본문 바로가기
KERD
논문KCI 등재

Optimization and experiment of supercritical helium flow in cryopump

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Large built-in cryopumps are widely used in nuclear fusion devices, the cryopumps studied in the paper are mainly used to provide a vacuum environment for beam generation and transmission. The cryopump is cooled by forced flow, so the supercritical helium flow heat transfer of the cryopump is investigated, the thermal load of the crysorbent panels of the unit pumping structure is calculated and analyzed by ANSYS Steady Thermal State software, meanwhile the supercritical helium flow heat transfer is simulated by ANSYS Fluent software, then the pressure drop of the fluid, temperature and flow uniformity are analyzed in different flow channels. The results show that the parallel structure with a tube diameter of 17.2 mm can reduce the pressure drop of the flow channel to 4.9E4 Pa, and the inlet velocity of the left and right branches are 1.96 m/s and 2.02 m/s, respectively, and the flow distribution is uniform, while the temperature field meets the requirements of the cryogenic pump. Finally, the model and calculation method are verified by using the laboratory cryopump, the simulation results coincide with the experimental results, which verifies the reliability of the simulation.

Abstract

Large built-in cryopumps are widely used in nuclear fusion devices, the cryopumps studied in the paper are mainly used to provide a vacuum environment for beam generation and transmission. The cryopump is cooled by forced flow, so the supercritical helium flow heat transfer of the cryopump is investigated, the thermal load of the crysorbent panels of the unit pumping structure is calculated and analyzed by ANSYS Steady Thermal State software, meanwhile the supercritical helium flow heat transfer is simulated by ANSYS Fluent software, then the pressure drop of the fluid, temperature and flow uniformity are analyzed in different flow channels. The results show that the parallel structure with a tube diameter of 17.2 mm can reduce the pressure drop of the flow channel to 4.9E4 Pa, and the inlet velocity of the left and right branches are 1.96 m/s and 2.02 m/s, respectively, and the flow distribution is uniform, while the temperature field meets the requirements of the cryogenic pump. Finally, the model and calculation method are verified by using the laboratory cryopump, the simulation results coincide with the experimental results, which verifies the reliability of the simulation.

관련 논문AI추천

Analysis and optimization of LN2 two-phase flow in CRAFT NNBI cryopumpHong Huihui, Li Bin, Tian Kun, Wang Fang, Wang Qianxu, Xie Yuanlai, Zhu Yang한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제2호Thermodynamic simulation and structural optimization of the collimator in the drift duct of EAST-NBICui Zhi-Wei, Hu Chun-dong, Jiang Yao, Pan Zhuo, Tang Ning, Wei Jiang-long, Xie Jun-Wei, Xie Yuan-lai한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제11호Three-dimensional thermal-hydraulics/neutronics coupling analysis on the full-scale module of helium-cooled tritium-breeding blanketBu Shanshan, Lian Qiang, Pan Liangming, Qiu Suizheng, Su G.H., Sun Wan, Tang Simiao, Tian Wenxi, Wang Xiaoyu, Wu Xinghua, Zhang Luteng, Zhu Longxiang한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제11호Electromagnetic-thermal two-way coupling analysis and application on helium-cooled solid blanketChen Hongli, Wang Shuai, Zhang Kefan한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제3호Thermal analysis and optimization of the new ICRH antenna Faraday Screen in EASTLiang Q.C., Liu L.N., Mao Y.Z., Qin C.M., Wang Y.S., Yang H., Yuan S., Zhang W., Zhang X.J.한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제7호Cryogenic flow behavior in porous media with experimental approach권재성, 김범수, 양정현, 최성웅한국마린엔지니어링학회 · 한국마린엔지니어링학회지2018 · 제42권 제10호

이 간행물의 다른 논문 (59건)