초록

Considering the importance of having a suitable dosimeter to measure the dose in the range of 10–1000 Gy, the dosimetry response of calcium phosphate, as a thermoluminescent dosimeter, was investigated. In addition to studying the dosimetric response of the samples in powder shapes, the tablet forms of the samples produced by compressing the powders with the spark plasma sintering method at 650 ◦C and 685 ◦C and 40 MPa were also examined. The findings indicate that most samples exhibit a linear response within the desired dose range and have a good response to dose changes. The average glow peak temperature ranged from 195 to 235 ◦C. The weakness of the samples was their fading effects; thus, most samples lost their effectiveness within 30 days. While the results indicate that the synthesized β-TCP calcium phosphate tablets compressed at 650 ◦C and 40 MPa show the best dose response among the samples studied, a comparison between the dosimetric responses of powder and tablet forms reveals that the tablet preparation conditions are crucial, and converting powder into tablets does not necessarily yield improved dosimetric outcomes.

Abstract

Considering the importance of having a suitable dosimeter to measure the dose in the range of 10–1000 Gy, the dosimetry response of calcium phosphate, as a thermoluminescent dosimeter, was investigated. In addition to studying the dosimetric response of the samples in powder shapes, the tablet forms of the samples produced by compressing the powders with the spark plasma sintering method at 650 ◦C and 685 ◦C and 40 MPa were also examined. The findings indicate that most samples exhibit a linear response within the desired dose range and have a good response to dose changes. The average glow peak temperature ranged from 195 to 235 ◦C. The weakness of the samples was their fading effects; thus, most samples lost their effectiveness within 30 days. While the results indicate that the synthesized β-TCP calcium phosphate tablets compressed at 650 ◦C and 40 MPa show the best dose response among the samples studied, a comparison between the dosimetric responses of powder and tablet forms reveals that the tablet preparation conditions are crucial, and converting powder into tablets does not necessarily yield improved dosimetric outcomes.

관련 논문AI추천

Optimized LiZnBO3 phosphor as a promising candidate for low dose radiation dosimetryAl-Mamun Md, Hasnat Md Abul, Hassan Md Nazmul, Hossain Shahadat, Islam Shah Azharul, Kamruzzaman Md, Khandaker Mayeen Uddin, Mahmoud Mustafa, Mimi Homaira Afia, Osman Hamid, Rahat Md Raghib, Rahman A.K.M. Mizanur한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제6호Dosimetric properties of Mg-doped Al2O3 transparent ceramicsNoriaki Kawaguchi, Takayuki Yanagida, Takumi Kato청정에너지연구소 · Journal of Ceramic Processing Research2019 · 제20권 제5호Generation of LiF(Mg,Cu,Na,Si) thermoluminescent crystal and evaluation of dose response and sensitivityKhorshidi Abdollah한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제7호Thermoluminescence response of carbon ion beam irradiated LiCaAlF6: Tb phosphorAggarwal Shruti, Jain Aayushi, Seth Pooja한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제11호Thermoluminescence study of electron-irradiated LiZnBO3 phosphor for dosimetry applicationAl-Mamun Md, Hassan Md Nazmul, Hossain Shahadat, Kamruzzaman Md, Khandaker Mayeen Uddin, Mizanur Rahman A.K.M., Muslima Umme, Rahat Md Raghib한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제12호Thermoluminescence characterization of biochar material for dosimetric applicationsBradley D.A., Khandaker Mayeen Uddin, Lam S.E., Mahmoud Mustafa, Muslima Umme, Nawi S.N. Mat, Sani S.F. Abdul, Woo H.J.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호

이 간행물의 다른 논문 (59건)