Rotating cylinder를 이용한 탄소강의 유동가속부식 평가

Evaluation of Flow Accelerated Corrosion of Carbon Steel with Rotating Cylinder

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류금속공학

초록

Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. Rotating cylinder FAC test facility was designed and fabricated and then performance of the facility was evaluated. The facility is very simple in design and economic in fabrication and can be used in material and chemistry screening test. The facility is equipped with on line monitoring of pH, conductivity,dissolved oxygen(DO), and temperature. Fluid velocity is controlled with rotating speed of the cylinder with a test specimen. FAC test of SA106 Gr. B carbon steel under 4 m/s flow velocity was performed with the rotating cylinder at DO concentration of less than 1 ppb and of 1.3 ppm. Also a corrosion test of the carbon steel at static condition, that is at zero fluid velocity, of test specimen and solution was performed at pH from 8 to 10 for comparison with the FAC data. For corrosion test in static condition, the amount of non adherent corrosion product was almost constant at pH ranging from 8 to 10. But adherent corrosion product decreased with increasing pH. This trend is consistent with decrease of Fe solubility with an increase in pH. For FAC test with rotating cylinder FAC test facility, the amount of non adherent corrosion product was also almost same for both DO concentrations. The rotating cylinder FAC test facility will be further improved by redesigning rotating cylinder and FAC specimen geometry for future work.

Abstract

Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. Rotating cylinder FAC test facility was designed and fabricated and then performance of the facility was evaluated. The facility is very simple in design and economic in fabrication and can be used in material and chemistry screening test. The facility is equipped with on line monitoring of pH, conductivity,dissolved oxygen(DO), and temperature. Fluid velocity is controlled with rotating speed of the cylinder with a test specimen. FAC test of SA106 Gr. B carbon steel under 4 m/s flow velocity was performed with the rotating cylinder at DO concentration of less than 1 ppb and of 1.3 ppm. Also a corrosion test of the carbon steel at static condition, that is at zero fluid velocity, of test specimen and solution was performed at pH from 8 to 10 for comparison with the FAC data. For corrosion test in static condition, the amount of non adherent corrosion product was almost constant at pH ranging from 8 to 10. But adherent corrosion product decreased with increasing pH. This trend is consistent with decrease of Fe solubility with an increase in pH. For FAC test with rotating cylinder FAC test facility, the amount of non adherent corrosion product was also almost same for both DO concentrations. The rotating cylinder FAC test facility will be further improved by redesigning rotating cylinder and FAC specimen geometry for future work.

참고문헌 (8)

  1. J. H. Han, , J. of Korean Nuclear Soc, 26, pp.312~ (1994)
  2. T. Satoh, , Corrosion, 63, pp.770~ (2007)
  3. K. S. Kang, , Korea Atom Ind Forum, 24, pp.4~ (2004)
  4. JEONG HO MOON, "DEPENDENCY OF SINGLE-PHASE FAC OF CARBON AND LOW-ALLOY STEELS FOR NPP SYSTEM PIPING ON PH,ORIFICE DISTANCE AND MATERIAL", Nuclear Engineering and Technology, 37(4), pp.375~384 (2005), 한국원자력학회
  5. S. H. Kim, , J. Korean Radioactive Waste Soc, 3, pp.31~ (2005)
  6. N. Y. Lee, , Nucl. Eng. Des, 237, pp.761~ (2007)
  7. K. H. Ryu, , Nucl. Eng. Des, 240, pp.468~ (2010)
  8. P. J. King, , 11th Int. Conf. Environmental Degradation of Materials in Nuclear Systems, pp.717~ (2003)