본문 바로가기
KERD
논문KCI 등재

Realistic thermal analysis of the CANDU spent fuel dry storage canister

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Thermal analysis of the CANDU spent fuel dry storage canister is very important to ensure the integrity of the spent fuel. The analyses have been conducted using a conservative approach, with a particular focus on the peak cladding temperature (PCT) of the fuel rods in the canister. In this study, we have performed a realistic thermal analysis using a computational fluid dynamics (CFD) code. The canister contains 9 fuel bundle baskets. A detailed analysis of even a single basket requires significant computational resources. To overcome this challenge, we replaced each basket with an equivalent heat conductor (EHC), of which effective thermal conductivity (ETC) is developed from the results of detailed CFD calculations of a fuel bundle basket. Then, we investigated the effects of some conservative models, ultimately aiming at a realistic analysis. The results revealed: (i) The influence of convective heat transfer in the basket cannot be ignored, but it’s less significant than expected. (ii) Modeling of the lifting rod is crucial, as it plays a decisive role in axial heat transfer at the center of the canister and significantly reduces the PCT. (iii) Convection within the canister is very important, as it not only reduces the PCT but also shifts its location upwards.

Abstract

Thermal analysis of the CANDU spent fuel dry storage canister is very important to ensure the integrity of the spent fuel. The analyses have been conducted using a conservative approach, with a particular focus on the peak cladding temperature (PCT) of the fuel rods in the canister. In this study, we have performed a realistic thermal analysis using a computational fluid dynamics (CFD) code. The canister contains 9 fuel bundle baskets. A detailed analysis of even a single basket requires significant computational resources. To overcome this challenge, we replaced each basket with an equivalent heat conductor (EHC), of which effective thermal conductivity (ETC) is developed from the results of detailed CFD calculations of a fuel bundle basket. Then, we investigated the effects of some conservative models, ultimately aiming at a realistic analysis. The results revealed: (i) The influence of convective heat transfer in the basket cannot be ignored, but it’s less significant than expected. (ii) Modeling of the lifting rod is crucial, as it plays a decisive role in axial heat transfer at the center of the canister and significantly reduces the PCT. (iii) Convection within the canister is very important, as it not only reduces the PCT but also shifts its location upwards.

참고문헌 (18)

  1. Safety analysis report for spent fuel dry storage Wolsong nuclear power, Plant Unit 1, "KEPCO", ~ (1990)
  2. Safety Analysis Report for Wolsong Unit 1 Spent Nuclear Fuel Dry Storage Facilities, "Khnp", Korea Hydro & Nuclear Power, ~ (2004)
  3. K. H. Lee, "Evaluation of Maximum Allowable Temperature inside Basket of Dry Storage Module for CANDU Spent Fuel", Proc. Korean Nuclear Society Autumn Meeting (2002)
  4. Standard Review Plan for Spent Fuel Dry Storage Systems and Facilities, "USNRC", NUREG, 2215~ (2017)
  5. Maximum Allowable Fuel Temperature in MACSTOR, "KN-400 Storage Module", R. Beaydoin, 2004, MKN4-25000-220-001, Rev. 1
  6. 국동학, "Review of Spent Fuel Integrity Evaluation for Dry Storage", Nuclear Engineering and Technology, 45(1), pp.115~124 (2013), 한국원자력학회
  7. Storage Basket Heat Transfer Assessment of the MACSTOR, "KN-400 Storage Module", AECL, 2002, MKN4-25000-220-003 Revision D0
  8. M. H. Chun, "A simplified two-step thermal analysis method for wolsung (CANDU) spent fuel dry storage canister", Int. Commun. Heat Mass Tran, 20, pp.185~196 (1993)
  9. Spent nuclear fuel effective thermal conductivity report, in: Civilian Radioactive Waste Management System Management and Operating Contractor, "TRW Environmental Safety Systems Inc", ~, pp.BBA000000-01717-5705-00010Rev. 0 (1996)
  10. ANSYS Southpointe, "ANSYS Fluent Theory Guide", ANSYS lnc, ~ (2021)
  11. ANSYS Southpointe, "ANSYS Fluent User’s Guide", ANSYS lnc, ~ (2021)
  12. ANSYS Southpointe, "Discovering SpaceClaim", ANSYS lnc, ~ (2021)
  13. ANSYS Southpointe, "ANSYS Meshing User’s Guide", ANSYS lnc., ~ (2021)
  14. D. G. Lee, "An assessment of temperature history on concrete silo dry storage system for CANDU spent fuel", Ann. Nucl. Energy, 94, pp.263~271 (2016)
  15. Computational Fluid Dynamics Best Practice Guidelines for Dry Cask Applications, "G. Zigh", U.S. Nuclear Regulatory Commission, ~, pp.NUREG-2152 (2013)
  16. H.Y. Nam, "Experimental Study on the Emissivity of Stainless Steel", Proceedings of the Korean Nuclear Society Spring Meeting (2001)
  17. F.P. Incropera, "Principles of Heat and Mass Transfer", pp.538~551 (2017), Wiley
  18. T. G. Lee, "Thermal Analysis of the CANDU Spent Fuel Storage Canister", Proc, Korean Nuclear Society Autumn Meeting (2022)