Closed Wedge Distal Femoral Osteotomy with a Polyaxial Locking Plate Designed for the Proximal Tibia: Minimum 5­-Year Outcomes

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Since distal femoral varus osteotomy (DFO) ­specific plates had not been available in Japan before 2015, we performed DFO using a plate for tibia. The purpose of this study was to elucidate the efficacy and problems associated with the non­specific plate in DFO. We used NCB­PT plates (Zimmer Inc.) in the upside­down position and the minimum 5­year outcomes were evaluated. The mean preoperative weight bearing line ratio and Japanese Orthopaedic Association score improved from 97.6%±35.8% and 68.0±11.5, respectively, to 44.0%±16.1% and 82.0±7.6, respectively, 1 year postoperatively and to 42.8%±15.7% and 86.0±8.2, respectively, 5 years postoperatively. The flexion range decreased from 149.0°±6.5° to 138.0°±5.7° 1 year postoperatively and to 135.0°±20.9° 5 years postoperatively. Although DFO using the NCB­PT plate provided mid­term benefits, it resulted in a loss of knee flexion, possibly due to excessive coverage of the medial femoral epicondyle.

Abstract

Since distal femoral varus osteotomy (DFO) ­specific plates had not been available in Japan before 2015, we performed DFO using a plate for tibia. The purpose of this study was to elucidate the efficacy and problems associated with the non­specific plate in DFO. We used NCB­PT plates (Zimmer Inc.) in the upside­down position and the minimum 5­year outcomes were evaluated. The mean preoperative weight bearing line ratio and Japanese Orthopaedic Association score improved from 97.6%±35.8% and 68.0±11.5, respectively, to 44.0%±16.1% and 82.0±7.6, respectively, 1 year postoperatively and to 42.8%±15.7% and 86.0±8.2, respectively, 5 years postoperatively. The flexion range decreased from 149.0°±6.5° to 138.0°±5.7° 1 year postoperatively and to 135.0°±20.9° 5 years postoperatively. Although DFO using the NCB­PT plate provided mid­term benefits, it resulted in a loss of knee flexion, possibly due to excessive coverage of the medial femoral epicondyle.

참고문헌 (10)

  1. Stahelin T, "Supracondylar osteotomy of the femur with use of compression. Osteosynthesis with a malleable implant", J Bone Joint Surg Am, 82, pp.712~722 (2000)
  2. Kosashvili Y, "Distal femoral varus osteotomy for lateral osteoarthritis of the knee : a minimum ten-year follow-up", Int Orthop, 34, pp.249~254 (2010)
  3. Jockel JA, "Minimally invasive and open surgical treatment of proximal tibia fractures using a polyaxial locking plate system : a prospective multi-centre study", Int Orthop, 37, pp.701~708 (2013)
  4. Takeuchi R, "Medial opening wedge high tibial osteotomy with early full weight bearing", Arthroscopy, 25, pp.46~53 (2009)
  5. Okuda M, "Validity and reliability of the Japanese Orthopaedic Association score for osteoarthritic knees", J Orthop Sci, 17, pp.750~756 (2012)
  6. Paley D, "Deformity planning for frontal and sagittal plane corrective osteotomies", Orthop Clin North Am, 25, pp.425~465 (1994)
  7. Seong-Dae Yoon, "Comparison of Cable Method and Miniaci Method Using Picture Archiving and Communication System in Preoperative Planning for Open Wedge High Tibial Osteotomy", Knee Surgery and Related Research, 28(4), pp.283~288 (2016), 대한슬관절학회
  8. Ranawat AS, "Total knee arthroplasty for severe valgus deformity", J Bone Joint Surg Am, 1, pp.271~284 (2005)
  9. Takeuchi R, "Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy : a new classification of lateral hinge fracture", Arthroscopy, 28, pp.85~94 (2012)
  10. Nakamura R, "The validity of the classification for lateral hinge fractures in open wedge high tibial osteotomy", Bone Joint J, 97, pp.1226~1231 (2015)

관련 논문AI추천

Distal Femoral Varus Osteotomy for Valgus Arthritis of the Knees: Systematic Review of Open versus Closed Wedge Osteotomy양재혁, Giorgio D.G. Delgado, Hyun Jung Kim, Jong Seong Lee, Ki Seong Kim, Kyung Wook Nha, Nikhil N Bhandare, Tulyapruek Tawonsawatruk, Yong Suk Chang, Young Chan Kim대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제1호Short-Term Results of Hybrid Closed-Wedge High Tibial Osteotomy: A Case Series with a Minimum 3-Year Follow-upHidetomo Saito, Hiroaki Kijima, Kimio Saito, Koji Nozaka, Naohisa Miyakoshi, Shin Yamada, Takahiro Sato, Toshiaki Yamamura, Yoichi Shimada대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제4호Postoperative change in patellofemoral alignment following closing-wedge distal femoral osteotomy performed for valgus osteoarthritic kneesAkaoka Yusuke, Iseki Tomoya, Kanto Ryo, Nakayama Hiroshi, Tensho Keiji, Yoshiya Shinichi대한슬관절학회 · Knee Surgery and Related Research2020 · 제32권 Distal Femoral Medial Opening Wedge Osteotomy for Post-Traumatic, Distal Femoral Varus Deformity서영진, 송시영, Koo-Hyun Jung, Myoung­Soo Cha대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제1호A Combined Closing Wedge Distal Femoral Osteotomy and Medial Reefing Procedure for Recurrent Patellar Dislocation with Genu Valgum권재호, 김영찬, 나경욱, 이종성, 장종범, Gautam M. Shetty연세대학교의과대학 · Yonsei Medical Journal2017 · 제58권 제4호Complications and Short-Term Outcomes of Medial Opening Wedge High Tibial Osteotomy Using a Locking Plate for Medial Osteoarthritis of the KneeDo-Hoon Kim, In-Seung Lee, Jin-Hyeok Seo, Ok-Gul Kim, Seung-Suk Seo, Youn-Gu Kim대한슬관절학회 · Knee Surgery and Related Research2016 · 제28권 제4호

이 간행물의 다른 논문 (12건)