본문 바로가기
KERD
논문KCI 등재

염소이온 함유된 용액에서 Ti합금의 부식특성에 미치는 Hafnium함량의 영향

Effects of Hafnium Addition on the Pitting Corrosion Behavior of Ti Alloys in Electrolyte Containing Chloride Ion

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류금속공학

초록

The aim of this study was to investigate effects of hafnium content on the corrosion behavior of Ti alloys in electrolyte containing chloride ion. For this study, Ti-Hf binary alloys contained 10 wt%, 20 wt% and 30 wt%Hf were manufactured in a vacuum arc-melting furnace and subjected to heat treatment for 12h at 1000°C in an argon atmosphere. The pitting corrosion behavior of the specimens was examined through potentiodynamic and potentiostatic tests in 0.9 wt% NaCl electrolyte at 36.5 ± 1°C. The corrosion morphology of Ti-xHf alloys was investigated using optical microscopy (OM) and X-ray diffractometer (XRD). From the optical microstructures and XRD results, needle-like martensite (α') phases of the Ti-xHf alloys increased with an increase of Hf addition. Corrosion current density (Icorr) and current density (I300mV) in passive region decreased, whereas, corrosion potential increased with Hf content. At the constant potential (300 mVSCE), current density decreased as time increased.

Abstract

The aim of this study was to investigate effects of hafnium content on the corrosion behavior of Ti alloys in electrolyte containing chloride ion. For this study, Ti-Hf binary alloys contained 10 wt%, 20 wt% and 30 wt%Hf were manufactured in a vacuum arc-melting furnace and subjected to heat treatment for 12h at 1000°C in an argon atmosphere. The pitting corrosion behavior of the specimens was examined through potentiodynamic and potentiostatic tests in 0.9 wt% NaCl electrolyte at 36.5 ± 1°C. The corrosion morphology of Ti-xHf alloys was investigated using optical microscopy (OM) and X-ray diffractometer (XRD). From the optical microstructures and XRD results, needle-like martensite (α') phases of the Ti-xHf alloys increased with an increase of Hf addition. Corrosion current density (Icorr) and current density (I300mV) in passive region decreased, whereas, corrosion potential increased with Hf content. At the constant potential (300 mVSCE), current density decreased as time increased.

참고문헌 (17)

  1. S. Rao, , J. Biomed. Mater. Eng, 6, pp.79~ (1996)
  2. G. C. McKay, , Biomaterials, 17, pp.1339~ (1996)
  3. N. R. Van, , J. Mater. Sci, 22, pp.3801~ (1987)
  4. M. F. Semlitsch, , Biomaterials, 13, pp.781~ (1992)
  5. Y. Okazaki, , J. Japan Inst. Metals, 9, pp.890~ (1996)
  6. M. Niinomi, , Metall Mater. Trans, 33, pp.477~ (2002)
  7. Z. Cai, , Acta Biomater, 1, pp.353~ (2005)
  8. E. W. Collings, "Physical Metallurgy of Titanium Alloys" (1984), ASM
  9. R. Strietzel, , Biomaterials, 19, pp.1495~ (1998)
  10. P. A. Dearnly, , Wear, 256, pp.469~ (2003)
  11. D. Velten, , J. Biomed. Mater. Res, 59, pp.18~ (2002)
  12. Y. H. Jeong, , Thin Solid Film, 517, pp.5365~ (2009)
  13. Y. L. Zhou, , Surf. Coat. Tech, 204, pp.180~ (2009)
  14. H. C. Choe, , Thin Solid Films, 519, pp.4652~ (2011)
  15. Y. H. Jeong, , Trans. Nonferr. Metals. Soc. China, 19, pp.852~ (2009)
  16. B. L. Wang, , Materials and Corrosion, 60, pp.330~ (2009)
  17. Y. H. jeong, , Surf. Coat. Tech (2012)

관련 논문AI추천

이 간행물의 다른 논문 (7건)