본문 바로가기
KERD
논문KCI 등재

The influence of suture materials on the biomechanical behavior of suture-meniscal specimens: a comparative study in a porcine model

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Background: Repair of a meniscal tear is indicated in certain conditions. Despite extensive research on the biomechanics of various repair methods, there has been minimal investigation of whether the suture material influences the meniscal-suture construct. The purpose of this study was to compare the biomechanical properties of nine different suture materials under cyclic and load-to-failure conditions. Methods: Ninety porcine menisci were randomly allocated to simple suture placement using either Ultrabraid®, Ultratape®, Magnum Wire®, TigerWire®, TigerTape®, LabralTape®, Orthocord®, 0 FiberWire®, or 2-0 FiberWire®. Each suture-meniscus specimen underwent cyclic loading followed by load-to-failure testing. Elongation, maximum load to failure, stiffness, and mode of failure were recorded and compared between each suture type using nonparametric testing. Mean ± standard deviation was reported and the statistical significance was p < 0.05. Results: Elongation during cyclic loading was lowest with 2-0 FiberWire (0.95 ± 0.17 mm); this value was statistically significantly different than the results for all other sutures except 0 FiberWire® (1.09 ± 0.17 mm, p = 0.79), TigerWire® (1.09 ± 0.29 mm, p = 0.85), TigerTape® (1.39 ± 0.29 mm, p = 0.08), and LabralTape® (1.20 ± 0.33 mm, p = 0.41). The highest elongation was seen with Ultrabraid® (1.91 ± 0.34 mm); this value was statistically significantly greater than the results for all other suture materials except Orthocord® (1.59 mm ± 0.31 mm, p = 0.46) and Magnum Wire® (1.43 ± 0.25 mm, p = 0.14). Load to failure was highest for TigerTape® (287.43 ± 41.15 N), and this result was statistically significantly different than the results for all other sutures except LabralTape® (271.34 ± 48.48 N, p = 0.99) and TigerWire® (251.03 ± 25.8 N, p = 0.51). Stiffness was highest for LabralTape® (195.77 ± 49.06 N/mm), and this result was statistically significantly different than the results for all other sutures except TigerWire® (186.49 ± 19.83 N/ mm, p = 0.45) and TigerTape® (173.35 ± 15.60 N/mm, p = 0.19). The majority of sutures failed by pullout (n = 46, 51%) or tearing (n = 40, 45%). Conclusion: Suture design and material affect the biomechanical behavior of porcine meniscal-suture specimens. LabralTape®, TigerWire®, and TigerTape® demonstrated better overall combinations of low elongation, high maximum load to failure, and high stiffness.

Abstract

Background: Repair of a meniscal tear is indicated in certain conditions. Despite extensive research on the biomechanics of various repair methods, there has been minimal investigation of whether the suture material influences the meniscal-suture construct. The purpose of this study was to compare the biomechanical properties of nine different suture materials under cyclic and load-to-failure conditions. Methods: Ninety porcine menisci were randomly allocated to simple suture placement using either Ultrabraid®, Ultratape®, Magnum Wire®, TigerWire®, TigerTape®, LabralTape®, Orthocord®, 0 FiberWire®, or 2-0 FiberWire®. Each suture-meniscus specimen underwent cyclic loading followed by load-to-failure testing. Elongation, maximum load to failure, stiffness, and mode of failure were recorded and compared between each suture type using nonparametric testing. Mean ± standard deviation was reported and the statistical significance was p < 0.05. Results: Elongation during cyclic loading was lowest with 2-0 FiberWire (0.95 ± 0.17 mm); this value was statistically significantly different than the results for all other sutures except 0 FiberWire® (1.09 ± 0.17 mm, p = 0.79), TigerWire® (1.09 ± 0.29 mm, p = 0.85), TigerTape® (1.39 ± 0.29 mm, p = 0.08), and LabralTape® (1.20 ± 0.33 mm, p = 0.41). The highest elongation was seen with Ultrabraid® (1.91 ± 0.34 mm); this value was statistically significantly greater than the results for all other suture materials except Orthocord® (1.59 mm ± 0.31 mm, p = 0.46) and Magnum Wire® (1.43 ± 0.25 mm, p = 0.14). Load to failure was highest for TigerTape® (287.43 ± 41.15 N), and this result was statistically significantly different than the results for all other sutures except LabralTape® (271.34 ± 48.48 N, p = 0.99) and TigerWire® (251.03 ± 25.8 N, p = 0.51). Stiffness was highest for LabralTape® (195.77 ± 49.06 N/mm), and this result was statistically significantly different than the results for all other sutures except TigerWire® (186.49 ± 19.83 N/ mm, p = 0.45) and TigerTape® (173.35 ± 15.60 N/mm, p = 0.19). The majority of sutures failed by pullout (n = 46, 51%) or tearing (n = 40, 45%). Conclusion: Suture design and material affect the biomechanical behavior of porcine meniscal-suture specimens. LabralTape®, TigerWire®, and TigerTape® demonstrated better overall combinations of low elongation, high maximum load to failure, and high stiffness.

