This study presents the design, fabrication, and experimental validation of a shielding facility for the DD-108 neutron generator installed for active neutron interrogation applications such as differential die-away analysis. The shielding structure was optimized using MCNP6 simulations to meet regulatory dose limits of 20 mSv/y for radiation workers and 1 mSv/y for the general public. The regulatory dose limits were achieved by utilizing the existing concrete and lead structures and designing additional high density polyethylene shielding based on neutron and photon dose assessments. Various effective dose conversion coefficients were considered to ensure a conservative evaluation. The facility was constructed, and calibrated dosimeter measurements confirmed that neutron and photon doses were up to 50 % and 76 % lower than simulation predictions. These results reflect the conservative assumptions applied in the modeling, ensuring robust safety margins. The shielding facility met all licensing requirements, leading to the first regulatory approval of a DD-108 neutron generator in South Korea. This validation demonstrates the practicality of MCNP6-based shielding design and provides valuable insights for future neutron generator shielding applications.

Abstract

This study presents the design, fabrication, and experimental validation of a shielding facility for the DD-108 neutron generator installed for active neutron interrogation applications such as differential die-away analysis. The shielding structure was optimized using MCNP6 simulations to meet regulatory dose limits of 20 mSv/y for radiation workers and 1 mSv/y for the general public. The regulatory dose limits were achieved by utilizing the existing concrete and lead structures and designing additional high density polyethylene shielding based on neutron and photon dose assessments. Various effective dose conversion coefficients were considered to ensure a conservative evaluation. The facility was constructed, and calibrated dosimeter measurements confirmed that neutron and photon doses were up to 50 % and 76 % lower than simulation predictions. These results reflect the conservative assumptions applied in the modeling, ensuring robust safety margins. The shielding facility met all licensing requirements, leading to the first regulatory approval of a DD-108 neutron generator in South Korea. This validation demonstrates the practicality of MCNP6-based shielding design and provides valuable insights for future neutron generator shielding applications.

관련 논문AI추천

Shielding Evaluation and Activation Analysis of Facilities by Neutron Generator for the Development of 20 Feet Container Inspection System이진우, 정교성, 최대성(사)한국방사선산업학회 · 방사선산업학회지2023 · 제17권 제4호Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection곽성우, 김지수, 문지훈, 임경택, 정희준한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제9호Design and optimization of a source (reflector/shielding) performance test system based on (241Am-Be)-paraffin thermal neutron irradiation deviceAlSewaidan H., ElAgib I., Elsheikh Nassreldeen A.A., Kassim Hamoud A.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호Shielding analysis and optimization of IFMIF-DONES test cell floor bolt penetrations using MCNP and advanced variance reduction techniquesBreidokaite Simona, Stankunas Gediminas, Tidikas Andrius, Togobickij Benjaminas, Tuymurodov Dilmurod한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제8호Simple Calculation Method as a Supplementary Radiation Safety Assessment for Facility with Radiation Generator김상태한국콘텐츠학회 · International Journal of Contents2018 · 제14권 제4호고 에너지 양성자 가속기에서 생성되는 2차 방사선의 효과적인 차폐에 관한 연구김정훈, 배상일대한방사선과학회 · Journal of Radiological Science and Technology2020 · 제43권 제5호

이 간행물의 다른 논문 (59건)