화력발전소 배관시스템의 운전 및 기후조건에 따른 에너지절감에 관한 시뮬레이션

A simulation on the energy saving based on different temperature tracing method and weather condition in electrical power plant

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류수산학

초록

Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature aroundthe power plant area below 5。C to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplyingsystem is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measureof temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy canbe saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy savingrate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient airand three initial flowing water temperature inside the tube were used. The result shows that the temperature control system usingsensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energysaving rate is almost 75% in two days basis and even 83% in one day basis.

Abstract

Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature aroundthe power plant area below 5。C to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplyingsystem is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measureof temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy canbe saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy savingrate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient airand three initial flowing water temperature inside the tube were used. The result shows that the temperature control system usingsensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energysaving rate is almost 75% in two days basis and even 83% in one day basis.

참고문헌 (10)

  1. Baumeister T, "Marks’standard handbook for mechanical engineers", pp.6.1~6.196 (1978), McGraw-Hill
  2. Duffie JA, "Solar engineering of thermal processes", pp.22~135 (2000), John Wiley & Sons
  3. Faghri A, "Heat pipe science and technology", pp.41~55 (1995), Taylor & Francis
  4. Gerald C.F, "Applied Numerical Analysis", pp.25~45 (2002), Addison-Wesley Publishing Company
  5. Haberman R, "Elementary Applied Partial Differential Equations with Fourier Series and Boundary Value Problems", pp.1~15 (1983), Prentice Hall, Inc
  6. Holman JP, "Heat transfer", pp.26~47 (1997), McGraw-Hill
  7. Incropera FP, "Fundamentals of heat transfer", pp.136~141 (2013), John Wiley & Sons
  8. Kreith F, "Principles of heat transfer", pp.2001, Brooks
  9. Kreyszig E, "Advanced engineering mathematics", pp.46~99 (2011), John Wiley & Sons
  10. Myers GE, "Analytical methods in conduction heat transfer", pp.105~155 (2001), McGraw-Hill

관련 논문AI추천

이 간행물의 다른 논문 (9건)