The influence of suture materials on the biomechanical behavior of suture-meniscal specimens: a comparative study in a porcine model
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background: Repair of a meniscal tear is indicated in certain conditions. Despite extensive research on the biomechanics of various repair methods, there has been minimal investigation of whether the suture material influences the meniscal-suture construct. The purpose of this study was to compare the biomechanical properties of nine different suture materials under cyclic and load-to-failure conditions. Methods: Ninety porcine menisci were randomly allocated to simple suture placement using either Ultrabraid®, Ultratape®, Magnum Wire®, TigerWire®, TigerTape®, LabralTape®, Orthocord®, 0 FiberWire®, or 2-0 FiberWire®. Each suture-meniscus specimen underwent cyclic loading followed by load-to-failure testing. Elongation, maximum load to failure, stiffness, and mode of failure were recorded and compared between each suture type using nonparametric testing. Mean ± standard deviation was reported and the statistical significance was p < 0.05. Results: Elongation during cyclic loading was lowest with 2-0 FiberWire (0.95 ± 0.17 mm); this value was statistically significantly different than the results for all other sutures except 0 FiberWire® (1.09 ± 0.17 mm, p = 0.79), TigerWire® (1.09 ± 0.29 mm, p = 0.85), TigerTape® (1.39 ± 0.29 mm, p = 0.08), and LabralTape® (1.20 ± 0.33 mm, p = 0.41). The highest elongation was seen with Ultrabraid® (1.91 ± 0.34 mm); this value was statistically significantly greater than the results for all other suture materials except Orthocord® (1.59 mm ± 0.31 mm, p = 0.46) and Magnum Wire® (1.43 ± 0.25 mm, p = 0.14). Load to failure was highest for TigerTape® (287.43 ± 41.15 N), and this result was statistically significantly different than the results for all other sutures except LabralTape® (271.34 ± 48.48 N, p = 0.99) and TigerWire® (251.03 ± 25.8 N, p = 0.51). Stiffness was highest for LabralTape® (195.77 ± 49.06 N/mm), and this result was statistically significantly different than the results for all other sutures except TigerWire® (186.49 ± 19.83 N/ mm, p = 0.45) and TigerTape® (173.35 ± 15.60 N/mm, p = 0.19). The majority of sutures failed by pullout (n = 46, 51%) or tearing (n = 40, 45%). Conclusion: Suture design and material affect the biomechanical behavior of porcine meniscal-suture specimens. LabralTape®, TigerWire®, and TigerTape® demonstrated better overall combinations of low elongation, high maximum load to failure, and high stiffness.
Abstract
Background: Repair of a meniscal tear is indicated in certain conditions. Despite extensive research on the biomechanics of various repair methods, there has been minimal investigation of whether the suture material influences the meniscal-suture construct. The purpose of this study was to compare the biomechanical properties of nine different suture materials under cyclic and load-to-failure conditions. Methods: Ninety porcine menisci were randomly allocated to simple suture placement using either Ultrabraid®, Ultratape®, Magnum Wire®, TigerWire®, TigerTape®, LabralTape®, Orthocord®, 0 FiberWire®, or 2-0 FiberWire®. Each suture-meniscus specimen underwent cyclic loading followed by load-to-failure testing. Elongation, maximum load to failure, stiffness, and mode of failure were recorded and compared between each suture type using nonparametric testing. Mean ± standard deviation was reported and the statistical significance was p < 0.05. Results: Elongation during cyclic loading was lowest with 2-0 FiberWire (0.95 ± 0.17 mm); this value was statistically significantly different than the results for all other sutures except 0 FiberWire® (1.09 ± 0.17 mm, p = 0.79), TigerWire® (1.09 ± 0.29 mm, p = 0.85), TigerTape® (1.39 ± 0.29 mm, p = 0.08), and LabralTape® (1.20 ± 0.33 mm, p = 0.41). The highest elongation was seen with Ultrabraid® (1.91 ± 0.34 mm); this value was statistically significantly greater than the results for all other suture materials except Orthocord® (1.59 mm ± 0.31 mm, p = 0.46) and Magnum Wire® (1.43 ± 0.25 mm, p = 0.14). Load to failure was highest for TigerTape® (287.43 ± 41.15 N), and this result was statistically significantly different than the results for all other sutures except LabralTape® (271.34 ± 48.48 N, p = 0.99) and TigerWire® (251.03 ± 25.8 N, p = 0.51). Stiffness was highest for LabralTape® (195.77 ± 49.06 N/mm), and this result was statistically significantly different than the results for all other sutures except TigerWire® (186.49 ± 19.83 N/ mm, p = 0.45) and TigerTape® (173.35 ± 15.60 N/mm, p = 0.19). The majority of sutures failed by pullout (n = 46, 51%) or tearing (n = 40, 45%). Conclusion: Suture design and material affect the biomechanical behavior of porcine meniscal-suture specimens. LabralTape®, TigerWire®, and TigerTape® demonstrated better overall combinations of low elongation, high maximum load to failure, and high stiffness.
