본문 바로가기
KERD
논문KCI 등재

다전극 탐상을 통한 토중 매설배관 피복결함 탐상 정확도의 개선

Enhancing the Reliability of Coating Flaw Detection for Pipes Buried in Soil Using a Multi-Electrode Detector

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류금속공학

초록

External corrosion of buried pipes can be controlled using both coating and cathodic protection. However,deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detectionmethods is affected by interference such as metal objects connected to rectifiers and copper grids. Whenperforming parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potentialreversal in voltage gradient appears in the area where the interference exists. However, this area may benot identified using existing methods. The objective of this study was to determine the effect of analyzingdirection on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe wasrepeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coatingflaw detection was improved by up to 46.4% compared to the conventional method.

Abstract

External corrosion of buried pipes can be controlled using both coating and cathodic protection. However,deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detectionmethods is affected by interference such as metal objects connected to rectifiers and copper grids. Whenperforming parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potentialreversal in voltage gradient appears in the area where the interference exists. However, this area may benot identified using existing methods. The objective of this study was to determine the effect of analyzingdirection on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe wasrepeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coatingflaw detection was improved by up to 46.4% compared to the conventional method.

참고문헌 (38)

  1. Jung-Gu Kim, "Cathodic protection criteria of thermally insulated pipeline buried in soil", Corrosion Science, 43(11), pp.2011~2021 (2001), Elsevier BV[DOI]
  2. I. Gurrappa, "Cathodic protection of cooling water systems and selection of appropriate materials", Journal of Materials Processing Technology, 166(2), pp.256~267 (2005), Elsevier BV[DOI]
  3. Emad S Ibrahim, "Corrosion control in electric power systems", Electric Power Systems Research, 52(1), pp.9~17 (1999), Elsevier BV[DOI]
  4. 김기태, "REAL-TIME CORROSION CONTROL SYSTEM FOR CATHODIC PROTECTION OF BURIED PIPES FOR NUCLEAR POWER PLANT", CORROSION SCIENCE AND TECHNOLOGY, 14(1), pp.12~18 (2015), 한국부식방식학회[DOI]
  5. S. Srikanth, "Corrosion in a buried pressurised water pipeline", Engineering Failure Analysis, 12(4), pp.634~651 (2005), Elsevier BV[DOI]
  6. A Osella, "Currents induced by geomagnetic storms on buried pipelines as a cause of corrosion", Journal of Applied Geophysics, 38(3), pp.219~233 (1998), Elsevier BV[DOI]
  7. Ana Osella, "Effects of soil resistivity on currents induced on pipelines", Journal of Applied Geophysics, 44(4), pp.303~312 (2000), Elsevier BV[DOI]
  8. I.A. Metwally, "Factors affecting cathodic-protection interference", Engineering Analysis with Boundary Elements, 31(6), pp.485~493 (2007), Elsevier BV[DOI]
  9. Luiz C Wrobel, "Genetic algorithms for inverse cathodic protection problems", Engineering Analysis with Boundary Elements, 28(3), pp.267~277 (2004), Elsevier BV[DOI]