참고문헌 (40)

  1. Hede A, "Epidemiology of meniscal lesions in the knee. 1,215 open operations in Copenhagen 1982-84", Acta Orthop Scand, 61(5), pp.435~437 (1990)
  2. Choi SH, "The MRI findings of meniscal root tear of the medial meniscus : emphasis on coronal, sagittal and axial images", Knee Surg Sports Traumatol Arthrosc, 20, pp.2098~2103 (2012)
  3. Han SB, "Unfavorable results of partial meniscectomy for complete posterior medial meniscus root tear with early osteoarthritis : a 5-to 8-year follow-up study", Arthroscopy, 26, pp.1326~1332 (2010)
  4. Robertson DD, "Meniscal root injury and spontaneous osteonecrosis of the knee : an observation", J Bone Joint Surg(Br), 91, pp.190~195 (2009)
  5. Sung JH, "Meniscal extrusion and spontaneous osteonecrosis with root tear of medial meniscus : comparison with horizontal tear", Arthroscopy, 29, pp.726~732 (2013)
  6. Allaire R, "Biomechanical consequences of a tear of the posterior root of the medial meniscus", Similar to total meniscectomy. J Bone Joint Surg Am, 90, pp.1922~1931 (2008)
  7. Forkel P, "Biomechanical consequences of a posterior root tear of the lateral meniscus : stabilizing effect of the meniscofemoral ligament", Arch Orthop Trauma Surg, 133, pp.621~626 (2013)
  8. Kim JG, "Tibiofemoral contact mechanics following posterior root of medial meniscus tear, repair, meniscectomy, and allograft transplantation", Knee Surg Sports Traumatol Arthrosc, 21, pp.2121~2125 (2013)
  9. Marzo JM, "Effects of medial meniscus posterior horn avulsion and repair on tibiofemoral contact area and peak contact pressure with clinical implications", Am J Sports Med, 37, pp.124~129 (2009)
  10. Schillhammer CK, "Repair of lateral meniscus posterior horn detachment lesions : a biomechanical evaluation", Am J Sports Med, 40, pp.2604~2609 (2012)
  11. Ahn JH, "Double transosseous pull out suture technique for transection of posterior horn of medial meniscus", Arch Orthop Trauma Surg, 129, pp.387~392 (2009)
  12. Ahn JH, "A pull out suture for transection of the posterior horn of the medial meniscus: using a posterior trans-septal portal", Knee Surg Sports Traumatol Arthrosc, 15, pp.1510~1513 (2007)
  13. Forkel P, "Posterior root tear fixation of the lateral meniscus combined with arthroscopic ACL double-bundle reconstruction:technical note of a transosseous fixation using the tibial PL tunnel", Arch Orthop Trauma Surg, 132, pp.387~391 (2012)
  14. Harner CD, "Biomechanical consequences of a tear of the posterior root of the medial meniscus. Surgical technique", J Bone Joint Surg Am, 91(Suppl 2), pp.257~270 (2009)
  15. Moon HK, "Prognostic factors of arthroscopic pull-out repair for a posterior root tear of the medial meniscus", Am J Sports Med, 40, pp.1138~1143 (2012)
  16. Feucht MJ, "Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears", Knee Surg Sports Traumatol Arthrosc, 23, pp.132~139 (2015)
  17. Kim YM, "Pullout failure strength of the posterior horn of the medial meniscus with root ligament tear", Knee Surg Sports Traumatol Arthrosc, 21, pp.1546~1552 (2013)
  18. Kopf S, "Meniscal root suturing techniques : implications for root fixation", Am J Sports Med, 39, pp.2141~2146 (2011)
  19. Rosslenbroich SB, "Root tear of the meniscus : biomechanical evaluation of an arthroscopic refixation technique", Arch Orthop Trauma Surg, 133, pp.111~115 (2013)
