Application of near-infrared spectroscopy for hay evaluation at different degrees of sample preparation
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective: A study was conducted to quantify the performance differences of the nearinfrared spectroscopy (NIRS) calibration models developed with different degrees of hay sample preparations.Methods: A total of 227 imported alfalfa (<i>Medicago sativa</i> L.) and another 360 imported timothy (<i>Phleum pratense</i> L.) hay samples were used to develop calibration models for nutrient value parameters such as moisture, neutral detergent fiber, acid detergent fiber, crude protein, and <i>in vitro</i> dry matter digestibility. Spectral data of hay samples prepared by milling into 1-mm particle size or unground were separately regressed against the wet chemistry results of the abovementioned parameters.Results: The performance of the developed NIRS calibration models was evaluated based on R<sup>2</sup>, standard error, and ratio percentage deviation (RPD). The models developed with ground hay were more robust and accurate than those with unground hay based on calibration model performance indexes such as R<sup>2</sup> (coefficient of determination), standard error, and RPD. Although the R<sup>2</sup> of calibration models was mainly greater than 0.90 across the feed value indexes, the R<sup>2</sup> of cross-validations was much lower. The R<sup>2</sup> of cross-validation varies depending on feed value indexes, which ranged from 0.61 to 0.81 in alfalfa, and from 0.62 to 0.95 in timothy. Estimation of feed values in imported hay can be achievable by the calibrated NIRS. However, the NIRS calibration models must be improved by including a broader range of imported hay samples in the modeling.Conclusion: Although the analysis accuracy of NIRS was substantially higher when calibration models were developed with ground samples, less sample preparation will be more advantageous for achieving rapid delivery of hay sample analysis results. Therefore, further research warrants investigating the level of sample preparations compromising analysis accuracy by NIRS.
Abstract
Objective: A study was conducted to quantify the performance differences of the nearinfrared spectroscopy (NIRS) calibration models developed with different degrees of hay sample preparations. Methods: A total of 227 imported alfalfa (Medicago sativa L.) and another 360 imported timothy (Phleum pratense L.) hay samples were used to develop calibration models for nutrient value parameters such as moisture, neutral detergent fiber, acid detergent fiber, crude protein, and in vitro dry matter digestibility. Spectral data of hay samples prepared by milling into 1-mm particle size or unground were separately regressed against the wet chemistry results of the abovementioned parameters. Results: The performance of the developed NIRS calibration models was evaluated based on R2 , standard error, and ratio percentage deviation (RPD). The models developed with ground hay were more robust and accurate than those with unground hay based on calibration model performance indexes such as R2 (coefficient of determination), standard error, and RPD. Although the R2 of calibration models was mainly greater than 0.90 across the feed value indexes, the R2 of cross-validations was much lower. The R2 of cross-validation varies depending on feed value indexes, which ranged from 0.61 to 0.81 in alfalfa, and from 0.62 to 0.95 in timothy. Estimation of feed values in imported hay can be achievable by the calibrated NIRS. However, the NIRS calibration models must be improved by including a broader range of imported hay samples in the modeling. Conclusion: Although the analysis accuracy of NIRS was substantially higher when calibration models were developed with ground samples, less sample preparation will be more advantageous for achieving rapid delivery of hay sample analysis results. Therefore, further research warrants investigating the level of sample preparations compromising analysis accuracy by NIRS.
