본문 바로가기
KERD
논문KCI 등재

Open reduction and internal fixation using multiple nonabsorbable suture materials in acute patella fracture: comparison of clinical and radiological outcome with tension band wiring

0

조회

0

다운로드

0

인용

0

참고문헌

초록

For treating displaced patella fractures, tension band wiring is the most widely used technique. However, implant removal surgery is often necessary to alleviate discomfort caused by fixation materials. On the contrary, fixation using nonabsorbable suture materials is anticipated to result in comparable outcomes without need for further implant removal surgery. However, there is a lack of clinical studies comparing the two fixation techniques (wire and nonabsorbable suture materials) for acute patella fractures.From 2014 to 2018, we retrospectively reviewed 60 patients who underwent open reduction with internal fixation for acute patella fracture. Thirty patients (group 1) who received surgery using tension band wiring and 30 patients (group 2) who received surgery using nonabsorbable suture materials were enrolled. The average follow-up period was more than 1 year after operation. Operation time, postoperative bone union time, range of motion (ROM) of the knee joint, postoperative clinical results, and complications were compared between the two groups. Operation time, clinical bone union, and radiologic bone union were not statistically different between groups 1 and 2. At 3 months postoperatively, flexion was 120.3 ± 9.4° in group 1 and 110.5 ± 7.7° in group 2, showing statistically significant difference ( p = 0.037). At 6 and 12 months postoperatively, the ROM was similar in both groups. Hospital for special surgery score at 3 months postoperatively was 78.4 ± 8.2 in group 1 and 83.7 ± 8.7 in group 2, showing statistically significant differences ( p = 0.032). However, at 6 and 12 months postoperatively, there were no statistical differences. Lysholm score at 3 months postoperatively was 73.5 ± 8.1 in group 1 and 80.4 ± 8.2 in group 2, showing statistically significant difference ( p = 0.016), but at 6 and 12 months postoperatively, there were no statistical differences. Fixation using multiple nonabsorbable suture materials can be an alternative surgical method in managing patella fractures, along with tension band wiring.

Abstract

For treating displaced patella fractures, tension band wiring is the most widely used technique. However, implant removal surgery is often necessary to alleviate discomfort caused by fixation materials. On the contrary, fixation using nonabsorbable suture materials is anticipated to result in comparable outcomes without need for further implant removal surgery. However, there is a lack of clinical studies comparing the two fixation techniques (wire and nonabsorbable suture materials) for acute patella fractures.From 2014 to 2018, we retrospectively reviewed 60 patients who underwent open reduction with internal fixation for acute patella fracture. Thirty patients (group 1) who received surgery using tension band wiring and 30 patients (group 2) who received surgery using nonabsorbable suture materials were enrolled. The average follow-up period was more than 1 year after operation. Operation time, postoperative bone union time, range of motion (ROM) of the knee joint, postoperative clinical results, and complications were compared between the two groups. Operation time, clinical bone union, and radiologic bone union were not statistically different between groups 1 and 2. At 3 months postoperatively, flexion was 120.3 ± 9.4° in group 1 and 110.5 ± 7.7° in group 2, showing statistically significant difference ( p = 0.037). At 6 and 12 months postoperatively, the ROM was similar in both groups. Hospital for special surgery score at 3 months postoperatively was 78.4 ± 8.2 in group 1 and 83.7 ± 8.7 in group 2, showing statistically significant differences ( p = 0.032). However, at 6 and 12 months postoperatively, there were no statistical differences. Lysholm score at 3 months postoperatively was 73.5 ± 8.1 in group 1 and 80.4 ± 8.2 in group 2, showing statistically significant difference ( p = 0.016), but at 6 and 12 months postoperatively, there were no statistical differences. Fixation using multiple nonabsorbable suture materials can be an alternative surgical method in managing patella fractures, along with tension band wiring.

참고문헌 (15)

  1. Galla M, "Patella fractures", Chirurg, 76(10), pp.987~997 (2005)[DOI]
  2. Kumar G, "Implant removal following surgical stabilization of patella fracture", Orthopedics, 33(5), pp.301~ (2010)[DOI]
  3. Biddau F, "Migration of a broken cerclage wire from the patella into the heart. A case report", J Bone Joint Surg Am, 88(9), pp.2057~2059 (2006)[DOI]
  4. Carpenter JE, "Fractures of the patella", Instr Course Lect, 43, pp.97~108 (1994)
  5. Gardner MJ, "Complete exposure of the articular surface for fixation of patellar fractures", J Orthop Trauma, 19(2), pp.118~123 (2005)[DOI]
  6. Gosal HS, "Clinical experience of patellar fracture fixation using metal wire or non absorbable polyester—a study of 37cases", Injury, 32(2), pp.129~135 (2001)[DOI]
  7. Wu CC, "Patellar tension band wiring: a revised technique", Arch Orthop Trauma Surg, 121(1–2), pp.12~16 (2001)[DOI]
  8. Petrie J, "Complications of patellar fracture repair : treatment and results", J Knee Surg, 26(5), pp.309~312 (2013)[DOI]
  9. Monaco E, "Patellar fracture fixation using suture tape cerclage", Arthrosc Tech, 9(6), pp.783~789 (2020)[DOI]
  10. Wright PB, "FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures", Injury, 40(11), pp.1200~1203 (2009)[DOI]
  11. Camarda L, "Fiber-Wire tension band for patellar fractures", J Orthop Traumatol, 17(1), pp.75~80 (2016)[DOI]
  12. Buezo O, "Patellar fractures: an innovative surgical technique with transosseous suture to avoid implant removal", Surg Innov, 22(5), pp.474~478 (2015)[DOI]
  13. Baldini A, "A new patellofemoral scoring system for total knee arthroplasty", Clin Orthop Relat Res, 452, pp.150~154 (2006)[DOI]
  14. Tegner Y, "Rating systems in the evaluation of knee ligament injuries", Clin Orthop Relat Res, 198, pp.43~49 (1985)
  15. Camarda L, "Nonmetallic implant for patellar fracture fixation: a systematic review", Injury, 47(8), pp.1613~1617 (2016)[DOI]

이 간행물의 다른 논문 (46건)