참고문헌 (40)
- Hede A, "Epidemiology of meniscal lesions in the knee. 1,215 open operations in Copenhagen 1982-84", Acta Orthop Scand, 61(5), pp.435~437 (1990)
- Choi SH, "The MRI findings of meniscal root tear of the medial meniscus : emphasis on coronal, sagittal and axial images", Knee Surg Sports Traumatol Arthrosc, 20, pp.2098~2103 (2012)
- Han SB, "Unfavorable results of partial meniscectomy for complete posterior medial meniscus root tear with early osteoarthritis : a 5-to 8-year follow-up study", Arthroscopy, 26, pp.1326~1332 (2010)
- Robertson DD, "Meniscal root injury and spontaneous osteonecrosis of the knee : an observation", J Bone Joint Surg(Br), 91, pp.190~195 (2009)
- Sung JH, "Meniscal extrusion and spontaneous osteonecrosis with root tear of medial meniscus : comparison with horizontal tear", Arthroscopy, 29, pp.726~732 (2013)
- Allaire R, "Biomechanical consequences of a tear of the posterior root of the medial meniscus", Similar to total meniscectomy. J Bone Joint Surg Am, 90, pp.1922~1931 (2008)
- Forkel P, "Biomechanical consequences of a posterior root tear of the lateral meniscus : stabilizing effect of the meniscofemoral ligament", Arch Orthop Trauma Surg, 133, pp.621~626 (2013)
- Kim JG, "Tibiofemoral contact mechanics following posterior root of medial meniscus tear, repair, meniscectomy, and allograft transplantation", Knee Surg Sports Traumatol Arthrosc, 21, pp.2121~2125 (2013)
- Marzo JM, "Effects of medial meniscus posterior horn avulsion and repair on tibiofemoral contact area and peak contact pressure with clinical implications", Am J Sports Med, 37, pp.124~129 (2009)
- Schillhammer CK, "Repair of lateral meniscus posterior horn detachment lesions : a biomechanical evaluation", Am J Sports Med, 40, pp.2604~2609 (2012)
- Ahn JH, "Double transosseous pull out suture technique for transection of posterior horn of medial meniscus", Arch Orthop Trauma Surg, 129, pp.387~392 (2009)
- Ahn JH, "A pull out suture for transection of the posterior horn of the medial meniscus: using a posterior trans-septal portal", Knee Surg Sports Traumatol Arthrosc, 15, pp.1510~1513 (2007)
- Forkel P, "Posterior root tear fixation of the lateral meniscus combined with arthroscopic ACL double-bundle reconstruction:technical note of a transosseous fixation using the tibial PL tunnel", Arch Orthop Trauma Surg, 132, pp.387~391 (2012)
- Harner CD, "Biomechanical consequences of a tear of the posterior root of the medial meniscus. Surgical technique", J Bone Joint Surg Am, 91(Suppl 2), pp.257~270 (2009)
- Moon HK, "Prognostic factors of arthroscopic pull-out repair for a posterior root tear of the medial meniscus", Am J Sports Med, 40, pp.1138~1143 (2012)
- Feucht MJ, "Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears", Knee Surg Sports Traumatol Arthrosc, 23, pp.132~139 (2015)
- Kim YM, "Pullout failure strength of the posterior horn of the medial meniscus with root ligament tear", Knee Surg Sports Traumatol Arthrosc, 21, pp.1546~1552 (2013)
- Kopf S, "Meniscal root suturing techniques : implications for root fixation", Am J Sports Med, 39, pp.2141~2146 (2011)
- Rosslenbroich SB, "Root tear of the meniscus : biomechanical evaluation of an arthroscopic refixation technique", Arch Orthop Trauma Surg, 133, pp.111~115 (2013)