참고문헌 (30)
- Kim JD, "Review of the current forage production, supply, and quality measure standard in South Korea", J Kor Grassl Forage Sci, 40, pp.149~155 (2020)[DOI]
- Ahmadi F, "In situ ruminal degradation characteristics of dry matter and crude protein of imported hays marketed to the Korean cattle industry : a field study", J Food Agric Environ, 15, pp.80~85 (2017)
- Lee BH, "A study on the distribution of feed value and quality grade of imported hay", J Kor Grassl Forage Sci, 40, pp.1~6
- Poppi DP, "The validity of the critical size theory for particles leaving the rumen", J Agric Sci, 94, pp.275~280 (1980)[DOI]
- Yakubu HG, "The recent advances of near-infrared spectroscopy in dairy production—a review", Crit Rev Food Sci Nutr, 62, pp.810~831 (2022)
- Murphy DJ, "A near infrared spectroscopy calibration for the prediction of fresh grass quality on Irish pastures", Inf Process Agric, 9, pp.243~253 (2021)[DOI]
- Norman HC, "Broad near-infrared spectroscopy calibrations can predict the nutritional value of >100 forage species within the Australian feedbase", Anim Prod Sci, 60, pp.1111~1122 (2020)[DOI]
- Cherney JH, "Handheld NIRS for forage evaluation", Comput Electron Agric, 190, pp.106469~ (2021)[DOI]
- Bremner JM, "Methods of soil analysis: part 3 chemical methods", pp.1085~1121 (1996), ASA, CSSA, and SSSA Books
- Van Soest PJ, "Methods for dietary fiber, neutral detergent fiber, and nonstarch polysaccharides in relation to animal nutrition", J Dairy Sci, 74, pp.3583~3597 (1991)[DOI]
- Goering HK, "Forage fiber analysis (apparatus, reagents, procedures, and some applications)" (1970), US Department Agriculture-Agricultural Research Service (USDA-ARS)
- Shenk JS, "Forage quality, evaluation, and utilization", pp.406~449 (1994), ASA, CSSA, and SSSA Books
- Guo T, "Measurements of chemical compositions in corn stover and wheat straw by near-infrared reflectance spectroscopy", Animals, 11, pp.3328~ (2021)[DOI]
- Karoui R, "Mid-infrared spectrometry : a tool for the determination of chemical parameters in Emmental cheeses produced during winter", Lait, 86, pp.83~97 (2006)[DOI]
- Yu P, "Effect of variety and maturity stage on chemical composition, carbohydrate and protein subfractions, in vitro rumen degradability and energy values of timothy and alfalfa", Can J Anim Sci, 83, pp.279~290 (2003)[DOI]
- Rego G, "A portable IoT NIR spectroscopic system to analyze the quality of dairy farm forage", Comput Electron Agric, 175, pp.105578~ (2020)[DOI]
- Berzaghi P, "Prediction performance of portable near infrared reflectance instruments using preprocessed dried, ground forage samples", Comput Electron Agric, 182, pp.106013~ (2021)[DOI]
- Vough LR, "Influence of soil moisture and ambient temperature on yield and quality of alfalfa forage", Agron J, 63, pp.40~42 (1971)[DOI]
- Prananto JA, "Near infrared(NIR)spectroscopy as a rapid and cost-effective method for nutrient analysis of plant leaf tissues", Adv Agron, 164, pp.1~49 (2020)[DOI]
- Campbell M, "The use of near-infrared and mid-infrared spectroscopy to rapidly measure the nutrient composition and the in vitro rumen dry matter digestibility of brown seaweeds", Anim Feed Sci Technol, 285, pp.115239~ (2022)[DOI]
- Stuth J, "Direct and indirect means of predicting forage quality through near infrared reflectance spectroscopy", Field Crops Res, 84, pp.45~56 (2003)[DOI]
- Barnes RJ, "Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra", Appl Spectrosc, 43, pp.772~777 (1989)[DOI]
- Andueza D, "NIRS prediction of the feed value of temperate forages : efficacy of four calibration strategies", Animal, 5, pp.1002~1013 (2011)[DOI]
- Roberts CA, "Near infrared-spectroscopy in agriculture", pp.229~408 (2003), Agronomy Monographs
- Cozzolino D, "Determination of dry matter and crude protein contents of undried forages by near-infrared reflectance spectroscopy", J Sci Food Agric, 82, pp.380~384 (2002)[DOI]
- Brogna N, "Technical note : near infrared reflectance spectroscopy to predict fecal indigestible neutral detergent fiber for dairy cows", J Dairy Sci, 101, pp.1234~1239 (2018)[DOI]
- Yang Z, "Development and validation of near-infrared spectroscopy for the prediction of forage quality parameters in Lolium multiflorum", Peer J, 5, pp.e3867~ (2017)[DOI]
- Workman JJ Jr, "Handbook of near-infrared analysis", pp.141~168 (2007), CRC Press
- Buxton DR, "Errors in forage-quality data predicted by near infrared reflectance spectroscopy", Crop Sci, 31, pp.212~218 (1991)[DOI]
- Lundberg KM, "Prediction of forage energy content by near infrared reflectance spectroscopy and summative equations", Prof Anim Sci, 20, pp.262~269 (2004)[DOI]
