Application of peak based-Bayesian statistical method for isotope identification and categorization of depleted, natural and low enriched uranium measured by LaBr3:Ce scintillation detector
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Todays, medium energy resolution detectors are preferably used in radioisotope identification devices( RID) in nuclear and radioactive material categorization. However, there is still a need to develop or enhance « automated identifiers » for the useful RID algorithms. To decide whether any material is SNM or NORM, a key parameter is the better energy resolution of the detector. Although masking, shielding and gain shift/stabilization and other affecting parameters on site are also important for successful operations, the suitability of the RID algorithm is also a critical point to enhance the identification reliability while extracting the features from the spectral analysis. In this study, a RID algorithm based on Bayesian statistical method has been modified for medium energy resolution detectors and applied to the uranium gamma-ray spectra taken by a LaBr3:Ce detector. The present Bayesian RID algorithm covers up to 2000 keV energy range. It uses the peak centroids, the peak areas from the measured gamma-ray spectra. The extraction features are derived from the peak-based Bayesian classifiers to estimate a posterior probability for each isotope in the ANSI library. The program operations were tested under a MATLAB platform. The present peak based Bayesian RID algorithm was validated by using single isotopes(241Am, 57Co, 137Cs, 54Mn, 60Co), and then applied to five standard nuclear materials(0.32e4.51% at.235U), as well as natural U- and Th-ores. The ID performance of the RID algorithm was quantified in terms of F-score for each isotope. The posterior probability is calculated to be 54.5e74.4% for 238U and 4.7e10.5% for 235U in EC-NRM171 uranium materials. For the case of the more complex gamma-ray spectra from CRMs, the total scoring (ST) method was preferred for its ID performance evaluation. It was shown that the present peak based Bayesian RID algorithm can be applied to identify 235U and 238U isotopes in LEU or natural U eTh samples if a medium energy resolution detector is was in the measurements.
Abstract
Todays, medium energy resolution detectors are preferably used in radioisotope identification devices( RID) in nuclear and radioactive material categorization. However, there is still a need to develop or enhance « automated identifiers » for the useful RID algorithms. To decide whether any material is SNM or NORM, a key parameter is the better energy resolution of the detector. Although masking, shielding and gain shift/stabilization and other affecting parameters on site are also important for successful operations, the suitability of the RID algorithm is also a critical point to enhance the identification reliability while extracting the features from the spectral analysis. In this study, a RID algorithm based on Bayesian statistical method has been modified for medium energy resolution detectors and applied to the uranium gamma-ray spectra taken by a LaBr3:Ce detector. The present Bayesian RID algorithm covers up to 2000 keV energy range. It uses the peak centroids, the peak areas from the measured gamma-ray spectra. The extraction features are derived from the peak-based Bayesian classifiers to estimate a posterior probability for each isotope in the ANSI library. The program operations were tested under a MATLAB platform. The present peak based Bayesian RID algorithm was validated by using single isotopes(241Am, 57Co, 137Cs, 54Mn, 60Co), and then applied to five standard nuclear materials(0.32e4.51% at.235U), as well as natural U- and Th-ores. The ID performance of the RID algorithm was quantified in terms of F-score for each isotope. The posterior probability is calculated to be 54.5e74.4% for 238U and 4.7e10.5% for 235U in EC-NRM171 uranium materials. For the case of the more complex gamma-ray spectra from CRMs, the total scoring (ST) method was preferred for its ID performance evaluation. It was shown that the present peak based Bayesian RID algorithm can be applied to identify 235U and 238U isotopes in LEU or natural U eTh samples if a medium energy resolution detector is was in the measurements.
참고문헌 (24)
- Deborah K. Fagan, "Statistical methods applied to gamma-ray spectroscopy algorithms in nuclear security missions", Appl. Radiat. Isot, 70, pp.2428~2439 (2012)
- IAEA, "Combating Illicit Trafficking in Nuclear and Other Radioactive Material, Technical Guidance Reference Manual" (2007)
- C.J. Sullivan, "Evaluation of key detector parameters for isotope identification", 2007 IEEE Nuclear Science Symposium Conference Record, pp.1181~1184 (2007), IEEE
- C. J. Sullivan, "Validation of a Bayesian-based isotope identification algorithm", Nucl. Instrum. Methods Phys. Res. A, 784, pp.298~305 (2015)
- Evaluation of Handheld Isotope Identifiers, "J.M. Blackadar", ~, pp.LA-UR-03-2742 (2003)
- L. Pibida, "Evaluation of handheld radionuclide identifiers", J. Res. Nat. Inst. Stand. Technol, 109, pp.451~456 (2004)
- M. Swoboda, "Spectral gamma detectors for hand-held radioisotope identification devices (RIDs) for nuclear security applications", Nuclear Science Symposium Conference Record, 7, pp.4296~4302 (2004), IEEE
- ANSI, "ANS42.34, American National Standard Performance Criteria for Hand-Held Instruments for the Detection and Identification of Radionuclides, 2006", ~ (2006)
- J. B. Stinnet, "Bayesian Algorithms for Automated Isotope Identification", Ph.D., pp.2014
- J. Stinnett, "An automated isotope identification algorithm using Bayesian statistics", 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS, 2013, ~[DOI]
- Genie 2000TM Canberra Inc, "Genie 2000 Gamma Software User Manual", ~
- "Canadian Certified Reference Materials Project of Natural Resources Canada (NRCan)" (2022)[URL]
- EC Nuclear Reference Material 171 Certification Report(EUR 10503 EN) -235 Uranium Isotope Abundance Certified Reference Material for Gamma Spectrometry, "P. de Bievre", Commission of The European Communities , Directorate-General Information Market and Innovation, B^atiment Jean Monnet, ~ (1986)
- Tom Burr, "Radio-Isotope Identification Algorithms for NaI γ Spectra", Algorithms, 2(1), pp.339~360 (2009), MDPI AG[DOI]
- C. Bobin, "Applied Radiation and Isotopes: Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine" (2015)
- Tom Burr, "Application of the Approximate Bayesian Computation Algorithm to Gamma-Ray Spectroscopy", Algorithms, 13(10), pp.265~ (2020), MDPI AG[DOI]
- G. Gilmore, "Practical Gamma-Ray Spectrometry" (2008), John Wiley &Sons
- M. Goldstein, "Bayes Linear Statistics Theory and Methods" (2007), John Wiley & Sons
- B. P. Carlin, "Bayes and Empirical Bayes Methods for Data Analysis" (2000), CRC Press Company
- J.B. Stinnet, "Automated Isotope Identification Algorithms for Low-Resolution Detectors", pp.2016
- Radioisotope Identification System (RadIS) Performance Assessment Results, "DRDC", Ottawa Research Centre, ~, pp.Scientific Report (2016)
- Algorithm Improvement Program Nuclide Identification Algorithm Scoring Criteria and Scoring Application, "DNDO", Domestic Nuclear Detection Office, ~, pp.SAND2015-0743R (2015)
- O. Ekici, "_Istatistikte bayesyen ve klasik yaklas¸ ımın kavramsal farklılıkları (in Turkish)", Balıkesir Üniversitesi Sosyal Bilimler Enstitüsü Dergisi, 12(21), pp.89~101 (2009)
- "Algorithm Improvement Program" (2016)[URL]