- Bisson LJ, "A biomechanical comparison of the pullout strength of No. 2 FiberWire suture and 2-mm FiberWire tape in bovine rotator cuff tendons", Arthroscopy, 26, pp.1463~1468 (2010)
- Bisson LJ, "Influence of suture material on the biomechanical behavior of suture-tendon specimens : a controlled study in bovine rotator cuff", Am J Sports Med, 36, pp.907~912 (2008)
- Herbort M, "Strategies for repair of radial tears close to the meniscal rim—biomechanical analysis with a cyclic loading protocol", Am J Sports Med, 38, pp.2281~2287 (2010)
- Jaspers P, "The mechanical function of the meniscus, experiments on cadaveric pig knee-joints", Acta Orthop Belg, 46, pp.663~668 (1980)
- Lee YH, "Cyclic test comparison of allinside device and inside-out sutures for radial meniscus lesion repair : an in vitro porcine model study", Arthroscopy, 28, pp.1873~1881 (2012)
- Post WR, "Load to failure of common meniscal repair techniques : effects of suture technique and suture material", Arthroscopy, 13, pp.731~736 (1997)
- Zantop T, "Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios : biomechanical evaluation using a cyclic loading protocol", Am J Sports Med, 34, pp.799~805 (2006)
- Zantop T, "Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors : biomechanical evaluation of new meniscus refixation systems", Am J Sports Med, 32, pp.863~869 (2004)
- Zantop T, "Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bonepatellar tendon-bone grafts", Arthroscopy, 21, pp.934~941 (2005)
- Ma CB, "Biomechanical evaluation of arthroscopic rotator cuff repairs : double-row compared with single-row fixation", J Bone Joint Surg Am, 88, pp.403~410 (2006)
- Ma CB, "Biomechanical evaluation of arthroscopic rotator cuff stitches", J Bone Joint Surg Am, 86-A, pp.1211~1216 (2004)
- Stringtheory: an examination of the properties of “high strength” suture materials, "Jhamb A", University of New South Wales, Prince of Wales Hospital, ~ (2007)
- "DePuy Synthes Mitek Sports Medicine. Orthocord™ Product Information" (2015)[URL]
- Stärke C, "The effect of a nonanatomic repair of the meniscal horn attachment on meniscal tension : a biomechanical study", Arthroscopy, 26, pp.358~365 (2010)
- Lerer DB, "The role of meniscal root pathology and radial meniscal tear in medial meniscal extrusion", Skelet Radiol, 33, pp.569~574 (2004)
- Stärke C, "Tensile forces at the porcine anterior meniscal horn attachment", J Orthop Res, 27, pp.1619~1624 (2009)
- Burkhart SS, "Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure must the knot be?", Arthroscopy, 16, pp.202~207 (2000)
- Burkhart SS, "Loop security as a determinant of tissue fixation security", Arthroscopy, 14, pp.773~776 (1998)
- Wüst DM, "Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures", Arthroscopy, 22, pp.1146~1153 (2006)
- Lee YH, "Repair of peripheral vertical meniscus lesions in porcine menisci : in vitro biomechanical testing of 3different meniscus repair devices", Am J Sports Med, 41, pp.1074~1081 (2013)
- Aşík M, "Failure strength of repair devices versus meniscus suturing techniques", Knee Surg Sports Traumatol Arthrosc, 10, pp.25~29 (2002)