron neutron capture therapy using boronophenylalanine for high grade gliomas : Part-I", Clin. Cancer Res, 4, pp.1825~1832 (1998)
  22. D. Skwierawska, "Physical Bases of Boron Neutron Capture Therapy, Dosimetry, and its Mechanisms of Action - a Critical Overview of the Literature", 1, pp.1~19 (2021)[DOI]
  23. H. Fukuda, "Pharmacokinetics of 10 B - p - boronophenylalanine in tumours, skin and blood of melanoma patients: a study of boron neutron capture therapy for malignant melanoma", Melanoma Res, 9, pp.75~83 (1999)
  24. T. Morita, "Dynamic changes in 18F-Borono-L-Phenylalanine uptake in unresectable, advanced, or recurrent squamous cell carcinoma of the head and neck and malignant melanoma during boron neutron capture therapy patient selection", Radiat. Oncol, 13, pp.1~6 (2018)
  25. Y. Imahori, "Positron emission tomography-based boron neutron capture therapy using boronophenylalanine for high-grade gliomas: Part II", Clin. Cancer Res, 4, pp.1833~1841 (1998)
  26. Teruhito Aihara, "First clinical case of boron neutron capture therapy for head and neck malignancies using 18F-bpa PET", Head &amp; Neck, 28(9), pp.850~855 (2006), Wiley[DOI]
  27. Requirements for Boron Neutron Capture Therapy (BNCT) at a Nuclear Research Reactor, "W. Sauerwein", The European BNCT Project-Joint Research Centre, Institute for Energy and Transport, Publications Office, ~ (2013)
  28. E.M. Zsolnay, "Thermal neutron field for BNCT experiments at the nuclear reactor of TUB", Proceedings of the 7th International Symposium on Neutron Capture Therapy for Cancer (1996)
  29. BNCT Programme in Hungary, Requirements for Boron Neutron Capture Therapy (BNCT) at a Nuclear Research Reactor, "E.M. Zsolnay", 95~97, pp.The European BNCT Project EUR 23830 EN (2009)
  30. G.Y. Csom, "Investigation of neutron beams for the realization of boron neutron capture therapy", Proceedings of an International Workshop on Neutron Beam Design. Development. And Performance for Neutron Capture Therapy, at the Massachusetts Institute of Technology, pp.141~151 (1989)
  31. Benchmark Description of the BME Training Reactor, "G. Klujber", Budapest University of Technology and Economics, Institute of Nuclear Techniques, ~, pp.BME-NTI-854 (2019), 2018 v3.2
  32. B.K. Seo, "Evaluation of Thin ZnS(Ag) Scintillator Sheet for Alpha-Ray Contamination Monitoring during Decommissioning", Transactions of the Korean Nuclear Society Autumn Meeting Busan (2005)
  33. S. K. Lee, "Comparison of new simple methods in fabricating ZnS(Ag) scintillators for detecting alpha particles", Progress in Nuclear Science and Technology, 1, pp.194~197 (2011)
  34. R. Shweikani, "Preliminary study on the properties of zinc oxide(zno)for alpha particles detection", International Journal of Radiation Research, 15, pp.302~306 (2017)
  35. M. A. Misdaq, "A new method for determining the radon emanation coefficients and radon production rates in different building materials using solid state nuclear track detectors", J. Radioanal. Nucl. Chem, 218, pp.9~12 (1997)
  36. "ZnS(Ag) zinc sulfide scintillation material"[URL]
  37. M. Ardid, "Study of the background on a ZnS(Ag) alpha counter with a plastic veto detector, nuclear instrumentation and methods in physics", Research, 557, pp.510~515 (2006)
  38. G. F. Knoll, "Radiation Detection and Measurement" (1999), John Willey and Sons
  39. Hamamatsu Photonics K.K. editorial committee, "Photomultiplier tubes, basic and applications" (2007), hamamatsu photonics K.K. Electron tube division
  40. G. H. Kim, "Determination of the Optimum Counting Condition of a ZnS(Ag) Scintillation Detector for Contamination Monitoring", Transactions of the Korean Nuclear Society Autumn Meeting Busan (2005)
  41. G. D. Chase, "Principles of Radioisotope Methodology" (1967), Burgess Publishing Company
  42. R. T. Overman, "Radioisotope Techniques" (1960), McGraw-Hill
  43. S. A. McElhaney, "A ruggedized ZnS(Ag)", Epoxy alpha scintillation detector, 1990, pp.299, 111~114
  44. "SA-100TM, Alpha prob, MIRION technologies"[URL]
  45. J. F. Ziegler, "Srim e the stopping and range of ions in matter", Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 268, pp.1818~1823 (2010)
  46. J. F. Ziegler, "The stopping of ions in compounds", Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 35, pp.215~228 (1988)
  47. Xiang Cheng, "Boron Neutron Capture Therapy: Clinical Application and Research Progress", Current Oncology, 29(10), pp.7868~7886 (2022), MDPI AG[DOI]
  48. Kavitaa Nedunchezhian, "Boron Neutron Capture Therapy - A Literature Review", JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 10, pp.ZE01~ZE04 (2016), JCDR Research and Publications[DOI]
  49. F.H. Attix, "Introduction to Radiological Physics and Radiation Dosimetry Neutron Interactions and Dosimetry", pp.463~505 (2004), WILEY-VCH Verlag GmbH & Co. KGaA

관련 논문AI추천

Measurement of the applicability of various experimental materials in a medically relevant reactor neutron source part two: Study of H3BO3 and B-DTPA under neutron irradiationHutli Ezddin, Zagyvai Peter한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제7호Conceptional design of an adjustable moderator for BNCT based on a neutron source of 2.8 MeV proton bombarding with Li targetDai Zhimin, Lin Zuokang, Yu Haiyan, Yu Xiaohan, Zhu Yinan한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제5호Design and analysis of an AB-BNCT self-shielding rotating neutron targetDai Ye, Dai Zhimin, Li Hao, Lin Zhiyuan, Lin Zuokang, Liu Yuchen, Ma Tianyu, Wu Guanchao, Zhang Zijian한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제9호Design of a PG-SPECT for boron concentration monitoring in BNCT at XJTUAtsushi Taketani, Dai Yuqi, Fan Jingjing, Han Zheng, Hu Yaocheng, Jiang Quanxu, Liu Kai, Liu Yongze, Wang Sheng, Yan Mingfei한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제7호Development and application analysis of high-energy neutron radiation shielding materials from tungsten boron polyethyleneBao Jie, Kuang Shaobao, Liu Songlin, Shao Qiankun, Wang Yuling, Zhu Qingjun한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제6호Recent research progress of BNCT treatment planning systemLi Jie, Li Zhifeng, Song Hongbing, Wang Baofeng, Wang Bo, Wang Sheng, Wang Zhaotong, Zheng Qi한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제3호

이 간행물의 다른 논문 (39건)