초록

Purpose: The purpose of this study was to analyze the influence of rotational alignment of the femoral and patellar components on patellar tilt after total knee arthroplasty (TKA).Materials and Methods: A total of 56 patients (76 knees) who underwent TKA using Advance Medial Pivot Knee system between May 2009 and April 2011 and were available for minimum 1-year follow-up were enrolled in this study. Whiteside’s line and the transepicondylar line were used to determine the rotational alignment of the femoral component. Patella cut was aimed to be parallel to the anterior patellar cortex during surgery. Radiographic evaluation was performed using plain axial radiographs. The rotational alignment of the femoral component was measured as the angle between the anterior condylar axis and the surgical transepicondylar axis. The patellar resection angle was measured between the patellar resection axis and the anterior cortical line of the patella. Patellar tilt was evaluated to investigate the correlation with the rotation of the femoral component and patellar resection angle. Results: The mean rotation of the femoral component was 0.42o±3.18o of internal rotation. The mean patellar resection angle was 1.82o±3.44o, indicating medial overresection. The mean patellar tilt was 6.12o±4.31o of lateral tilt. The rotational angle of the femoral component showed a negative correlation with patellar tilt in the linear regression analysis (p=0.749), but the patellar resection angle showed a positive correlation with patellar tilt (p<0.001).Conclusions: Accurate patellar resection is recommended for proper patellar tracking in TKA.

Abstract

Purpose: The purpose of this study was to analyze the influence of rotational alignment of the femoral and patellar components on patellar tilt after total knee arthroplasty (TKA).Materials and Methods: A total of 56 patients (76 knees) who underwent TKA using Advance Medial Pivot Knee system between May 2009 and April 2011 and were available for minimum 1-year follow-up were enrolled in this study. Whiteside’s line and the transepicondylar line were used to determine the rotational alignment of the femoral component. Patella cut was aimed to be parallel to the anterior patellar cortex during surgery. Radiographic evaluation was performed using plain axial radiographs. The rotational alignment of the femoral component was measured as the angle between the anterior condylar axis and the surgical transepicondylar axis. The patellar resection angle was measured between the patellar resection axis and the anterior cortical line of the patella. Patellar tilt was evaluated to investigate the correlation with the rotation of the femoral component and patellar resection angle. Results: The mean rotation of the femoral component was 0.42o±3.18o of internal rotation. The mean patellar resection angle was 1.82o±3.44o, indicating medial overresection. The mean patellar tilt was 6.12o±4.31o of lateral tilt. The rotational angle of the femoral component showed a negative correlation with patellar tilt in the linear regression analysis (p=0.749), but the patellar resection angle showed a positive correlation with patellar tilt (p<0.001).Conclusions: Accurate patellar resection is recommended for proper patellar tracking in TKA.

참고문헌 (21)