  20. Bisson LJ, "A biomechanical comparison of the pullout strength of No. 2 FiberWire suture and 2-mm FiberWire tape in bovine rotator cuff tendons", Arthroscopy, 26, pp.1463~1468 (2010)
  21. Bisson LJ, "Influence of suture material on the biomechanical behavior of suture-tendon specimens : a controlled study in bovine rotator cuff", Am J Sports Med, 36, pp.907~912 (2008)
  22. Herbort M, "Strategies for repair of radial tears close to the meniscal rim—biomechanical analysis with a cyclic loading protocol", Am J Sports Med, 38, pp.2281~2287 (2010)
  23. Jaspers P, "The mechanical function of the meniscus, experiments on cadaveric pig knee-joints", Acta Orthop Belg, 46, pp.663~668 (1980)
  24. Lee YH, "Cyclic test comparison of allinside device and inside-out sutures for radial meniscus lesion repair : an in vitro porcine model study", Arthroscopy, 28, pp.1873~1881 (2012)
  25. Post WR, "Load to failure of common meniscal repair techniques : effects of suture technique and suture material", Arthroscopy, 13, pp.731~736 (1997)
  26. Zantop T, "Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios : biomechanical evaluation using a cyclic loading protocol", Am J Sports Med, 34, pp.799~805 (2006)
  27. Zantop T, "Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors : biomechanical evaluation of new meniscus refixation systems", Am J Sports Med, 32, pp.863~869 (2004)
  28. Zantop T, "Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bonepatellar tendon-bone grafts", Arthroscopy, 21, pp.934~941 (2005)
  29. Ma CB, "Biomechanical evaluation of arthroscopic rotator cuff repairs : double-row compared with single-row fixation", J Bone Joint Surg Am, 88, pp.403~410 (2006)
  30. Ma CB, "Biomechanical evaluation of arthroscopic rotator cuff stitches", J Bone Joint Surg Am, 86-A, pp.1211~1216 (2004)
  31. Stringtheory: an examination of the properties of “high strength” suture materials, "Jhamb A", University of New South Wales, Prince of Wales Hospital, ~ (2007)
  32. "DePuy Synthes Mitek Sports Medicine. Orthocord™ Product Information" (2015)[URL]
  33. Stärke C, "The effect of a nonanatomic repair of the meniscal horn attachment on meniscal tension : a biomechanical study", Arthroscopy, 26, pp.358~365 (2010)
  34. Lerer DB, "The role of meniscal root pathology and radial meniscal tear in medial meniscal extrusion", Skelet Radiol, 33, pp.569~574 (2004)
  35. Stärke C, "Tensile forces at the porcine anterior meniscal horn attachment", J Orthop Res, 27, pp.1619~1624 (2009)
  36. Burkhart SS, "Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure must the knot be?", Arthroscopy, 16, pp.202~207 (2000)
  37. Burkhart SS, "Loop security as a determinant of tissue fixation security", Arthroscopy, 14, pp.773~776 (1998)
  38. Wüst DM, "Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures", Arthroscopy, 22, pp.1146~1153 (2006)
  39. Lee YH, "Repair of peripheral vertical meniscus lesions in porcine menisci : in vitro biomechanical testing of 3different meniscus repair devices", Am J Sports Med, 41, pp.1074~1081 (2013)
  40. Aşík M, "Failure strength of repair devices versus meniscus suturing techniques", Knee Surg Sports Traumatol Arthrosc, 10, pp.25~29 (2002)

이 간행물의 다른 논문 (63건)