  10. R.A Gummow, "GIC effects on pipeline corrosion and corrosion control systems", Journal of Atmospheric and Solar-Terrestrial Physics, 64(16), pp.1755~1764 (2002), Elsevier BV[DOI]
  11. Plant Engineering: Evaluation of Indirect Assessment Techniques for Coating Flaw Detection, "E. Sisk", EPRI, 3~8, pp.Technical Report 1022962 (2011)
  12. M. E. Orazem, "Underground Pipeline Corrosion", pp.227~ (2014), Woodhead Publishing
  13. Y. B. Cho, , J. Corros. Sci. Soc. of Kor., 26, pp.400~ (1997)
  14. D. H. Boteler, , Proc. Corrosion 2013 Conf., pp.2522~ (2013), NACE International
  15. Zweni Masilela, "Using the direct current voltage gradient technology as a quality control tool during construction of new pipelines", Engineering Failure Analysis, 5(2), pp.99~104 (1998), Elsevier BV[DOI]
  16. M. Norm, , Mater. Performance, 52, pp.96~ (2013)
  17. 류영돈, "외면부식 직접평가법 개발 및 국내 도입 연구", 한국가스학회지, 18(5), pp.12~19 (2014), 한국가스학회[DOI]
  18. A. Smart, , Proc. Corrosion 2011 Conf. (2011), NACE International
  19. 김영식, "Effect of Applied Voltage on the Reliability of Coating Flaw Detection of Pipe with Different Buried Depths", CORROSION SCIENCE AND TECHNOLOGY, 18(6), pp.277~284 (2019), 한국부식방식학회[DOI]
  20. 박정훈, "MFL 비파괴 검사 시스템에서 다중 결함에 의한 신호 왜곡과 신호 보정에 관한 연구", 한국자기학회지, 26(1), pp.24~30 (2016), 한국자기학회
  21. Seolin Shin, "Risk-based underground pipeline safety management considering corrosion effect", Journal of Hazardous Materials, 342, pp.279~289 (2018), Elsevier BV[DOI]
  22. 류영돈, "고체기준전극 및 원격전위측정 시스템 개발에 관한 연구", 한국가스학회지, 19(3), pp.38~43 (2015), 한국가스학회[DOI]
  23. 김진준, "매설배관의 방식전위 측정시스템 개발에 관한 연구", 한국가스학회지, 18(5), pp.66~71 (2014), 한국가스학회[DOI]
  24. Shejuan Xie, "A novel magnetic force transmission eddy current array probe and its application for nondestructive testing of defects in pipeline structures", Sensors and Actuators A: Physical, 309, pp.112030~ (2020), Elsevier BV[DOI]
  25. 류영돈, "전압강하를 고려한 전기방식 기준 개정에 관한 연구", 한국가스학회지, 20(4), pp.50~57 (2016), 한국가스학회[DOI]
  26. K. J. Satsios, "Currents and voltages induced during earth faults in a system consisting of a transmission line and a parellel pipeline", European Transactions on Electrical Power, 8(3), pp.193~199 (1998), Wiley[DOI]
  27. Y. B. Cho, , Int. Pipeline Conf, 1, pp.463~ (1996)[DOI]
  28. M. Magura, "Experimental Research of Buried Pipelines", Procedia Engineering, 40, pp.50~55 (2012), Elsevier BV[DOI]
  29. Y. B. Cho, , J. Corros. Sci. Soc. of Kor., 24, pp.167~ (1995)
  30. K. S. Kim, , Journal of Power Engineering, 30(3), pp.116~ (2019)
  31. 장현영, "국내원전에 매설된 콜타르 코팅 배관의 음극방식과 FEM법을 이용한 방식성능 시뮬레이션", CORROSION SCIENCE AND TECHNOLOGY, 16(3), pp.115~127 (2017), 한국부식방식학회[DOI]
  32. H. Y. Chang, , Trans. Korean Soc. Press. Vessel. Pip, 11, pp.61~ (2015)[DOI]
  33. Y. Chao, , Corros. Rev, 37, pp.273~ (2019)[DOI]
  34. Z. G. Chen, , J. Natural Gas Sci. Eng, 15, pp.76~ (2013)[DOI]
  35. 김민기, "매설 배관 피복 결함 탐상 정확도에 미치는 인접 정류기 및 접지 구리망 간섭의 영향", CORROSION SCIENCE AND TECHNOLOGY, 19(4), pp.211~223 (2020), 한국부식방식학회[DOI]
  36. J. P. Nicholson, , Proc. Eurocorr 2010 Conf, pp.9145~ (2010)
  37. "DCVG Training Manual, DC-Voltage Gradient (DCVG)Surveys Using MCM’s Integrated Pipeline Survey Test Equipment and Database Management Package", pp.4~19 (2020), M. C. Miller Co
  38. Esmaeel Naderi, "A new equation proposed for evaluation of IR drop on buried pipelines", Anti-Corrosion Methods and Materials, 60(6), pp.312~318 (2013), Emerald[DOI]

관련 논문AI추천