본문 바로가기
KERD
논문KCI 등재

Feasibility of a position-sensitive Cherenkov radiation detector using a reflector-coated liquid light guide

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

In this study, a Cherenkov radiation sensor was developed utilizing a reflector-coated liquid light guide (LLG). In the proposed configuration, a reflector replaced one of the two photomultiplier tubes (PMTs), forming the core sensing element alongside the LLG, with gamma-ray (60Co and 137Cs) and a beta-ray (90Sr) emitters employed to assess its performance as a position-sensitive detector. The time-of-flight method was utilized to determine time differences corresponding to source positions. Position spectra were generated based on these time differences, with the Cherenkov radiation count rates compared across different types of reflectors to identify the optimal choice. We compared position spectra obtained from two PMTs and one PMT with a reflector, confirming the ability to detect multiple sources. Subsequently, each source was positioned perpendicular or parallel to the sensor axis to capture position spectra. The results demonstrate the sensor’s potential as a long-distance positionsensitive detector. By leveraging the simplicity of a single PMT system, the proposed sensor facilitates challenging tasks such as pipeline inspection or non-destructive testing of radioactive waste drums.

Abstract

In this study, a Cherenkov radiation sensor was developed utilizing a reflector-coated liquid light guide (LLG). In the proposed configuration, a reflector replaced one of the two photomultiplier tubes (PMTs), forming the core sensing element alongside the LLG, with gamma-ray (60Co and 137Cs) and a beta-ray (90Sr) emitters employed to assess its performance as a position-sensitive detector. The time-of-flight method was utilized to determine time differences corresponding to source positions. Position spectra were generated based on these time differences, with the Cherenkov radiation count rates compared across different types of reflectors to identify the optimal choice. We compared position spectra obtained from two PMTs and one PMT with a reflector, confirming the ability to detect multiple sources. Subsequently, each source was positioned perpendicular or parallel to the sensor axis to capture position spectra. The results demonstrate the sensor’s potential as a long-distance positionsensitive detector. By leveraging the simplicity of a single PMT system, the proposed sensor facilitates challenging tasks such as pipeline inspection or non-destructive testing of radioactive waste drums.

참고문헌 (33)

  1. H. G. Byun, "Development of safety assessment code for decommissioning waste recycling and disposal", Radiat. Protect. Dosim, 199, pp.191~208 (2023)[DOI]
  2. Nuclear Power Reactors in the World, "IAEA", International Atomic Energy Agency, ~, pp.Reference Data Series No. 2 (2023)
  3. S. Hong, "Decontamination of neutron-activated radioactive concrete waste by separating Eu, Co, Fe, and Mn-containing sand particles using dense medium separation", J. Hazard Mater, 443, pp.130183~ (2023)[DOI]
  4. Managing Low Radioactivity Material from the Decommissioning of Nuclear Facilities, vol. 462, "IAEA", International Atomic Energy Agency, ~ (2008)
  5. Inventory of Materials with Very Low Levels of Radioactivity Potentially Clearable from Various Types of Facilities, "NRC", United States Nuclear Regulatory Commission, ~ (2001)
  6. The Future of the Nuclear Fuel Cycle, "MITEI", Massachusetts Institute of Technology, ~ (2011)
  7. D. G. Davis, "Uptake of cesium ions by human erythrocytes and perfused rat heart : a cesium-133 NMR study", Biochemistry, 27, pp.3547~3551 (1988)[DOI]
  8. "Radiation protection:radionuclide Basics: strontium-90"[URL]
  9. Determination and Use of Scaling Factors for Waste Characterization in Nuclear Power Plants, "IAEA", International Atomic Energy Agency, ~ (2009)
  10. H. Gamo, "Development of a PSF-detector for contaminated areas", Prog. Nucl. Sci. And Technol, 4, pp.695~698 (2014)[DOI]
  11. P. Finocchiaro, "Radioactive Waste: Sources, Types and Management" (2012), Nova Science Pub Inc.
  12. S. Song, "High-spatialresolution position-sensitive plastic scintillation optical fiber bundle detector", Photon, 8, pp.26~37 (2021)[DOI]
  13. L. Gruber, "LHCb SciFi — upgrading LHCb with a scintillating fibre tracker", Nucl. Instrum. Methods Phys. Res., Sect. A, 958, pp.168~ (2020)[DOI]
  14. T. Kirn, "SciFi – a large scintillating fibre tracker for LHCb", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 845, pp.481~485 (2017)[DOI]
  15. D. Lee, "Colored reflectors to improve coincidence timing resolution of BGO-based time-of-flight PET detectors", Phys. Med. Biol, 68, pp.185008~ (2023)[DOI]
  16. G. F. Knoll, "Radiation Detection and Measurement" (2000), John Wiley & Sons, Inc.
  17. I. M. Frank, "On some peculiarities of Vavilov-Cherenkov radiation", Nucl. Instrum. Methods Phys. Res., Sect. A, 248, pp.7~12 (1986)[DOI]
  18. K. W. Jang, "Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry", J. Biomed. Opt, 18, pp.27001~ (2013)[DOI]
  19. Y. Terasaka, "Evaluation of a one-dimensional positionsensitive quartz optical fiber sensor based on the time-of-flight method for high radiation dose rate applications", Nucl. Instrum. Methods Phys. Res., Sect. A, 996, pp.165151~ (2021)[DOI]
  20. J. Kawarabayashi, "Potential on liquid light guide as distributed radiation sensor 2", 712~714 (2004)
  21. M. Hayashi, "Positionsensitive radiation detector with flexible light guide and liquid organic scintillator to monitor distributions of radioactive isotopes", J. Nucl. Sci. Technol, (45 sup6), pp.81~84 (2008)[DOI]
  22. K. Nomura, "Development of a flexible γ-ray detector using a liquid scintillation light guide(LSLG)", Appl. Radiat. Isot, 139, pp.12~19 (2018)[DOI]
  23. "Siglent, SDS5104X oscilloscope datasheet"[URL]
  24. W.R. Leo, "Techniques for Nuclear and Particle Physics Experiments: a How-To Approach" (2012), Springer Science & Business Media
  25. W. XiangLei, "Development of high-resolution time pick-off detector based on micro-channel Plate", Nucl. Instrum. Methods Phys. Res., Sect. A, 1055, pp.168~ (2023)[DOI]
  26. J. V. Jelley, "Photochemical and Photobiological Reviews" (1983), Springer
  27. "Hamamatsu, H10721-01P datasheet"[URL]
  28. "Lumatec, Liquid light guide datasheet"[URL]
  29. H. Backer, "Coincident detection of Cherenkov photons from Compton scattered electrons for medical applications", Nucl. Instrum. Methods Phys. Res., Sect. A, 958, pp.162797~ (2020)[DOI]
  30. E. Lorincz, "Modeling and optimization of scintillator arrays for PET detectors", IEEE Trans. Nucl. Sci, 57, pp.48~54 (2010)[DOI]
  31. "Thorlabs, PMR10P1 film datasheet"[URL]
  32. "Saint-Gobain, BC-620 paint datasheet"[URL]
  33. Y. Terasaka, "A new application technique of a position-sensitive liquid light guide Cerenkov counter for the simultaneous position detection of 90Sr", 90Y and 137Cs radioactivity, 2023, pp.1049, 168~

관련 논문AI추천