본문 바로가기
KERD
논문KCI 등재

Optimization of energy compensation layered structure of Geiger- Müller counters

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

The dose rate measured by Geiger-Müller (GM) detectors plays a crucial role in assessing radiation fields. Due to the inherent characteristics of GM tubes, the energy response is inconsistent across different types or energies of radiation, leading to significant discrepancies in dose rates for radiation of the same intensity. This paper addresses the energy response differences of GM tubes and improves the spatial design of the compensation structure based on traditional shielding compensation methods. Incorporating a multi-layer compensation material model improved the uniformity of energy response across different energy levels. Monte Carlo simulations validated that the designed compensation model effectively enhances the accuracy of GM tube measurements. Initially, a perforated design was used, which improved the relative energy response by three times compared to the traditional segmented compensation method. Additionally, after applying layered compensation optimization to the lead shielding model with the perforated design, the compensation effect was further increased by 20.3 %. The final root mean square error (RMSE) of 0.429 indicates that the improved energy compensation method significantly enhances the measurement performance of GM detectors, providing more design models and optimization directions for improving the energy response of dosimeters.

Abstract

The dose rate measured by Geiger-Müller (GM) detectors plays a crucial role in assessing radiation fields. Due to the inherent characteristics of GM tubes, the energy response is inconsistent across different types or energies of radiation, leading to significant discrepancies in dose rates for radiation of the same intensity. This paper addresses the energy response differences of GM tubes and improves the spatial design of the compensation structure based on traditional shielding compensation methods. Incorporating a multi-layer compensation material model improved the uniformity of energy response across different energy levels. Monte Carlo simulations validated that the designed compensation model effectively enhances the accuracy of GM tube measurements. Initially, a perforated design was used, which improved the relative energy response by three times compared to the traditional segmented compensation method. Additionally, after applying layered compensation optimization to the lead shielding model with the perforated design, the compensation effect was further increased by 20.3 %. The final root mean square error (RMSE) of 0.429 indicates that the improved energy compensation method significantly enhances the measurement performance of GM detectors, providing more design models and optimization directions for improving the energy response of dosimeters.

관련 논문AI추천

Ambient dose equivalent monitoring in the vicinity of a nuclear facility with dosemeters based on Geiger-Müller tubesĐaletić Miloš, Komatina Ivana, Kržanović Nikola, Radumilo Vesna, Živanović Miloš한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호Towards a better understanding of detection properties of different types of plastic scintillator crystals using physical detector and MCNPX codeAkkus Baki, Alan Hatice Yilmaz, ALMisned Ghada, Ilhan Taha Batuhan, Susam Lidya Amon, Tekin H.O., Yilmaz Ayberk한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제12호A novel directional radiation monitoring system for real-time nuclide identification and source localization using DOI method강주완, 백민규, 이성연, 정용현, 정윤수한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제10호Geant4 comprehensive evaluation of polystyrene-tungsten (VI) oxide composites for gamma and neutron radiation shielding enhancementAkhdar Hanan, Aminu Bashir Garba, Kipkosgei C Amos, Liu Yong-Kuo한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템의 설계라승탁, 이승호, 이주현한국전기전자학회 · 전기전자학회논문지2017 · 제21권 제2호Exploration of deep-learning-based dose rate estimation model for a large-volume plastic scintillation detector문명국, 전병일, 황지성한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제1호

이 간행물의 다른 논문 (49건)