  1. Bindelglass DF, "Patellar tilt and subluxation in total knee arthroplasty. Relationship to pain, fixation, and design", Clin Orthop Relat Res, (286), pp.103~109 (1993)
  2. Berger RA, "Malrotation causing patellofemoral complications after total knee arthroplasty", Clin Orthop Relat Res, (356), pp.144~153 (1998)
  3. Lombardi AV Jr, "Fracture", dissociation of the polyethylene in metal-backed patellar components in total knee arthroplasty, 1988, pp.70, 675~679
  4. Anglin C, "Determinants of patellar tracking in total knee arthroplasty", Clin Biomech(Bristol, Avon), 23, pp.900~910 (2008)
  5. Miller MC, "Optimizing femoral component rotation in total knee arthroplasty", Clin Orthop Relat Res, (392), pp.38~45 (2001)
  6. Kawano T, "Factors affecting patellar tracking after total knee arthroplasty", J Arthroplasty, 17, pp.942~947 (2002)
  7. Chan KC, "Postoperative patellar tilt in total knee arthroplasty", J Arthroplasty, 14, pp.300~304 (1999)
  8. Komatsu T, "The effect of surgical approaches and tourniquet application on patellofemoral tracking in total knee arthroplasty", J Arthroplasty, 18, pp.308~312 (2003)
  9. Matsuda S, "Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees", Am J Knee Surg, 14, pp.152~156 (2001)
  10. Akagi M, "Effect of rotational alignment on patellar tracking in total knee arthroplasty", Clin Orthop Relat Res, (366), pp.155~163 (1999)
  11. Jae-Wook Jung, "슬관절 전치환술 후 대퇴 치환물의 회전각 및 슬개골 경사각과 임상 결과의 상관관계", Knee Surgery and Related Research, 23(2), pp.96~103 (2011), 대한슬관절학회
  12. Verlinden C, "The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait : an in vitro biomechanical study", J Bone Joint Surg Br, 92, pp.737~742 (2010)
  13. Varadarajan KM, "Are current total knee arthroplasty implants designed to restore normal trochlear groove anatomy?", J Arthroplasty, 26, pp.274~281 (2011)
  14. Indelli PF, "Contemporary femoral designs in total knee arthroplasty: effects on the patello-femoral congruence", Int Orthop, 36, pp.1167~1173 (2012)
  15. Kanekasu K, "Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty", Clin Orthop Relat Res, (434), pp.193~197 (2005)
  16. Gomes LS, "Patellar prosthesis positioning in total knee arthroplasty. A roentgenographic study", Clin Orthop Relat Res, (236), pp.72~81 (1988)
  17. Baldini A, "Patellofemoral evaluation after total knee arthroplasty : validation of a new weight-bearing axial radiographic view", J Bone Joint Surg Am, 89, pp.1810~1817 (2007)
  18. Nagamine R, "Patellar tracking measurement in the normal knee", J Orthop Res, 13, pp.115~122 (1995)
  19. Barrack RL, "Patella in total knee arthroplasty", Clin Orthop Relat Res, (389), pp.62~73 (2001)
  20. Ledger M, "Accuracy of patellar resection in total knee replacement. A study using the medial pivot knee", Knee, 12, pp.13~19 (2005)
  21. Belvedere C, "Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing", Knee Surg Sports Traumatol Arthrosc, 22, pp.1719~1727 (2014)

관련 논문AI추천

Rotational Alignment of Femoral Component for Minimal Medial Collateral Ligament Release in Total Knee ArthroplastyDoo Hoon Sun, Jae Yong Jung, Je Gyun Chon, Seong Won Jang, Tae In Kim대한슬관절학회 · Knee Surgery and Related Research2011 · 제23권 제3호Combined Rotational Alignment Change after Total Knee Arthroplasty in Different Tibial Component Designs: Implications for Optimal Tibial Component Rotational Alignment이승준, Jae Young Cho, Jeung Tak Suh, Kein Boon Poon, Seung Hyeon Jeung, Yoon Young Choi대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제1호Clinical Results Associated with Changes of Posterior Tibial Slope in Total Knee Arthroplasty김정한, 김창완, 민영경, 서승석대한슬관절학회 · Knee Surgery and Related Research2013 · 제25권 제1호Intraoperative patellar maltracking and postoperative radiographic patellar malalignment were more frequent in cases of complete medial collateral ligament release in cruciate-retaining total knee arthroplasty노정호, Kim Nam Yeop, Song Ki Ill대한슬관절학회 · Knee Surgery and Related Research2021 · 제33권 Internal rotational patellar resection and patella alta induced patellar maltracking in total knee arthroplasty: intraoperative measurement of the patellofemoral pressureHideki Murakami, Hiroo Shiraga, Masahiro Nozaki, Sakurako Kato, Sanshiro Yasuma, Takuya Usami, Yuji Joyo, Yuko Waguri‑Nagaya, Yusuke Hattori대한슬관절학회 · Knee Surgery and Related Research2024 · 제36권 Clinical Outcome of IM-Guided Total Knee Arthroplasty with Inappropriate Femoral Resection in Coronal Plane문영완, 서재곤, 이근호, 장성원, 한정훈대한슬관절학회 · Knee Surgery and Related Research2013 · 제25권 제1호

이 간행물의 다른 논문 (10건)